Majd Mzeihem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Majd Mzeihem has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Farid Amirouche
Department of Orthopaedic Surgery, University of Illinois at Chicago, Chicago, Illinois, USA
7 shared publications - Ali Rteil2 shared publications
- Hristo Piponov2 shared publications
- Jason Lee Koh
System Physician Executive and Chair, Orthopaedic & Spine Institute, Endeavor Health, Evanston IL, USA
2 shared publications - Lalit Puri2 shared publications
- Yazdan Raji
Department of Orthopaedic Surgery, University of Illinois at Chicago , 835 S. Wolcott Ave., Room E-270, Chicago, IL 60612
2 shared publications
Latest Publications
- 13 August 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
Robotic-Assisted Total Hip Arthroplasty Is Associated With Lower Prosthetic Complications in Patients With Lumbar Fusion or Stiff Spine: A Propensity-Matched Cohort Study
Background: Patients with spinopelvic risk factors such as lumbar fusion or stiff spine exhibit a 5- to 10-fold increased risk of dislocation following total hip arthroplasty (THA), primarily due to altered spinopelvic mechanics that influence cup positioning. The utilization of robotic-assisted THA facilitates personalized planning, enhancing component placement in this high-risk population. This study aims to compare rates of implant-related and medical complications between robotic-assisted and manual THA in these high-risk patients. Methods: Data were retrospectively obtained from the TriNetX Research Network. Patients with prior lumbar fusion or spinal conditions associated with stiffness or malalignment, and who subsequently underwent THA, were identified using ICD-10 and CPT codes. Procedure codes defined robotic-assisted and manual THA. After 1:1 propensity score matching for age, sex, body mass index, smoking status, and other comorbidities, outcomes were compared at 3, 6, 12 months and 2 years. A subgroup analysis compared both groups in spinal fusion (SF) and nonfusion (no-SF/stiff spine) patients. Results: After 1:1 propensity score matching, each cohort included 2,147 patients. At 3 months, robotic THA was associated with lower prosthetic complications (1.4 vs 2.7%; odds ratio [OR]: 1.86, 95%; P = 0.01) and postoperative blood transfusion (0.9 vs. 1.8%; OR: 2.02, P = 0.01). At 1 year, dislocation was reduced (0.9 vs. 1.8%; OR: 2.07; P = 0.01). Revisions were also lower at 1 and 2-year follow-up in the robotic group (1.7 vs. 2.7%, OR: 1.61; 2.0 vs 3.7%, OR: 1.86; all P < 0.05; respectively), and the manual group had 1.9 times the hazard of having revision surgery at 2 years (HR: 1.9, 95%; P = 0.02). In no-SF patients, robotic THA was associated with markedly lower rates of prosthetic complications and revision surgery. Conclusion: Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA. Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.
- 13 August 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
Robotic-Assisted Total Hip Arthroplasty Is Associated With Lower Prosthetic Complications in Patients With Lumbar Fusion or Stiff Spine: A Propensity-Matched Cohort Study
Background: Patients with spinopelvic risk factors such as lumbar fusion or stiff spine exhibit a 5- to 10-fold increased risk of dislocation following total hip arthroplasty (THA), primarily due to altered spinopelvic mechanics that influence cup positioning. The utilization of robotic-assisted THA facilitates personalized planning, enhancing component placement in this high-risk population. This study aims to compare rates of implant-related and medical complications between robotic-assisted and manual THA in these high-risk patients. Methods: Data were retrospectively obtained from the TriNetX Research Network. Patients with prior lumbar fusion or spinal conditions associated with stiffness or malalignment, and who subsequently underwent THA, were identified using ICD-10 and CPT codes. Procedure codes defined robotic-assisted and manual THA. After 1:1 propensity score matching for age, sex, body mass index, smoking status, and other comorbidities, outcomes were compared at 3, 6, 12 months and 2 years. A subgroup analysis compared both groups in spinal fusion (SF) and nonfusion (no-SF/stiff spine) patients. Results: After 1:1 propensity score matching, each cohort included 2,147 patients. At 3 months, robotic THA was associated with lower prosthetic complications (1.4 vs 2.7%; odds ratio [OR]: 1.86, 95%; P = 0.01) and postoperative blood transfusion (0.9 vs. 1.8%; OR: 2.02, P = 0.01). At 1 year, dislocation was reduced (0.9 vs. 1.8%; OR: 2.07; P = 0.01). Revisions were also lower at 1 and 2-year follow-up in the robotic group (1.7 vs. 2.7%, OR: 1.61; 2.0 vs 3.7%, OR: 1.86; all P < 0.05; respectively), and the manual group had 1.9 times the hazard of having revision surgery at 2 years (HR: 1.9, 95%; P = 0.02). In no-SF patients, robotic THA was associated with markedly lower rates of prosthetic complications and revision surgery. Conclusion: Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA. Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.
- 4 August 2026
- Published by SAGE Publications in HAND
Fingertip Forces and Thenar Pressure During Instrument Use in Simulated Meniscectomy: A Comparative Study of Rongeur and Forceps
Background: Hand-intensive surgical tasks expose the thumb and surrounding musculature to repetitive mechanical loading. Instrument design may influence the distribution of forces across the hand, yet quantitative data characterizing these loads during routine orthopedic procedures remain limited. This study quantified fingertip forces and thenar pressure during simulated meniscectomy using a pituitary rongeur and Ferris-Smith forceps. Methods: Orthopedic residents performed simulated meniscectomy on a porcine knee model while wearing TekScan pressure sensors. Each participant used both a pituitary rongeur and Ferris-Smith forceps. The rongeur employs a pistol-grip mechanism producing thenar loading, whereas the forceps use a pincer-style grip emphasizing distal thumb–index finger motion. The TekScan Grip System quantified force distribution across the fingers, thumb tip, and thenar region. Results: Thirteen residents completed 4 meniscectomies each. The use of the pituitary rongeur resulted in significantly higher mean forces in the fingers (50.10 ± 6.22 N vs 30.62 ± 5.69 N) and thenar region (40.69 ± 11.99 N vs 3.34 ± 1.39 N) compared with forceps. Thumb-tip forces were similar between instruments (7.66 ± 3.85 N for rongeur vs 10.59 ± 3.15 N for forceps). Linear regression revealed no significant associations between demographic variables and force measurements, except for thumb-tip force during forceps use. Conclusion: Instrument design significantly affects hand force distribution during meniscectomy. The rongeur imposes substantially greater mechanical demands on the fingers and thenar region, whereas forceps rely primarily on distal thumb–index finger motion. Repetitive rongeur use may contribute to cumulative hand and thumb carpometacarpal strain in surgeons.
- 4 August 2026
- Published by SAGE Publications in HAND
Fingertip Forces and Thenar Pressure During Instrument Use in Simulated Meniscectomy: A Comparative Study of Rongeur and Forceps
Background: Hand-intensive surgical tasks expose the thumb and surrounding musculature to repetitive mechanical loading. Instrument design may influence the distribution of forces across the hand, yet quantitative data characterizing these loads during routine orthopedic procedures remain limited. This study quantified fingertip forces and thenar pressure during simulated meniscectomy using a pituitary rongeur and Ferris-Smith forceps. Methods: Orthopedic residents performed simulated meniscectomy on a porcine knee model while wearing TekScan pressure sensors. Each participant used both a pituitary rongeur and Ferris-Smith forceps. The rongeur employs a pistol-grip mechanism producing thenar loading, whereas the forceps use a pincer-style grip emphasizing distal thumb–index finger motion. The TekScan Grip System quantified force distribution across the fingers, thumb tip, and thenar region. Results: Thirteen residents completed 4 meniscectomies each. The use of the pituitary rongeur resulted in significantly higher mean forces in the fingers (50.10 ± 6.22 N vs 30.62 ± 5.69 N) and thenar region (40.69 ± 11.99 N vs 3.34 ± 1.39 N) compared with forceps. Thumb-tip forces were similar between instruments (7.66 ± 3.85 N for rongeur vs 10.59 ± 3.15 N for forceps). Linear regression revealed no significant associations between demographic variables and force measurements, except for thumb-tip force during forceps use. Conclusion: Instrument design significantly affects hand force distribution during meniscectomy. The rongeur imposes substantially greater mechanical demands on the fingers and thenar region, whereas forceps rely primarily on distal thumb–index finger motion. Repetitive rongeur use may contribute to cumulative hand and thumb carpometacarpal strain in surgeons.
- 31 July 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (21) , e3133-e3143
Implant-Related Complications After Robotic-Assisted Versus Manual Revision Knee Arthroplasty: A Propensity-Matched Cohort Study
Introduction: As robotic-assisted total knee arthroplasty (TKA) gains traction in revision procedures, the urgent need to investigate its effectiveness compared with manual methods becomes apparent. Methods: Data were retrospectively obtained from the TriNetX Collaborative Network. Revision TKA (rKA) cases were identified using CPT codes and categorized as manual or robotic assisted using ICD-10 procedure codes. Cohorts were balanced with 1:1 propensity score matching for demographics, comorbidities, and revision history. Complication rates were compared across follow-up using chi-square analysis. Results: An initial query identified 19,088 manual and 2,709 robotic-assisted rKA cases. After 1:1 propensity matching, 2,010 patients remained in each group. Robotic rKA had significantly lower mechanical implant‑related complications at 3 and 6 months (OR 1.67 and 1.66; P < 0.001) and lower early VTE, while PJI, readmission, and revision rates were not significantly different. Manual rKA showed higher opioid use at 0 to 3 months (OR 1.40, 95% CI, 1.14 to 1.71, P < 0.001) and 3 to 6 months (OR 1.28, 95% CI, 1.12 to 1.47, P < 0.001) and throughout the 3 years of follow-up.Throughout the follow-up period, patellar dislocation, wound infection, non‑implant-related complications, and transfusion did not differ. At 1 year, manual rKA had higher instability (OR 1.59; P = 0.001) and higher hazard of mechanical implant‑related complications (HR 1.52, 95% CI, 1.32 to 1.75; P = 0.049). Instability, loosening, and periprosthetic fracture remained higher at 2 to 3 years, and revision was significantly more frequent at 3 years (13.5% vs. 11.4%; OR 1.22, 95% CI, 1.02 to 1.46; P = 0.03). Discussion: Robotic-assisted rKA was associated with markedly lower mechanical implant‑related complications across early and midterm follow-up, including reduced rates of instability, aseptic loosening, periprosthetic fracture, VTE, and lower opioid requirements. Rates of PJI, readmission, and revision were largely comparable, although manual rKA demonstrated a markedly higher revision rate by 3 years. These findings suggest that robotic assistance may improve implant reliability and postoperative recovery, but prospective studies and cost-effectiveness analyses remain necessary.
- 31 July 2026
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (21) , e3133-e3143
Implant-Related Complications After Robotic-Assisted Versus Manual Revision Knee Arthroplasty: A Propensity-Matched Cohort Study
Introduction: As robotic-assisted total knee arthroplasty (TKA) gains traction in revision procedures, the urgent need to investigate its effectiveness compared with manual methods becomes apparent. Methods: Data were retrospectively obtained from the TriNetX Collaborative Network. Revision TKA (rKA) cases were identified using CPT codes and categorized as manual or robotic assisted using ICD-10 procedure codes. Cohorts were balanced with 1:1 propensity score matching for demographics, comorbidities, and revision history. Complication rates were compared across follow-up using chi-square analysis. Results: An initial query identified 19,088 manual and 2,709 robotic-assisted rKA cases. After 1:1 propensity matching, 2,010 patients remained in each group. Robotic rKA had significantly lower mechanical implant‑related complications at 3 and 6 months (OR 1.67 and 1.66; P < 0.001) and lower early VTE, while PJI, readmission, and revision rates were not significantly different. Manual rKA showed higher opioid use at 0 to 3 months (OR 1.40, 95% CI, 1.14 to 1.71, P < 0.001) and 3 to 6 months (OR 1.28, 95% CI, 1.12 to 1.47, P < 0.001) and throughout the 3 years of follow-up.Throughout the follow-up period, patellar dislocation, wound infection, non‑implant-related complications, and transfusion did not differ. At 1 year, manual rKA had higher instability (OR 1.59; P = 0.001) and higher hazard of mechanical implant‑related complications (HR 1.52, 95% CI, 1.32 to 1.75; P = 0.049). Instability, loosening, and periprosthetic fracture remained higher at 2 to 3 years, and revision was significantly more frequent at 3 years (13.5% vs. 11.4%; OR 1.22, 95% CI, 1.02 to 1.46; P = 0.03). Discussion: Robotic-assisted rKA was associated with markedly lower mechanical implant‑related complications across early and midterm follow-up, including reduced rates of instability, aseptic loosening, periprosthetic fracture, VTE, and lower opioid requirements. Rates of PJI, readmission, and revision were largely comparable, although manual rKA demonstrated a markedly higher revision rate by 3 years. These findings suggest that robotic assistance may improve implant reliability and postoperative recovery, but prospective studies and cost-effectiveness analyses remain necessary.
- Open Access
- 23 March 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (3)
Comparison of All-Inside Suture Implant Versus Suture Hook Technique for Meniscal Ramp Lesions: A Systematic Review and Meta-analysis
Background: Ramp lesions, tears at the posteromedial meniscocapsular junction, often accompany anterior cruciate ligament injuries and compromise stability. The all-inside repair is gaining popularity for its minimally invasive approach, though comparative data with suture hook (SH) repair remain limited. Purpose: To compare clinical outcomes of all-inside suture implant (SI) versus SH repair technique for ramp lesions. Study Design: Systematic review; Level of evidence, 3. Methods: A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses)-guided search of PubMed, EMBASE, Cochrane Library, and Google Scholar identified studies comparing all-inside SI versus SH repair for ramp lesions. Two reviewers independently screened, extracted data, and assessed quality with the Risk Of Bias in Non-Randomized Studies–of Interventions. Pooled mean differences and odds ratios (ORs) were calculated, with heterogeneity evaluated by Q-test and I 2 , applying random-effects models when appropriate. Results: Five studies (2 case-control and 3 cohorts) with 901 patients were included; 388 underwent all-inside SI repair. The mean age was 28.71 years, with follow-up ranging from 12 to 24 months. There was a significant difference in overall repair failure between groups, with 99 failures out of 388 cases (25.5%) in the all-inside SI group compared with 55 failures out of 513 cases (10.7%) in the SH group (OR, 2.36; P < .01). Specifically, all-inside SI repair demonstrated a greater likelihood of secondary meniscectomy (OR, 2.40). Postoperative International Knee Documentation Committee, Tegner, Lysholm, and return-to-sport rates showed no significant differences. Preoperative laxity >7 mm and age ≤20 years did not significantly affect failure risk. Conclusion: SI repair for ramp lesions shows higher failure and secondary meniscectomy rates than SH repair. Functional outcomes appear largely comparable between the 2 repair techniques. Results should be interpreted cautiously, as outcomes depend on surgical technique, visualization, suture configuration, and rehabilitation. More high-quality studies are needed to define the optimal repair method.
- 23 March 2026
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 14 (3)
Open AccessComparison of All-Inside Suture Implant Versus Suture Hook Technique for Meniscal Ramp Lesions: A Systematic Review and Meta-analysis
Background: Ramp lesions, tears at the posteromedial meniscocapsular junction, often accompany anterior cruciate ligament injuries and compromise stability. The all-inside repair is gaining popularity for its minimally invasive approach, though comparative data with suture hook (SH) repair remain limited. Purpose: To compare clinical outcomes of all-inside suture implant (SI) versus SH repair technique for ramp lesions. Study Design: Systematic review; Level of evidence, 3. Methods: A PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses)-guided search of PubMed, EMBASE, Cochrane Library, and Google Scholar identified studies comparing all-inside SI versus SH repair for ramp lesions. Two reviewers independently screened, extracted data, and assessed quality with the Risk Of Bias in Non-Randomized Studies–of Interventions. Pooled mean differences and odds ratios (ORs) were calculated, with heterogeneity evaluated by Q-test and I 2 , applying random-effects models when appropriate. Results: Five studies (2 case-control and 3 cohorts) with 901 patients were included; 388 underwent all-inside SI repair. The mean age was 28.71 years, with follow-up ranging from 12 to 24 months. There was a significant difference in overall repair failure between groups, with 99 failures out of 388 cases (25.5%) in the all-inside SI group compared with 55 failures out of 513 cases (10.7%) in the SH group (OR, 2.36; P < .01). Specifically, all-inside SI repair demonstrated a greater likelihood of secondary meniscectomy (OR, 2.40). Postoperative International Knee Documentation Committee, Tegner, Lysholm, and return-to-sport rates showed no significant differences. Preoperative laxity >7 mm and age ≤20 years did not significantly affect failure risk. Conclusion: SI repair for ramp lesions shows higher failure and secondary meniscectomy rates than SH repair. Functional outcomes appear largely comparable between the 2 repair techniques. Results should be interpreted cautiously, as outcomes depend on surgical technique, visualization, suture configuration, and rehabilitation. More high-quality studies are needed to define the optimal repair method.
- 3 March 2026
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 51 (4) , 405.e1-405.e9
Surgical Management of Wrist Arthritis Is Linked to Increased Carpal Tunnel Syndrome/Carpal Tunnel Release Risk: Rethinking Preoperative Evaluation
- 3 March 2026
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 51 (4) , 405.e1-405.e9
Surgical Management of Wrist Arthritis Is Linked to Increased Carpal Tunnel Syndrome/Carpal Tunnel Release Risk: Rethinking Preoperative Evaluation
- 19 December 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (5) , 377-383
Fluoroscopy-Guided Lateral Tibial Plateau Fracture Fixation with and without Needle Arthroscopy
Background: Articular depression, especially in central tibial plateau segments, is surgically challenging. According to the 10-segment classification, the anterolateral approach visualizes only 36.6% of the tibial plateau. The aim of this study was to compare biomechanical performance between fluoroscopy-guided fixation techniques with and without needle arthroscopy. Methods: This cadaveric study used 16 knee specimens with standardized lateral tibial plateau fractures. Specimens were randomized to fluoroscopy-guided (FG) or fluoroscopy plus needle arthroscopy-guided (FNG) reduction performed via an anterolateral approach. Kirschner wires and proximal tibial plates were used for fixation. The primary outcome was load to failure. Secondary outcomes included stress, strain, stiffness, reduction quality, radiation exposure, and operative time. Results: Sixteen cadaveric specimens (9 right knees; 12 males) were studied. The FG group had greater mean articular depression (1.77 versus 1.69 mm) and step-off (2.44 versus 2.26 mm) than the FNG group. The FNG group had a higher mean load to failure (1,784 versus 1,063 N), whereas the FG group had greater mean stiffness (170.34 versus 130.82 N/mm) and a longer mean operative time (1,662 versus 1,524 seconds). The FG group also demonstrated higher mean fluoroscopic doses and larger differences in condylar width and the medial tibial plateau angle than the FNG group. Conclusions: FNG reduction improved articular congruity and load to failure in lateral tibial plateau fractures without increasing operative time, supporting needle arthroscopy as a valuable adjunct for managing complex articular fractures with less invasive exposure. Clinical Relevance: This study is clinically relevant because it shows that incorporating needle arthroscopy during fixation of lateral tibial plateau fractures can improve reduction quality and stability without prolonging operative time.
- 19 December 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 108 (5) , 377-383
Fluoroscopy-Guided Lateral Tibial Plateau Fracture Fixation with and without Needle Arthroscopy
Background: Articular depression, especially in central tibial plateau segments, is surgically challenging. According to the 10-segment classification, the anterolateral approach visualizes only 36.6% of the tibial plateau. The aim of this study was to compare biomechanical performance between fluoroscopy-guided fixation techniques with and without needle arthroscopy. Methods: This cadaveric study used 16 knee specimens with standardized lateral tibial plateau fractures. Specimens were randomized to fluoroscopy-guided (FG) or fluoroscopy plus needle arthroscopy-guided (FNG) reduction performed via an anterolateral approach. Kirschner wires and proximal tibial plates were used for fixation. The primary outcome was load to failure. Secondary outcomes included stress, strain, stiffness, reduction quality, radiation exposure, and operative time. Results: Sixteen cadaveric specimens (9 right knees; 12 males) were studied. The FG group had greater mean articular depression (1.77 versus 1.69 mm) and step-off (2.44 versus 2.26 mm) than the FNG group. The FNG group had a higher mean load to failure (1,784 versus 1,063 N), whereas the FG group had greater mean stiffness (170.34 versus 130.82 N/mm) and a longer mean operative time (1,662 versus 1,524 seconds). The FG group also demonstrated higher mean fluoroscopic doses and larger differences in condylar width and the medial tibial plateau angle than the FNG group. Conclusions: FNG reduction improved articular congruity and load to failure in lateral tibial plateau fractures without increasing operative time, supporting needle arthroscopy as a valuable adjunct for managing complex articular fractures with less invasive exposure. Clinical Relevance: This study is clinically relevant because it shows that incorporating needle arthroscopy during fixation of lateral tibial plateau fractures can improve reduction quality and stability without prolonging operative time.
- Open Access
- 10 October 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-13
Assessing resident participation and its effect on postoperative complications in intertrochanteric and femoral neck fractures: insights on orthopaedic residency training in the USA—A NSQIP retrospective study
Introduction: The global incidence of hip fractures continues to rise with an aging population. In the USA, orthopedic residency programs prioritize surgical mentorship to prepare trainees for independent practice. However, the impact of resident involvement on patient outcomes, particularly complications following hip fracture fixation, remains unclear. This study evaluates whether resident participation in intertrochanteric and femoral neck fracture surgical treatments only influences postoperative complication rates. Materials and Methods: We retrospectively analyzed de-identified data from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) from 2005 to 2012. A total of 6300 patients who underwent hip fracture fixation were identified using ICD-9-CM codes, after excluding incomplete cases. Patients were divided into two cohorts: procedures performed by attending surgeons alone (AA) and those with resident involvement (AR). Groups were matched using propensity score analysis. Postoperative complications were compared using multivariate logistic regression, adjusting for potential confounders. Results: In the AR group, 45.0% of patients experienced at least one complication, compared to 29.3% in the AA group. The AR group had higher rates of postoperative transfusions and systemic complications, including sepsis. Wound dehiscence and organ space infections were significantly more common in the AR group ( P < 0.02). Additionally, the AR group demonstrated longer operation times, extended anesthesia-to-incision intervals, and prolonged hospital stays. When stratified by fracture type, intertrochanteric fractures were associated with significantly higher complication rates compared to femoral neck fractures in the AR group ( P < 0.001). Despite these findings, multivariate regression analysis revealed no significant difference in the rate of serious complications; including cardiopulmonary, neurologic, infectious, renal, and mortality events; between groups. Conclusion: Resident involvement in hip fracture fixation is associated with increased overall complication rates, particularly in intertrochanteric fractures, but does not significantly affect the incidence of serious complications. These findings highlight opportunities to improve resident training, particularly in surgical efficiency, patient positioning, hemostasis, closure technique, and perioperative care, to better prepare residents for independent surgical practice.
- 10 October 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-13
Open AccessAssessing resident participation and its effect on postoperative complications in intertrochanteric and femoral neck fractures: insights on orthopaedic residency training in the USA—A NSQIP retrospective study
Introduction: The global incidence of hip fractures continues to rise with an aging population. In the USA, orthopedic residency programs prioritize surgical mentorship to prepare trainees for independent practice. However, the impact of resident involvement on patient outcomes, particularly complications following hip fracture fixation, remains unclear. This study evaluates whether resident participation in intertrochanteric and femoral neck fracture surgical treatments only influences postoperative complication rates. Materials and Methods: We retrospectively analyzed de-identified data from the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) from 2005 to 2012. A total of 6300 patients who underwent hip fracture fixation were identified using ICD-9-CM codes, after excluding incomplete cases. Patients were divided into two cohorts: procedures performed by attending surgeons alone (AA) and those with resident involvement (AR). Groups were matched using propensity score analysis. Postoperative complications were compared using multivariate logistic regression, adjusting for potential confounders. Results: In the AR group, 45.0% of patients experienced at least one complication, compared to 29.3% in the AA group. The AR group had higher rates of postoperative transfusions and systemic complications, including sepsis. Wound dehiscence and organ space infections were significantly more common in the AR group ( P < 0.02). Additionally, the AR group demonstrated longer operation times, extended anesthesia-to-incision intervals, and prolonged hospital stays. When stratified by fracture type, intertrochanteric fractures were associated with significantly higher complication rates compared to femoral neck fractures in the AR group ( P < 0.001). Despite these findings, multivariate regression analysis revealed no significant difference in the rate of serious complications; including cardiopulmonary, neurologic, infectious, renal, and mortality events; between groups. Conclusion: Resident involvement in hip fracture fixation is associated with increased overall complication rates, particularly in intertrochanteric fractures, but does not significantly affect the incidence of serious complications. These findings highlight opportunities to improve resident training, particularly in surgical efficiency, patient positioning, hemostasis, closure technique, and perioperative care, to better prepare residents for independent surgical practice.
- Open Access
- 1 September 2025
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 10 (9) , 660-670
Exploring superior capsular reconstruction and tendon transfers for massive irreparable posterosuperior rotator cuff tears
Rotator cuff tears are prevalent, affecting 20% of the general population, with massive tears accounting for 40% of these cases. Massive tears, those larger than 5 cm or involving several tendons, pose substantial clinical problems, including poorer surgical outcomes and increased recurrence rates. Multiple classification systems offer varied definitions, complicating treatment strategies. The irreparability of these tears, exacerbated by conditions such as tendon atrophy and advanced imaging abnormalities, can further complicate management. Surgical options include superior capsular reconstruction (SCR) and tendon transfers. SCR, which involves attaching a graft to the superior glenoid and greater tuberosity, has shown promise in individuals with intact subscapularis tendons and minimal arthritis. Graft alternatives include fascia lata (FL) autografts, human dermal allografts, and long head of the biceps tendon (LHBT) autografts. Each graft type has distinct advantages and disadvantages, with FL autografts providing greater results despite donor site morbidity. Tendon transfers, such as latissimus dorsi and lower trapezius transfers, offer alternative treatments, especially for younger, more active individuals. This review thoroughly reviews different therapeutic options, emphasizing the most recent evidence and clinical outcomes to help guide the best management of massive posterosuperior irreparable rotator cuff injuries.
- 1 September 2025
- Published by Bioscientifica in EFORT Open Reviews
- Vol. 10 (9) , 660-670
Open AccessExploring superior capsular reconstruction and tendon transfers for massive irreparable posterosuperior rotator cuff tears
Rotator cuff tears are prevalent, affecting 20% of the general population, with massive tears accounting for 40% of these cases. Massive tears, those larger than 5 cm or involving several tendons, pose substantial clinical problems, including poorer surgical outcomes and increased recurrence rates. Multiple classification systems offer varied definitions, complicating treatment strategies. The irreparability of these tears, exacerbated by conditions such as tendon atrophy and advanced imaging abnormalities, can further complicate management. Surgical options include superior capsular reconstruction (SCR) and tendon transfers. SCR, which involves attaching a graft to the superior glenoid and greater tuberosity, has shown promise in individuals with intact subscapularis tendons and minimal arthritis. Graft alternatives include fascia lata (FL) autografts, human dermal allografts, and long head of the biceps tendon (LHBT) autografts. Each graft type has distinct advantages and disadvantages, with FL autografts providing greater results despite donor site morbidity. Tendon transfers, such as latissimus dorsi and lower trapezius transfers, offer alternative treatments, especially for younger, more active individuals. This review thoroughly reviews different therapeutic options, emphasizing the most recent evidence and clinical outcomes to help guide the best management of massive posterosuperior irreparable rotator cuff injuries.
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Finite Element Analysis of Patellofemoral Contact Pressure with Varying Fixation of Transverse Patella Fractures
Background: Understanding patellofemoral contact pressure is crucial for knee biomechanics, as abnormalities can lead to joint issues. This study investigates the changes in contact pressure after surgical fixation of patellar fractures. Methods: Finite element model of the knee was created using cadaveric data on transverse patellar fractures. Models were analyzed and evaluated at 0°, 45°, and 90° flexion under quadriceps force to assess peak pressure, contact pattern, and pressure irregularity. Results: The plate and wire fixation models exhibited distinct stress distribution patterns at 45° and 90° flexion angles. At 45°, the plate model had a higher peak stress (6.14 MPa) in a 21.0-mm ovular contact area, while the wire model had lower peak stress (2.42 MPa) in a smaller, more fragmented region. At 90°, the plate model exhibited concentrated stress (13.26 MPa) in a heart-shaped area, whereas the wire model had 3 dispersed stress points (9.88 MPa) over a broader surface. These findings highlight the plate model's greater stress concentration and the wire model’s more irregular distribution of stress. At 0°, the plate model exhibited minimal contact pressure compared with the wire model, with a pressure of 6.67 MPa. Conclusion: The plate model better preserves patellofemoral biomechanics, potentially reducing complications and improving long-term outcomes. Further research is needed to confirm its superiority as a fixation method. Clinical Relevance: Although the prevalence of patellar fractures remains high, the gold-standard method for surgical fixation has a postoperative complication rate as high as 52.5%. Addressing the lack of understanding surrounding patellofemoral contact pressure in this scenario is an essential step toward improving outcomes for these patients.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Open AccessFinite Element Analysis of Patellofemoral Contact Pressure with Varying Fixation of Transverse Patella Fractures
Background: Understanding patellofemoral contact pressure is crucial for knee biomechanics, as abnormalities can lead to joint issues. This study investigates the changes in contact pressure after surgical fixation of patellar fractures. Methods: Finite element model of the knee was created using cadaveric data on transverse patellar fractures. Models were analyzed and evaluated at 0°, 45°, and 90° flexion under quadriceps force to assess peak pressure, contact pattern, and pressure irregularity. Results: The plate and wire fixation models exhibited distinct stress distribution patterns at 45° and 90° flexion angles. At 45°, the plate model had a higher peak stress (6.14 MPa) in a 21.0-mm ovular contact area, while the wire model had lower peak stress (2.42 MPa) in a smaller, more fragmented region. At 90°, the plate model exhibited concentrated stress (13.26 MPa) in a heart-shaped area, whereas the wire model had 3 dispersed stress points (9.88 MPa) over a broader surface. These findings highlight the plate model's greater stress concentration and the wire model’s more irregular distribution of stress. At 0°, the plate model exhibited minimal contact pressure compared with the wire model, with a pressure of 6.67 MPa. Conclusion: The plate model better preserves patellofemoral biomechanics, potentially reducing complications and improving long-term outcomes. Further research is needed to confirm its superiority as a fixation method. Clinical Relevance: Although the prevalence of patellar fractures remains high, the gold-standard method for surgical fixation has a postoperative complication rate as high as 52.5%. Addressing the lack of understanding surrounding patellofemoral contact pressure in this scenario is an essential step toward improving outcomes for these patients.