Elisa Jarry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elisa Jarry has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Achim Lenenbach
Fraunhofer Institute for Laser Technology, Aachen, Germany
1 shared publication - Christina Giesen
Fraunhofer Institute for Laser Technology, Aachen, Germany
1 shared publication Gwennaël Danion
University Renneshttps://ror.org/03yn94905, CNRS, Institut FOTON UMR 6082, F-35000 Rennes, France
1 shared publication- Lazar Bochvarov
Fraunhofer ILT, Steinbachstraße 15, Aachen , Germany
1 shared publication - Marc Vallet
University Renneshttps://ror.org/03yn94905, CNRS, Institut FOTON UMR 6082, F-35000 Rennes, France
1 shared publication - Mehdi Alouini
University of Renneshttps://ror.org/015m7wh34, CNRS, Institut FOTON, UMR 6082, F-35000 Rennes, France
1 shared publication
Latest Publications
- 13 August 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (24) , 8229-8234
Analysis of the long-term frequency stability of the Brillouin-assisted self-narrowing photonic oscillator
We unambiguously determine the long-term frequency drift of a Brillouin-assisted self-linewidth-narrowing photonic oscillator, an original architecture that yields high spectral purity without any active stabilization, as we recently reported [ Opt. Express 33 , 1021 –1033 ( 2025 ) OPEXFF 1094-4087 10.1364/OE.534463 ]. A Pound–Drever–Hall locking scheme is used to compare the frequency of the free-running laser to a resonance frequency of a high-finesse Fabry–Perot cavity. The spectral purity of the optical wave, exhibiting a Flicker linewidth of 400 Hz for 0.1 s integration time, is shown to be preserved owing to a locking bandwidth of 5 Hz only. A smooth frequency drift bounded to 1 MHz over 7 h is revealed for the free-running laser. It demonstrates a stability of less than 10 −9 for 1000 s of integration time, outperforming the stabilities reported for free-running lasers.
- 13 August 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (24) , 8229-8234
Analysis of the long-term frequency stability of the Brillouin-assisted self-narrowing photonic oscillator
We unambiguously determine the long-term frequency drift of a Brillouin-assisted self-linewidth-narrowing photonic oscillator, an original architecture that yields high spectral purity without any active stabilization, as we recently reported [ Opt. Express 33 , 1021 –1033 ( 2025 ) OPEXFF 1094-4087 10.1364/OE.534463 ]. A Pound–Drever–Hall locking scheme is used to compare the frequency of the free-running laser to a resonance frequency of a high-finesse Fabry–Perot cavity. The spectral purity of the optical wave, exhibiting a Flicker linewidth of 400 Hz for 0.1 s integration time, is shown to be preserved owing to a locking bandwidth of 5 Hz only. A smooth frequency drift bounded to 1 MHz over 7 h is revealed for the free-running laser. It demonstrates a stability of less than 10 −9 for 1000 s of integration time, outperforming the stabilities reported for free-running lasers.
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 078001-11
Laser coagulation of blood vessels at 454 nm wavelength for neurosurgical interventions
Hemostasis during microsurgery is a critical life-sustaining aspect of surgical procedures and requires precise equipment and reliable processes. Particularly, in neurosurgery, where operations are performed in the vicinity of high-risk structures, such as cranial nerves and neurophysiological monitoring is used for assistance, the precision and low invasiveness of the surgical devices are crucial. Currently, surgeons operate with bipolar forceps that deliver up to 60 W using alternating currents at high frequencies in the radio frequency (RF) range (typically 100 kHz to 5 MHz) for hemostasis. The RF current induces oscillations of intracellular molecules, which result in tissue heating. Above 40°C to 60°C, proteins start to coagulate and form a solid mesh. The tissue starts to dehydrate and vessels begin to shrink at temperatures above 70°C.1 The combination of coagulation and shrinkage leads to vessel occlusion.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 078001-11
Open AccessLaser coagulation of blood vessels at 454 nm wavelength for neurosurgical interventions
Hemostasis during microsurgery is a critical life-sustaining aspect of surgical procedures and requires precise equipment and reliable processes. Particularly, in neurosurgery, where operations are performed in the vicinity of high-risk structures, such as cranial nerves and neurophysiological monitoring is used for assistance, the precision and low invasiveness of the surgical devices are crucial. Currently, surgeons operate with bipolar forceps that deliver up to 60 W using alternating currents at high frequencies in the radio frequency (RF) range (typically 100 kHz to 5 MHz) for hemostasis. The RF current induces oscillations of intracellular molecules, which result in tissue heating. Above 40°C to 60°C, proteins start to coagulate and form a solid mesh. The tissue starts to dehydrate and vessels begin to shrink at temperatures above 70°C.1 The combination of coagulation and shrinkage leads to vessel occlusion.