ARAli Rteil

Ali Rteil

*This is an algorithmically generated author record based on publicly available information.

Ali Rteil has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Robotic-Assisted Total Hip Arthroplasty Is Associated With Lower Prosthetic Complications in Patients With Lumbar Fusion or Stiff Spine: A Propensity-Matched Cohort Study

    by Ali Rteil, Majd Mzeihem, Marcelline Kemmy, Hristo Piponov, Lalit Puri, Dustin H. Massel, Farid Amirouche

    Background: Patients with spinopelvic risk factors such as lumbar fusion or stiff spine exhibit a 5- to 10-fold increased risk of dislocation following total hip arthroplasty (THA), primarily due to altered spinopelvic mechanics that influence cup positioning. The utilization of robotic-assisted THA facilitates personalized planning, enhancing component placement in this high-risk population. This study aims to compare rates of implant-related and medical complications between robotic-assisted and manual THA in these high-risk patients. Methods: Data were retrospectively obtained from the TriNetX Research Network. Patients with prior lumbar fusion or spinal conditions associated with stiffness or malalignment, and who subsequently underwent THA, were identified using ICD-10 and CPT codes. Procedure codes defined robotic-assisted and manual THA. After 1:1 propensity score matching for age, sex, body mass index, smoking status, and other comorbidities, outcomes were compared at 3, 6, 12 months and 2 years. A subgroup analysis compared both groups in spinal fusion (SF) and nonfusion (no-SF/stiff spine) patients. Results: After 1:1 propensity score matching, each cohort included 2,147 patients. At 3 months, robotic THA was associated with lower prosthetic complications (1.4 vs 2.7%; odds ratio [OR]: 1.86, 95%; P = 0.01) and postoperative blood transfusion (0.9 vs. 1.8%; OR: 2.02, P = 0.01). At 1 year, dislocation was reduced (0.9 vs. 1.8%; OR: 2.07; P = 0.01). Revisions were also lower at 1 and 2-year follow-up in the robotic group (1.7 vs. 2.7%, OR: 1.61; 2.0 vs 3.7%, OR: 1.86; all P < 0.05; respectively), and the manual group had 1.9 times the hazard of having revision surgery at 2 years (HR: 1.9, 95%; P = 0.02). In no-SF patients, robotic THA was associated with markedly lower rates of prosthetic complications and revision surgery. Conclusion: Robotic-assisted THA was associated with fewer complications than manual THA in patients with lumbar fusion or clinically relevant spinal stiffness, a population at elevated risk for instability after THA. Precision-based implant positioning may improve outcomes in patients with altered spinopelvic mobility, including those without spinal fusion.

  • Implant-Related Complications After Robotic-Assisted Versus Manual Revision Knee Arthroplasty: A Propensity-Matched Cohort Study

    by Majd Mzeihem, Ali Rteil, Yasser Farid, Omar Martini, Hristo Piponov, Lalit Puri, Farid Amirouche

    Introduction: As robotic-assisted total knee arthroplasty (TKA) gains traction in revision procedures, the urgent need to investigate its effectiveness compared with manual methods becomes apparent. Methods: Data were retrospectively obtained from the TriNetX Collaborative Network. Revision TKA (rKA) cases were identified using CPT codes and categorized as manual or robotic assisted using ICD-10 procedure codes. Cohorts were balanced with 1:1 propensity score matching for demographics, comorbidities, and revision history. Complication rates were compared across follow-up using chi-square analysis. Results: An initial query identified 19,088 manual and 2,709 robotic-assisted rKA cases. After 1:1 propensity matching, 2,010 patients remained in each group. Robotic rKA had significantly lower mechanical implant‑related complications at 3 and 6 months (OR 1.67 and 1.66; P < 0.001) and lower early VTE, while PJI, readmission, and revision rates were not significantly different. Manual rKA showed higher opioid use at 0 to 3 months (OR 1.40, 95% CI, 1.14 to 1.71, P < 0.001) and 3 to 6 months (OR 1.28, 95% CI, 1.12 to 1.47, P < 0.001) and throughout the 3 years of follow-up.Throughout the follow-up period, patellar dislocation, wound infection, non‑implant-related complications, and transfusion did not differ. At 1 year, manual rKA had higher instability (OR 1.59; P = 0.001) and higher hazard of mechanical implant‑related complications (HR 1.52, 95% CI, 1.32 to 1.75; P = 0.049). Instability, loosening, and periprosthetic fracture remained higher at 2 to 3 years, and revision was significantly more frequent at 3 years (13.5% vs. 11.4%; OR 1.22, 95% CI, 1.02 to 1.46; P = 0.03). Discussion: Robotic-assisted rKA was associated with markedly lower mechanical implant‑related complications across early and midterm follow-up, including reduced rates of instability, aseptic loosening, periprosthetic fracture, VTE, and lower opioid requirements. Rates of PJI, readmission, and revision were largely comparable, although manual rKA demonstrated a markedly higher revision rate by 3 years. These findings suggest that robotic assistance may improve implant reliability and postoperative recovery, but prospective studies and cost-effectiveness analyses remain necessary.