Xianglun Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xianglun Wei has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Peng Ma
Shandong Provincial Key Laboratory of Nuclear Science, Nuclear Energy Technology and Comprehensive Utilization, School of Nuclear Science, Energy and Power Engineering, Shandong University, Jinan 250061
5 shared publications - Herun Yang
School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049
3 shared publications - Hooi Jin Ong
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000
3 shared publications - J. B. Ma
State Key Laboratory of Heavy Ion Science and Technology, Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000
3 shared publications - Zaihong Yang
Peking University
3 shared publications - Bing-Feng Lv
Institute of Modern Physics
2 shared publications
Latest Publications
- Open Access
- 5 September 2026
- Published by Elsevier in Physics Letters B
- Vol. 881
Z = 6 magicity in 15C and 14B revealed by the 2H (15C, 3He)14B reaction
- 5 September 2026
- Published by Elsevier in Physics Letters B
- Vol. 881
Open AccessZ = 6 magicity in 15C and 14B revealed by the 2H (15C, 3He)14B reaction
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , E06001
Erratum: Development and application of position-sensitive double parallel-plate avalanche counter
- 1 June 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (06) , E06001
Erratum: Development and application of position-sensitive double parallel-plate avalanche counter
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , P05019
Development and application of position-sensitive double parallel-plate avalanche counter
Double parallel-plate avalanche counters (DPPACs), each comprising two PPACs with delay-line readout for two-dimensional position determination, have been developed at Institute of Modern Physics, Chinese Academy of Sciences. The detector was tested with a standard α source, achieving a position resolution of about 0.4 mm. Each PPAC measures particle hit positions in two dimensions, with the dual configuration enhancing overall detection efficiency. Two DPPACs were deployed in a month-long experimental campaign at the Radioactive Ion Beam Line in Lanzhou (RIBLL1) with secondary beams of 10 Be and 10,11,16 C, and faint 18 O primary beam at typical intensities of 1.2–1.5 × 10 5 Hz, yielding a stable single DPPAC-detection efficiency > 90% and a typical in-beam position resolution ≈ 0.56 mm. This successful deployment addresses a critical domestic need for reliable, high-resolution beam monitoring and establishes a robust technological foundation for future experiments.
- 1 May 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (05) , P05019
Development and application of position-sensitive double parallel-plate avalanche counter
Double parallel-plate avalanche counters (DPPACs), each comprising two PPACs with delay-line readout for two-dimensional position determination, have been developed at Institute of Modern Physics, Chinese Academy of Sciences. The detector was tested with a standard α source, achieving a position resolution of about 0.4 mm. Each PPAC measures particle hit positions in two dimensions, with the dual configuration enhancing overall detection efficiency. Two DPPACs were deployed in a month-long experimental campaign at the Radioactive Ion Beam Line in Lanzhou (RIBLL1) with secondary beams of 10 Be and 10,11,16 C, and faint 18 O primary beam at typical intensities of 1.2–1.5 × 10 5 Hz, yielding a stable single DPPAC-detection efficiency > 90% and a typical in-beam position resolution ≈ 0.56 mm. This successful deployment addresses a critical domestic need for reliable, high-resolution beam monitoring and establishes a robust technological foundation for future experiments.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , T11004
Evaluating position and energy resolution of time projection chamber using alpha sources
To carry out the charge exchange reaction experiments in inverse kinematics, a Time Projection Chamber (TPC) based on the Thick Gas Electron Multiplier was constructed. This paper focuses on evaluating its position and energy measurement capabilities with the α radiation sources. For position resolution, the dependencies on drift distance and scattering angle were investigated. In the x -direction, position resolution was consistently better than 400 μm across various drift distances. In the z -direction, it remained better than 300 μm for different drift distances and scattering angles. For energy measurement, the resolution for ∼5 MeV α particles was approximately 8% (FWHM) and the good linearity in energy response was exhibited. The tests demonstrated that the TPC's performance in measuring the position and energy of charged particles like α particles is adequate to satisfy the requirements for future experiments aimed at the extraction of track information and energy deposition.
- 1 November 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (11) , T11004
Evaluating position and energy resolution of time projection chamber using alpha sources
To carry out the charge exchange reaction experiments in inverse kinematics, a Time Projection Chamber (TPC) based on the Thick Gas Electron Multiplier was constructed. This paper focuses on evaluating its position and energy measurement capabilities with the α radiation sources. For position resolution, the dependencies on drift distance and scattering angle were investigated. In the x -direction, position resolution was consistently better than 400 μm across various drift distances. In the z -direction, it remained better than 300 μm for different drift distances and scattering angles. For energy measurement, the resolution for ∼5 MeV α particles was approximately 8% (FWHM) and the good linearity in energy response was exhibited. The tests demonstrated that the TPC's performance in measuring the position and energy of charged particles like α particles is adequate to satisfy the requirements for future experiments aimed at the extraction of track information and energy deposition.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09020
Simulation of radiation environment for the beam monitor of CEE experiment
The cooling storage ring external-target experiment is a large-scale nuclear physics experiment, which aims to study the physics of heavy-ion collisions at low temperatures and high baryon densities. A beam monitor (BM) is placed in the beam line to monitor the beam status and to improve the reconstruction resolution of the primary vertices. The radiation dose and particle fluence stemming from the beam interactions with gases and detector materials affect the performance of the sensors and electronics of BM. This paper uses FLUKA Monte Carlo code to simulate the radiation environment of BM detector. Radiation quantities including the total ionizing dose, 1 MeV neutron equivalent fluence, high-energy hadron flux, thermal neutron flux, and nuclear fragment flux are presented. Results of alternative simulation setups, including adding shielding layers inside the BM, are also investigated.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09020
Simulation of radiation environment for the beam monitor of CEE experiment
The cooling storage ring external-target experiment is a large-scale nuclear physics experiment, which aims to study the physics of heavy-ion collisions at low temperatures and high baryon densities. A beam monitor (BM) is placed in the beam line to monitor the beam status and to improve the reconstruction resolution of the primary vertices. The radiation dose and particle fluence stemming from the beam interactions with gases and detector materials affect the performance of the sensors and electronics of BM. This paper uses FLUKA Monte Carlo code to simulate the radiation environment of BM detector. Radiation quantities including the total ionizing dose, 1 MeV neutron equivalent fluence, high-energy hadron flux, thermal neutron flux, and nuclear fragment flux are presented. Results of alternative simulation setups, including adding shielding layers inside the BM, are also investigated.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07047
Design and performance of the prototype gaseous beam monitor with GEM and pixel sensors for the CSR external-target experiment
A gaseous beam monitor utilizing gas electron multiplier (GEM) and pixel sensors is being developed for the Cooling Storage Ring (CSR) External-target Experiment (CEE) at Heavy Ion Research Facility in Lanzhou (HIRFL). The beam monitor is mainly used to track each beam particle, providing an accurate reconstruction of the primary vertex of the collision. Two generations of the pixel sensors (named Topmetal-CEE) were produced, with the second generation's performance improving over the first one. The design and performance of the prototype are described in the paper. Characterization of the prototype with heavy-ion beams and laser beams are presented, showing a spatial resolution better than 50 μm and a time resolution better than 15 ns.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , C07047
Design and performance of the prototype gaseous beam monitor with GEM and pixel sensors for the CSR external-target experiment
A gaseous beam monitor utilizing gas electron multiplier (GEM) and pixel sensors is being developed for the Cooling Storage Ring (CSR) External-target Experiment (CEE) at Heavy Ion Research Facility in Lanzhou (HIRFL). The beam monitor is mainly used to track each beam particle, providing an accurate reconstruction of the primary vertex of the collision. Two generations of the pixel sensors (named Topmetal-CEE) were produced, with the second generation's performance improving over the first one. The design and performance of the prototype are described in the paper. Characterization of the prototype with heavy-ion beams and laser beams are presented, showing a spatial resolution better than 50 μm and a time resolution better than 15 ns.