Lazar Bochvarov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lazar Bochvarov has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Achim Lenenbach
Fraunhofer ILT, Aachen , Germany
2 shared publications- Christina Giesen
Fraunhofer Institute for Laser Technology, Aachen, Germany
2 shared publications - Achim Lenenbach
Fraunhofer Institute for Laser Technology, Aachen, Germany
1 shared publication Christina Giesen
Fraunhofer ILT, Aachen , Germany
1 shared publication- Elisa Jarry
University Renneshttps://ror.org/03yn94905, CNRS, Institut FOTON UMR 6082, F-35000 Rennes, France
1 shared publication Georg Meineke
Fraunhofer ILT, Aachen , Germany
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (2) , 1-4
Compact laser applicator for robot-guided craniotomy in awake neurosurgery
Awake neurosurgical procedures allow surgeons to interact with patients during operations, facilitating real-time functional testing for improved clinical outcome. However, the traditional method of opening the skull using saws and high-speed drills puts severe stress on patients due to the associated noise and vibrations. We present a compact laser scanning applicator that combines laser ablation with OCTbased depth monitoring, designed specifically for use with lightweight collaborative robots. The applicator enables fast, laser ablation of bone tissue over a 5×5 cm² scan field with micron level precision. Key features include beam position tracking, inertial sensing for motion and shock detection, and a miniaturized water spray nozzle for efficient tissue ablation. We demonstrate carbonization-free bone cuts and real-time OCT- based monitoring of ablation depth in ex vivo sheep models. The presented laser-osteotome can enable safer, robot-guided laser surgical workflows in the operating room and increase the acceptance of awake neurosurgery for improved clinical outcome.
- 1 December 2025
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 11 (2) , 1-4
Open AccessCompact laser applicator for robot-guided craniotomy in awake neurosurgery
Awake neurosurgical procedures allow surgeons to interact with patients during operations, facilitating real-time functional testing for improved clinical outcome. However, the traditional method of opening the skull using saws and high-speed drills puts severe stress on patients due to the associated noise and vibrations. We present a compact laser scanning applicator that combines laser ablation with OCTbased depth monitoring, designed specifically for use with lightweight collaborative robots. The applicator enables fast, laser ablation of bone tissue over a 5×5 cm² scan field with micron level precision. Key features include beam position tracking, inertial sensing for motion and shock detection, and a miniaturized water spray nozzle for efficient tissue ablation. We demonstrate carbonization-free bone cuts and real-time OCT- based monitoring of ablation depth in ex vivo sheep models. The presented laser-osteotome can enable safer, robot-guided laser surgical workflows in the operating room and increase the acceptance of awake neurosurgery for improved clinical outcome.
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 078001-11
Laser coagulation of blood vessels at 454 nm wavelength for neurosurgical interventions
Hemostasis during microsurgery is a critical life-sustaining aspect of surgical procedures and requires precise equipment and reliable processes. Particularly, in neurosurgery, where operations are performed in the vicinity of high-risk structures, such as cranial nerves and neurophysiological monitoring is used for assistance, the precision and low invasiveness of the surgical devices are crucial. Currently, surgeons operate with bipolar forceps that deliver up to 60 W using alternating currents at high frequencies in the radio frequency (RF) range (typically 100 kHz to 5 MHz) for hemostasis. The RF current induces oscillations of intracellular molecules, which result in tissue heating. Above 40°C to 60°C, proteins start to coagulate and form a solid mesh. The tissue starts to dehydrate and vessels begin to shrink at temperatures above 70°C.1 The combination of coagulation and shrinkage leads to vessel occlusion.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 078001-11
Open AccessLaser coagulation of blood vessels at 454 nm wavelength for neurosurgical interventions
Hemostasis during microsurgery is a critical life-sustaining aspect of surgical procedures and requires precise equipment and reliable processes. Particularly, in neurosurgery, where operations are performed in the vicinity of high-risk structures, such as cranial nerves and neurophysiological monitoring is used for assistance, the precision and low invasiveness of the surgical devices are crucial. Currently, surgeons operate with bipolar forceps that deliver up to 60 W using alternating currents at high frequencies in the radio frequency (RF) range (typically 100 kHz to 5 MHz) for hemostasis. The RF current induces oscillations of intracellular molecules, which result in tissue heating. Above 40°C to 60°C, proteins start to coagulate and form a solid mesh. The tissue starts to dehydrate and vessels begin to shrink at temperatures above 70°C.1 The combination of coagulation and shrinkage leads to vessel occlusion.
- Open Access
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 646-649
High-Speed Laser Drilling for Dental Implantation: Ablation Process and Applicator Technology
Conventional mechanical drilling for implant placement is limited to specific geometry and orientation, resulting in incorrect positioning and inadequate anchoring in thin or porous bone. This study presents the development of a laser-based ablation process and an applicator technology for precise and fast laser drilling in the oral cavity. For the process development, a CO2 laser with a wavelength of 10.6 μm was used. Pulse durations between 10 μs and 400 μs were investigated for fast laser drilling with low thermal impact. For efficient ablation and cooling of the bone tissue, we applied a fine water spray. The laser applicator is designed with an integrated scanning module, focusing optics and a compact water spray system with three spray nozzles in the applicator tip. The geometry of the cavities was analyzed using digital microscopy and scanning electron microscopy, allowing to measure the ablated volume and depth as well as investigating the bone microstructure. This study demonstrates a laser ablation process capable to generate cavities with an ablation rate of 1.75mm3/s which is about 80% higher than previously reported. At this ablation rate the melted zones were smaller than 30 μm. This paper demonstrates a concept for a dental laser drilling system with a fast ablation process and a highlyintegrated applicator for treatment in the oral cavity.
- 1 September 2023
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 9 (1) , 646-649
Open AccessHigh-Speed Laser Drilling for Dental Implantation: Ablation Process and Applicator Technology
Conventional mechanical drilling for implant placement is limited to specific geometry and orientation, resulting in incorrect positioning and inadequate anchoring in thin or porous bone. This study presents the development of a laser-based ablation process and an applicator technology for precise and fast laser drilling in the oral cavity. For the process development, a CO2 laser with a wavelength of 10.6 μm was used. Pulse durations between 10 μs and 400 μs were investigated for fast laser drilling with low thermal impact. For efficient ablation and cooling of the bone tissue, we applied a fine water spray. The laser applicator is designed with an integrated scanning module, focusing optics and a compact water spray system with three spray nozzles in the applicator tip. The geometry of the cavities was analyzed using digital microscopy and scanning electron microscopy, allowing to measure the ablated volume and depth as well as investigating the bone microstructure. This study demonstrates a laser ablation process capable to generate cavities with an ablation rate of 1.75mm3/s which is about 80% higher than previously reported. At this ablation rate the melted zones were smaller than 30 μm. This paper demonstrates a concept for a dental laser drilling system with a fast ablation process and a highlyintegrated applicator for treatment in the oral cavity.