Latest Publications
- Open Access
- 28 July 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (4) , e70155
A Novel Technique for Diaphragmatic Compound Motor Action Potential Monitoring Using the BeeAT Catheter During Cryoballoon Ablation for Atrial Fibrillation
Background: Diaphragmatic compound motor action potential (CMAP) monitoring helps prevent phrenic nerve palsy during cryoballoon ablation (CBA) for atrial fibrillation. Methods: This retrospective analysis included 95 patients who had undergone CBA. Phrenic nerve pacing was performed via the distal electrode of a BeeAT catheter positioned in the right subclavian vein, with CMAPs recorded from the most proximal electrode in the subdiaphragmatic inferior vena cava. Results: CMAP amplitude was unaffected by patient body habitus (mean: 1.14 ± 0.58 mV; CMAP‐to‐ventricular wave ratio: 8.76). Conclusions: This technique provides stable, well‐defined signals with minimal artifacts, enhancing the reliability of CMAP monitoring during CBA.
- 28 July 2025
- Published by Wiley in Journal of Arrhythmia
- Vol. 41 (4) , e70155
Open AccessA Novel Technique for Diaphragmatic Compound Motor Action Potential Monitoring Using the BeeAT Catheter During Cryoballoon Ablation for Atrial Fibrillation
Background: Diaphragmatic compound motor action potential (CMAP) monitoring helps prevent phrenic nerve palsy during cryoballoon ablation (CBA) for atrial fibrillation. Methods: This retrospective analysis included 95 patients who had undergone CBA. Phrenic nerve pacing was performed via the distal electrode of a BeeAT catheter positioned in the right subclavian vein, with CMAPs recorded from the most proximal electrode in the subdiaphragmatic inferior vena cava. Results: CMAP amplitude was unaffected by patient body habitus (mean: 1.14 ± 0.58 mV; CMAP‐to‐ventricular wave ratio: 8.76). Conclusions: This technique provides stable, well‐defined signals with minimal artifacts, enhancing the reliability of CMAP monitoring during CBA.