Orthopedic Implants Induced Unintended Nerve Stimulation During Transcutaneous Electrical Nerve Stimulation Treatment
- 11 November 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 68 (1) , 21-29
Abstract
Transcutaneous electrical nerve stimulation (TENS) is a widely used modality for pain relief and neuromuscular rehabilitation. However, the presence of implantable orthopedic devices can significantly distort the surrounding electric field, potentially leading to unintended neuronal activation. This study examines the influence of such implants on nerve stimulation during TENS therapy through a combination of numerical modeling and experimental validation. Electromagnetic simulations and neurophysiological modeling using NEURON, based on an anatomically accurate human body model, demonstrate pronounced electric field distortions at the edges of implantable devices, resulting in a lowered activation threshold for adjacent neurons. These findings are corroborated by phantom experiments, which show substantial alterations in electric field distribution in the presence of orthopedic plates and screws. The results suggest that TENS application should maintain a safe distance from implantable devices to minimize the risk of inadvertent nerve activation.Keywords
This publication has 27 references indexed in Scilit:
- Computational study of the effects of orthopedic plates on gradient‐induced peripheral nerve stimulation under MRI using electromagnetic and neurophysiological modelingMagnetic Resonance in Medicine, 2025
- Safety of non-invasive brain stimulation in patients with implants: a computational risk assessmentJournal of Neural Engineering, 2025
- Modeling implanted metals in electrical stimulation applicationsJournal of Neural Engineering, 2022
- Effects of Transcutaneous Electric Nerve Stimulation on Upper Extremity Proprioceptive Function2020
- Materials evolution of bone plates for internal fixation of bone fractures: A reviewJournal of Materials Science & Technology, 2020
- Systematic Review of Three Electrical Stimulation Techniques for Rehabilitation After Total Knee ArthroplastyThe Journal of Arthroplasty, 2018
- Cervical vagus nerve morphometry and vascularity in the context of nerve stimulation - A cadaveric studyScientific Reports, 2018
- Computation of Induced Current Densities in the Human Body at Low Frequencies Due to Contact Electrodes Using the ADI-FDTD MethodIEEE Transactions on Electromagnetic Compatibility, 2010
- Transcutaneous electrical nerve stimulation: Basic science mechanisms and clinical effectivenessThe Journal of Pain, 2003
- Analysis of models for extracellular fiber stimulationIEEE Transactions on Biomedical Engineering, 1989