Junyi Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junyi Yin has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Bozhi Tian
The James Franck Institute, University of Chicago, Chicago, USA
2 shared publications - Chuanwang Yang
The James Franck Institute, The University of Chicago, Chicago, USA
2 shared publications - Jing Zhang
The James Franck Institute, University of Chicago, Chicago, USA
2 shared publications - Naisong Shan
University of Chicago
2 shared publications - Pengju Li
The James Franck Institute, University of Chicago, Chicago, USA
2 shared publications - Sihong Wang
University of Chicago
2 shared publications
Latest Publications
- Open Access
- 20 August 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Host-guest design for stretchable light-emitting polymers reaching an EQE of 20%
Stretchable light-emitting devices are poised to play a central role in advancing human–technology integration, enabling applications such as on-skin displays, optical sensing, and implantable phototherapy. Among them, stretchable organic light-emitting diodes (OLEDs) are particularly attractive due to their high efficiency and potential biocompatibility. The recent realization of thermally activated delayed fluorescence (TADF) in stretchable emitters, enabling triplet exciton harvesting, has increased external quantum efficiency (EQE) to 10%. However, triplet–triplet annihilation (TTA) remains a key barrier to further improvement toward commercial-grade performance. Here, we introduce a stretchable host–guest emitter design that overcomes this quenching mechanism by uniformly dispersing TADF small-molecule guests within a newly designed stretchable host polymer. This architecture enables efficient exciton transfer while suppressing TTA, yielding an external quantum efficiency (EQE) of 20.3%—doubling the performance of prior state-of-the-art. Notably, the guest molecules also act as plasticizers, enhancing stretchability beyond 150%. With generalizability to different TADF emitters, this work establishes a foundational strategy for mitigating TTA in stretchable emissive layers, advancing soft optoelectronics toward commercial viability with mechanical durability and practicality.
- 20 August 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessHost-guest design for stretchable light-emitting polymers reaching an EQE of 20%
Stretchable light-emitting devices are poised to play a central role in advancing human–technology integration, enabling applications such as on-skin displays, optical sensing, and implantable phototherapy. Among them, stretchable organic light-emitting diodes (OLEDs) are particularly attractive due to their high efficiency and potential biocompatibility. The recent realization of thermally activated delayed fluorescence (TADF) in stretchable emitters, enabling triplet exciton harvesting, has increased external quantum efficiency (EQE) to 10%. However, triplet–triplet annihilation (TTA) remains a key barrier to further improvement toward commercial-grade performance. Here, we introduce a stretchable host–guest emitter design that overcomes this quenching mechanism by uniformly dispersing TADF small-molecule guests within a newly designed stretchable host polymer. This architecture enables efficient exciton transfer while suppressing TTA, yielding an external quantum efficiency (EQE) of 20.3%—doubling the performance of prior state-of-the-art. Notably, the guest molecules also act as plasticizers, enhancing stretchability beyond 150%. With generalizability to different TADF emitters, this work establishes a foundational strategy for mitigating TTA in stretchable emissive layers, advancing soft optoelectronics toward commercial viability with mechanical durability and practicality.
- 31 July 2025
- Published by MyJove Corporation
- No. 221,p. e68305
JoVE Video Dataset
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 31 July 2025
- Published by MyJove Corporation
- No. 221,p. e68305
JoVE Video Dataset
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 18 July 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 221,p. e68305
Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- 18 July 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 221,p. e68305
Bidirectional Electrical and Optoelectronic Interfaces in Healthy and Ischemic Ex Vivo Rat Hearts
Electrophysiological studies are pivotal in exploring interactions between materials and cardiac biointerfaces. Recent advancements have introduced various novel conductor and semiconductor materials for bidirectional interfaces with cardiac models, facilitating low-intensity pacing alongside high spatiotemporal and high signal-to-noise ratio (SNR) recordings. The ex vivo rodent heart model serves as an effective platform for validating the functionalities of new materials and devices, bridging in vitro findings to translational insights while minimizing ethical and administrative concerns. In this protocol, we detail the isolation and ex vivo perfusion of adult rat hearts using a Langendorff apparatus, establishing precise bidirectional stimulation and recording with high-performance semiconductors and conductors, including nanoporous silicon, nanoporous carbon, and flexible mesh-like microelectrode arrays. Additionally, we present a myocardial infarction model induced by ischemia-reperfusion (I/R) injury, assessed through multichannel recording and mapping as well as infarct staining, enabling cardiac disease-relevant studies and potential therapeutic explorations. This methodology offers valuable insights into materials-bio interface research and the development of next-generation cardiac bioelectronics.
- Open Access
- 24 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Large-scale stretchable neuromorphic circuits for on-body edge processing of sensory data
The rapid development of intrinsically stretchable electronics for use on the human bodies and robots has significantly enhanced the ability to collect multi-modal data at high spatiotemporal resolutions, over extended periods, and across diverse body locations. This progress has generated a growing demand for enhanced computing capabilities to process sensory data, making near-sensor edge computing an attractive solution. Stretchable organic electrochemical transistors (OECTs) have been demonstrated to be as a viable platform for integrating neuromorphic edge computing functions into these human-interfaced systems. However, the lack of a scalable fabrication method for stretchable OECT arrays and circuits has limited the achievable computing complexity. Here, we address this limitation through synergistic innovations in material designs and device fabrication processes, enabling large-scale, intrinsically stretchable OECT arrays with a high density of up to 10,000 transistors per cm2. These OECT devices exhibit good synaptic performance in terms of linear, precise, and repeatable programming of conductance states, as well as a good retention time. With high performance uniformity at these integration levels, we have unprecedentedly utilized a stretchable circuit to achieve the hardware implementation of artificial neural network (ANN) for processing health data, including physiological data for heart-attack risk assessment and kernel convolution for locating propagation wavefronts in cardiac ventricular fibrillation. Additionally, we explored the potential of implementing reinforcement learning algorithms for robotic applications.
- 24 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessLarge-scale stretchable neuromorphic circuits for on-body edge processing of sensory data
The rapid development of intrinsically stretchable electronics for use on the human bodies and robots has significantly enhanced the ability to collect multi-modal data at high spatiotemporal resolutions, over extended periods, and across diverse body locations. This progress has generated a growing demand for enhanced computing capabilities to process sensory data, making near-sensor edge computing an attractive solution. Stretchable organic electrochemical transistors (OECTs) have been demonstrated to be as a viable platform for integrating neuromorphic edge computing functions into these human-interfaced systems. However, the lack of a scalable fabrication method for stretchable OECT arrays and circuits has limited the achievable computing complexity. Here, we address this limitation through synergistic innovations in material designs and device fabrication processes, enabling large-scale, intrinsically stretchable OECT arrays with a high density of up to 10,000 transistors per cm2. These OECT devices exhibit good synaptic performance in terms of linear, precise, and repeatable programming of conductance states, as well as a good retention time. With high performance uniformity at these integration levels, we have unprecedentedly utilized a stretchable circuit to achieve the hardware implementation of artificial neural network (ANN) for processing health data, including physiological data for heart-attack risk assessment and kernel convolution for locating propagation wavefronts in cardiac ventricular fibrillation. Additionally, we explored the potential of implementing reinforcement learning algorithms for robotic applications.