Zihao Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zihao Yuan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Guangyi Zhao
Southwestern Institute of Physics 2 , Chengdu 610041
3 shared publications- Chenyu Xiao
Sino-French Institute of Nuclear Engineering and Technology, Sun Yat-Sen University 1 , Zhuhai 519082
2 shared publications Hao Liu
2 shared publications- Hao Xu
Sino-French Institute of Nuclear Engineering and Technology, Sun Yat-Sen University 1 , Zhuhai 519082
2 shared publications - Lin Nie
Southwestern Institute of Physics 2 , Chengdu 610041
2 shared publications Min Xu
2 shared publications
Latest Publications
- Open Access
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Development of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks
In this work, we present the first Lyman-Alpha-Based Beam Emission Spectroscopy (LAB) diagnostic system. This system achieves a significantly enhanced radial spatial resolution of ∼3.3 mm compared to conventional BES. The LAB diagnostic monitors the vacuum ultraviolet Lyman-alpha line (n = 2 → 1 transition, 121.53 nm) and has been implemented on the HL-2A tokamak with twenty spatial channels covering the edge plasma region (ρ = 0.73–1.01) for standard HL-2A discharges. Beyond spatial resolution improvements, the LAB system shows over tenfold signal amplification relative to traditional BES. The entire optical assembly has been securely assembled and underwent rigorous testing within a dedicated vacuum chamber interfaced with HL-2A’s main vacuum system. The monochromator provides linear dispersion of ∼0.09nm/mm and successfully resolves adjacent hydrogen isotope emission lines (HI: 121.567 nm and DI: 121.534 nm) using a 100 μm slit. With a temporal resolution of 1 μs, the LAB diagnostic is a powerful tool for investigating localized, small-scale, high-frequency plasma phenomena in tokamaks.
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Open AccessDevelopment of a vacuum ultraviolet diagnostic system with millimeter resolution for density fluctuation measurements in tokamaks
In this work, we present the first Lyman-Alpha-Based Beam Emission Spectroscopy (LAB) diagnostic system. This system achieves a significantly enhanced radial spatial resolution of ∼3.3 mm compared to conventional BES. The LAB diagnostic monitors the vacuum ultraviolet Lyman-alpha line (n = 2 → 1 transition, 121.53 nm) and has been implemented on the HL-2A tokamak with twenty spatial channels covering the edge plasma region (ρ = 0.73–1.01) for standard HL-2A discharges. Beyond spatial resolution improvements, the LAB system shows over tenfold signal amplification relative to traditional BES. The entire optical assembly has been securely assembled and underwent rigorous testing within a dedicated vacuum chamber interfaced with HL-2A’s main vacuum system. The monochromator provides linear dispersion of ∼0.09nm/mm and successfully resolves adjacent hydrogen isotope emission lines (HI: 121.567 nm and DI: 121.534 nm) using a 100 μm slit. With a temporal resolution of 1 μs, the LAB diagnostic is a powerful tool for investigating localized, small-scale, high-frequency plasma phenomena in tokamaks.
- 1 August 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 220
Calibration of a novel near-infrared phase contrast imaging on the HL-3 Tokamak
- 1 August 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 220
Calibration of a novel near-infrared phase contrast imaging on the HL-3 Tokamak
- 17 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1893-1897
A Method of Vehicle Peripheral Objects Detection Based on Binocular Vision
Aiming at the collision problem that may occur when the passenger opens the door after the vehicle stops, this paper proposes an obj ect detection algorithm around the vehicle based on binocular vision. Due to the high computational complexity of binocular registration, the stereo correction of the image is realized by combining the dual-target fixed parameters and Bouguet Reprojection Algorithm, so that the binocular image is corrected into coplanar line alignment, and the operational efficiency is improved. The You Only Look Once algorithm is used to realize the recognition of people and vehicles on the road. In order to reduce the probability of missing detection and wrong detection of the algorithm in the remote scene, the up-sampling fusion method of the feature pyramid is adopted to detect the target on three feature layers, so as to realize the real-time detection and tracking of the target. Then, Scale-invariant Feature Transform Algorithm is used to obtain the matching points in the target area, and the distance between the feature points in the image and the camera is measured through coordinate transformation. At last, the system is tested at National Supervision &Inspection Centre for Inside Vehicle. The accuracy of the proposed algorithm for measuring the distance of various types of targets is above 96%.
- 17 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1893-1897
A Method of Vehicle Peripheral Objects Detection Based on Binocular Vision
Aiming at the collision problem that may occur when the passenger opens the door after the vehicle stops, this paper proposes an obj ect detection algorithm around the vehicle based on binocular vision. Due to the high computational complexity of binocular registration, the stereo correction of the image is realized by combining the dual-target fixed parameters and Bouguet Reprojection Algorithm, so that the binocular image is corrected into coplanar line alignment, and the operational efficiency is improved. The You Only Look Once algorithm is used to realize the recognition of people and vehicles on the road. In order to reduce the probability of missing detection and wrong detection of the algorithm in the remote scene, the up-sampling fusion method of the feature pyramid is adopted to detect the target on three feature layers, so as to realize the real-time detection and tracking of the target. Then, Scale-invariant Feature Transform Algorithm is used to obtain the matching points in the target area, and the distance between the feature points in the image and the camera is measured through coordinate transformation. At last, the system is tested at National Supervision &Inspection Centre for Inside Vehicle. The accuracy of the proposed algorithm for measuring the distance of various types of targets is above 96%.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Microstructure and Mechanical Properties of Selective Laser Melted Reduced Activation Ferritic/Martensitic Steel
The cube and tensile samples of reduced activation ferritic/martensitic steel were formed at different laser powers and scanning velocities using selective laser melting process, and the microstructural characteristics and tensile properties of the cube and tensile samples were analyzed in this study. The experimental results shown that the SLMed CLF-1 samples formed with selected laser melting have near-fully dense, and the relative density of SLMed CLF-1 samples exceeds 99%. Meanwhile, numerous nano-sized spherical and needle-like precipitates dispersion distributed in the grains and the boundary of the grains, and the precipitates are mainly composed of M 23 C 6 carbide and MX carbide. The microstructure is that columnar grains and equiaxed grains arranged in sequence, and the smallest average size of grains is 15 µm at the 320 W power with 800 mm/s scanning velocity. In addition, the sample at 320 W power with 800 mm/s scanning velocity exhibits higher yield strength (875 Mpa) and higher elongation (25.6%) than that of the sample at 200 W power with 800 mm/s scanning velocity with yield strength (715 Mpa) and elongation (22.6%).
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessMicrostructure and Mechanical Properties of Selective Laser Melted Reduced Activation Ferritic/Martensitic Steel
The cube and tensile samples of reduced activation ferritic/martensitic steel were formed at different laser powers and scanning velocities using selective laser melting process, and the microstructural characteristics and tensile properties of the cube and tensile samples were analyzed in this study. The experimental results shown that the SLMed CLF-1 samples formed with selected laser melting have near-fully dense, and the relative density of SLMed CLF-1 samples exceeds 99%. Meanwhile, numerous nano-sized spherical and needle-like precipitates dispersion distributed in the grains and the boundary of the grains, and the precipitates are mainly composed of M 23 C 6 carbide and MX carbide. The microstructure is that columnar grains and equiaxed grains arranged in sequence, and the smallest average size of grains is 15 µm at the 320 W power with 800 mm/s scanning velocity. In addition, the sample at 320 W power with 800 mm/s scanning velocity exhibits higher yield strength (875 Mpa) and higher elongation (25.6%) than that of the sample at 200 W power with 800 mm/s scanning velocity with yield strength (715 Mpa) and elongation (22.6%).