Lijian Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lijian Yang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ji Chen
University of Houston
4 shared publications Hui Ye
Department of Biology Loyola University Chicago Chicago Illinois USA
3 shared publications- Jianfeng Zheng
Department of Electrical and Computer Engineering University of Houston Houston Texas USA
3 shared publications Ao Shen
Department of Electrical and Computer Engineering University of Houston Houston Texas USA
2 shared publicationsMir Khadiza Akter
Department of Electrical and Computer Engineering University of Houston Houston Texas USA
2 shared publicationsNorbert Kaula
Ncor LLC Arvada Colorado USA
2 shared publications
Latest Publications
- 16 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2863-2872
Unintended Vagus Nerve Stimulation From Cuff Electrode During MRI : Combined Effects of Gradient and Radiofrequency Fields
Purpose: Emissions generated during magnetic resonance imaging (MRI)—including gradient coil induced electric fields and radiofrequency coil induced heating near nerve fiber—may alter neural activation inside patients. This study investigates the combined effects of these emissions on vagus nerve activation in the presence of cuff electrodes. Methods: Electromagnetic, thermal, and neurophysiological simulations were performed to quantify activation thresholds under MRI‐induced fields. The study examined the impact of gradient field exposure and RF‐induced heating, particularly for the trapezoidal waveform of the gradient coil with short pulse duration. Results: The results indicate that the presence of the cuff electrode significantly reduces the activation threshold under gradient field exposure, while RF‐induced heating further decreases the threshold for stimulations with short pulse durations. In some scenarios, the reduced neuron activation threshold can be lower than peripheral nerve stimulation limits defined in IEC 60601‐2‐33. Conclusion: These findings indicate the potential risk of unintended vagus nerve stimulation in MRI environments, emphasizing the need for safety considerations in patients with implantable vagus nerve stimulators.
- 16 January 2026
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (5) , 2863-2872
Unintended Vagus Nerve Stimulation From Cuff Electrode During MRI : Combined Effects of Gradient and Radiofrequency Fields
Purpose: Emissions generated during magnetic resonance imaging (MRI)—including gradient coil induced electric fields and radiofrequency coil induced heating near nerve fiber—may alter neural activation inside patients. This study investigates the combined effects of these emissions on vagus nerve activation in the presence of cuff electrodes. Methods: Electromagnetic, thermal, and neurophysiological simulations were performed to quantify activation thresholds under MRI‐induced fields. The study examined the impact of gradient field exposure and RF‐induced heating, particularly for the trapezoidal waveform of the gradient coil with short pulse duration. Results: The results indicate that the presence of the cuff electrode significantly reduces the activation threshold under gradient field exposure, while RF‐induced heating further decreases the threshold for stimulations with short pulse durations. In some scenarios, the reduced neuron activation threshold can be lower than peripheral nerve stimulation limits defined in IEC 60601‐2‐33. Conclusion: These findings indicate the potential risk of unintended vagus nerve stimulation in MRI environments, emphasizing the need for safety considerations in patients with implantable vagus nerve stimulators.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 172078-172084
Effect of Orthopedic Plate Length on Peripheral Nerve Stimulation During MRI: Combined Gradient-Induced and RF-Thermal Effects
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 172078-172084
Open AccessEffect of Orthopedic Plate Length on Peripheral Nerve Stimulation During MRI: Combined Gradient-Induced and RF-Thermal Effects
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (1) , 21-29
Orthopedic Implants Induced Unintended Nerve Stimulation During Transcutaneous Electrical Nerve Stimulation Treatment
Transcutaneous electrical nerve stimulation (TENS) is a widely used modality for pain relief and neuromuscular rehabilitation. However, the presence of implantable orthopedic devices can significantly distort the surrounding electric field, potentially leading to unintended neuronal activation. This study examines the influence of such implants on nerve stimulation during TENS therapy through a combination of numerical modeling and experimental validation. Electromagnetic simulations and neurophysiological modeling using NEURON, based on an anatomically accurate human body model, demonstrate pronounced electric field distortions at the edges of implantable devices, resulting in a lowered activation threshold for adjacent neurons. These findings are corroborated by phantom experiments, which show substantial alterations in electric field distribution in the presence of orthopedic plates and screws. The results suggest that TENS application should maintain a safe distance from implantable devices to minimize the risk of inadvertent nerve activation.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (1) , 21-29
Orthopedic Implants Induced Unintended Nerve Stimulation During Transcutaneous Electrical Nerve Stimulation Treatment
Transcutaneous electrical nerve stimulation (TENS) is a widely used modality for pain relief and neuromuscular rehabilitation. However, the presence of implantable orthopedic devices can significantly distort the surrounding electric field, potentially leading to unintended neuronal activation. This study examines the influence of such implants on nerve stimulation during TENS therapy through a combination of numerical modeling and experimental validation. Electromagnetic simulations and neurophysiological modeling using NEURON, based on an anatomically accurate human body model, demonstrate pronounced electric field distortions at the edges of implantable devices, resulting in a lowered activation threshold for adjacent neurons. These findings are corroborated by phantom experiments, which show substantial alterations in electric field distribution in the presence of orthopedic plates and screws. The results suggest that TENS application should maintain a safe distance from implantable devices to minimize the risk of inadvertent nerve activation.
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. PP (00189375) , 1-10
Assessing RF-Induced Heating of Active Implantable Medical Devices Near Orthopedic Implants During 1.5 T MRI
Existing methods for evaluating radiofrequency (RF)-induced heating typically assess active implantable medical devices (AIMDs) in isolation, without accounting for interactions with surrounding passive implants. This oversight can lead to under- or overestimation of heating in clinical scenarios involving multiple implants. This article presents an efficient approach for assessing RF-induced heating of AIMDs in a magnetic resonance imaging (MRI) environment when other implantable medical devices are present. The method leverages the transfer function approach to evaluate heating effects. To demonstrate its effectiveness, in vitro simulations and experiments were conducted using a cervical plate at various configurations. RF-induced heating within a human body model was then analyzed for an AIMD with and without nearby implantable devices. The results show that RF-induced heating at the lead tip varied by up to 36.7%, depending on the type and location of nearby passive implants. These findings highlight the critical need to incorporate multi-implant interactions into RF safety assessments to achieve more accurate and clinically relevant predictions.
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. PP (00189375) , 1-10
Assessing RF-Induced Heating of Active Implantable Medical Devices Near Orthopedic Implants During 1.5 T MRI
Existing methods for evaluating radiofrequency (RF)-induced heating typically assess active implantable medical devices (AIMDs) in isolation, without accounting for interactions with surrounding passive implants. This oversight can lead to under- or overestimation of heating in clinical scenarios involving multiple implants. This article presents an efficient approach for assessing RF-induced heating of AIMDs in a magnetic resonance imaging (MRI) environment when other implantable medical devices are present. The method leverages the transfer function approach to evaluate heating effects. To demonstrate its effectiveness, in vitro simulations and experiments were conducted using a cervical plate at various configurations. RF-induced heating within a human body model was then analyzed for an AIMD with and without nearby implantable devices. The results show that RF-induced heating at the lead tip varied by up to 36.7%, depending on the type and location of nearby passive implants. These findings highlight the critical need to incorporate multi-implant interactions into RF safety assessments to achieve more accurate and clinically relevant predictions.