Qinfang Miao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qinfang Miao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Haikun Qi
3 shared publicationsHongzhang Huang
3 shared publicationsPeng Hu
3 shared publications- Haikun Qi
ShanghaiTech University
2 shared publications - Hongzhang Huang
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, 393 Middle Huaxia Road, Pudong District, Shanghai 201210, China
2 shared publications Tianyi Wu
2 shared publications
Latest Publications
- Open Access
- 17 August 2026
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
Myocardial T1 and T2 Mapping at 5.0T: Feasibility and Comparison with 3.0-T MRI
- 17 August 2026
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
Open AccessMyocardial T1 and T2 Mapping at 5.0T: Feasibility and Comparison with 3.0-T MRI
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250488
Cardiac MRI Monitoring of Myocardial Tissue Changes in a Myocarditis Mouse Model with Histologic Validation
Multiparametric cardiac MRI depicted dynamic, region-specific progression from inflammation to fibrosis in autoimmune myocarditis, with T2 mapping and extracellular volume fraction supporting stage-specific tissue characterization.
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250488
Cardiac MRI Monitoring of Myocardial Tissue Changes in a Myocarditis Mouse Model with Histologic Validation
Multiparametric cardiac MRI depicted dynamic, region-specific progression from inflammation to fibrosis in autoimmune myocarditis, with T2 mapping and extracellular volume fraction supporting stage-specific tissue characterization.
- 19 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 136-150
Detection of Coronary Microvascular Dysfunction in Diabetic Mice Using Arterial Spin Labeling Cardiac MRI : A Multimodality Imaging Comparison
Background: Coronary microvascular dysfunction (CMD) is a major contributor to cardiovascular complications in diabetes. Although noninvasive techniques such as arterial spin labeling cardiac MRI (ASL‐MRI) and transthoracic echocardiography (TTE) are available, their comparative performance for CMD remains unclear. Purpose: To compare ASL‐MRI and TTE for CMD assessment in type 1 and type 2 (T1DM, T2DM) mouse models and relate functional indices to histological microvascular and myocardial remodeling, including early‐stage T2DM (8w‐T2DM). Study Type: Prospective. Animal Model: Forty 8‐week‐old male C57BL/6J mice allocated to five groups: control, T1DM, and T2DM ( n = 10 per group, imaged 16 weeks postinduction), and early‐stage T2DM (8w‐T2DM) and age‐matched controls ( n = 5 per group, imaged 8 weeks post‐induction). Field Strength/Sequence: Segmented FLASH cine, steady‐pulsed labeling ASL, and inversion‐recovery segmented FLASH (T1 mapping) sequences at 9.4 T. Assessment: Rest/stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) were derived from ASL data using a model‐based approach incorporating native T1 (from segmented FLASH data). Coronary flow velocity (CFV) and reserve (CFVR) were measured by TTE at rest (1.5% isoflurane) and stress (2.5% isoflurane). Histology included assessment of hematoxylin–eosin (myocyte area), Masson (collagen), and IB4 (capillary density). Statistical Tests: Group comparisons used t ‐tests, Mann–Whitney U tests, and one‐/two‐way ANOVA with Bonferroni correction; correlations were assessed with Pearson or Spearman coefficients ( r ). p < 0.05 was considered significant. Results: 38 animals completed MR and TTE imaging. At 16 weeks, stress diastolic MBF was significantly lower in T1DM (14.67 ± 1.62 mL/g/min) and T2DM (13.42 ± 2.44 mL/g/min) vs. controls (22.19 ± 0.25 mL/g/min), with significantly reduced MPR in T2DM (1.53 ± 0.17 vs. 2.27 ± 0.15). TTE showed significantly reduced CFVR only in T2DM (2.16 ± 0.24 vs. 2.75 ± 0.24). In 8w‐T2DM, ASL‐MRI detected significantly reduced MPR (1.87 ± 0.16 vs. 2.26 ± 0.13), whereas TTE showed no significant CFVR change ( p = 0.900). Capillary density significantly decreased in 16‐week and 8‐week T2DM. IB4‐positive area correlated with CFVR ( r = 0.673) and more strongly with MPR ( r = 0.810). Conclusion: ASL‐MRI detected CMD in diabetic mice, outperforming TTE in early‐stage disease and showing a strong association with microvascular injury. Evidence Level: 1. Technical Efficacy: Stage 2.
- 19 March 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (1) , 136-150
Detection of Coronary Microvascular Dysfunction in Diabetic Mice Using Arterial Spin Labeling Cardiac MRI : A Multimodality Imaging Comparison
Background: Coronary microvascular dysfunction (CMD) is a major contributor to cardiovascular complications in diabetes. Although noninvasive techniques such as arterial spin labeling cardiac MRI (ASL‐MRI) and transthoracic echocardiography (TTE) are available, their comparative performance for CMD remains unclear. Purpose: To compare ASL‐MRI and TTE for CMD assessment in type 1 and type 2 (T1DM, T2DM) mouse models and relate functional indices to histological microvascular and myocardial remodeling, including early‐stage T2DM (8w‐T2DM). Study Type: Prospective. Animal Model: Forty 8‐week‐old male C57BL/6J mice allocated to five groups: control, T1DM, and T2DM ( n = 10 per group, imaged 16 weeks postinduction), and early‐stage T2DM (8w‐T2DM) and age‐matched controls ( n = 5 per group, imaged 8 weeks post‐induction). Field Strength/Sequence: Segmented FLASH cine, steady‐pulsed labeling ASL, and inversion‐recovery segmented FLASH (T1 mapping) sequences at 9.4 T. Assessment: Rest/stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) were derived from ASL data using a model‐based approach incorporating native T1 (from segmented FLASH data). Coronary flow velocity (CFV) and reserve (CFVR) were measured by TTE at rest (1.5% isoflurane) and stress (2.5% isoflurane). Histology included assessment of hematoxylin–eosin (myocyte area), Masson (collagen), and IB4 (capillary density). Statistical Tests: Group comparisons used t ‐tests, Mann–Whitney U tests, and one‐/two‐way ANOVA with Bonferroni correction; correlations were assessed with Pearson or Spearman coefficients ( r ). p < 0.05 was considered significant. Results: 38 animals completed MR and TTE imaging. At 16 weeks, stress diastolic MBF was significantly lower in T1DM (14.67 ± 1.62 mL/g/min) and T2DM (13.42 ± 2.44 mL/g/min) vs. controls (22.19 ± 0.25 mL/g/min), with significantly reduced MPR in T2DM (1.53 ± 0.17 vs. 2.27 ± 0.15). TTE showed significantly reduced CFVR only in T2DM (2.16 ± 0.24 vs. 2.75 ± 0.24). In 8w‐T2DM, ASL‐MRI detected significantly reduced MPR (1.87 ± 0.16 vs. 2.26 ± 0.13), whereas TTE showed no significant CFVR change ( p = 0.900). Capillary density significantly decreased in 16‐week and 8‐week T2DM. IB4‐positive area correlated with CFVR ( r = 0.673) and more strongly with MPR ( r = 0.810). Conclusion: ASL‐MRI detected CMD in diabetic mice, outperforming TTE in early‐stage disease and showing a strong association with microvascular injury. Evidence Level: 1. Technical Efficacy: Stage 2.
- 4 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 756-769
Rapid free‐breathing myocardial T 1 mapping with free‐running interleaved multi‐slice acquisition and respiratory motion correction using self‐navigated auto calibration
Purpose: To develop a rapid 2D free‐running myocardial mapping technique that is robust to through‐plane respiratory motion. Methods: A free‐running golden angle radial sequence consisting of encoding and self‐navigated auto motion calibration (SNAC) was developed. The encoding adopted inversion recovery (IR) prepared interleaved multi‐slice acquisition with optimized inter‐slice gap to ensure a uniform excitation of the middle slice regardless of through‐plane respiratory motion. The flip angles were alternated between the odd and even IR readouts to correct flip‐angle errors. SNAC was designed to calibrate the through‐plane motion with the respiratory self‐navigation signal extracted from the free‐running sequence, and integrate the multi‐slice data into a through‐plane motion‐corrected 2D slice for mapping reconstruction. Numerical simulations were performed to optimize the key sequence parameters, followed by phantom and in‐vivo imaging to validate the accuracy and repeatability. Results: Numerical simulations yielded the dual flip angles minimizing estimation errors and the adjacent slice offset achieving uniformity in the superimposed slice profile. Phantom experiments demonstrated a strong correlation between the proposed and reference method, and no dependence of the free‐running estimation on heart rates. Adding through‐plane respiratory motion correction significantly improved the in‐vivo mapping sharpness and visual quality. Validated against the conventional breath‐hold mapping technique, the motion corrected free‐running method achieved comparable mapping quality and repeatability. Conclusion: Respiratory motion is effectively suppressed in the proposed 2D free‐running method, which achieves superior mapping with acceptable repeatability in a short scan time of 46 s.
- 4 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 756-769
Rapid free‐breathing myocardial T 1 mapping with free‐running interleaved multi‐slice acquisition and respiratory motion correction using self‐navigated auto calibration
Purpose: To develop a rapid 2D free‐running myocardial mapping technique that is robust to through‐plane respiratory motion. Methods: A free‐running golden angle radial sequence consisting of encoding and self‐navigated auto motion calibration (SNAC) was developed. The encoding adopted inversion recovery (IR) prepared interleaved multi‐slice acquisition with optimized inter‐slice gap to ensure a uniform excitation of the middle slice regardless of through‐plane respiratory motion. The flip angles were alternated between the odd and even IR readouts to correct flip‐angle errors. SNAC was designed to calibrate the through‐plane motion with the respiratory self‐navigation signal extracted from the free‐running sequence, and integrate the multi‐slice data into a through‐plane motion‐corrected 2D slice for mapping reconstruction. Numerical simulations were performed to optimize the key sequence parameters, followed by phantom and in‐vivo imaging to validate the accuracy and repeatability. Results: Numerical simulations yielded the dual flip angles minimizing estimation errors and the adjacent slice offset achieving uniformity in the superimposed slice profile. Phantom experiments demonstrated a strong correlation between the proposed and reference method, and no dependence of the free‐running estimation on heart rates. Adding through‐plane respiratory motion correction significantly improved the in‐vivo mapping sharpness and visual quality. Validated against the conventional breath‐hold mapping technique, the motion corrected free‐running method achieved comparable mapping quality and repeatability. Conclusion: Respiratory motion is effectively suppressed in the proposed 2D free‐running method, which achieves superior mapping with acceptable repeatability in a short scan time of 46 s.
- Open Access
Myocardial T1 and T2 Mapping at 5.0 T: Feasibility and Comparison with 3.0-T MRI
Background: Myocardial T1 and T2 mapping provide a non-invasive quantitative assessment of cardiac tissue. While established at 1.5-T and 3.0-T MRI, the mapping performance and reference values at 5.0-T MRI remain to be investigated. This study aims to evaluate the feasibility and establish reference values for cardiac T1 and T2 mapping at 5.0-T MRI in healthy subjects. Methods: In this prospective study, 50 healthy volunteers underwent cardiac MRI at both 3.0-T and 5.0-T MRI systems from February to April 2025. Mapping protocols included MOdified Look Locker Inversion recovery (MOLLI, T1), T2-prepared gradient-echo (T2-prep-GRE, T2), and a simultaneous multi-parametric mapping technique (Multimap, T1 and T2). At 3.0-T MRI, both balanced steady-state free precession (bSSFP) and fast low-angle shot (FLASH) readouts were employed, while only the FLASH readout was used at 5.0-T MRI. Intra-observer, inter-observer, and scan-rescan reproducibility were assessed. Statistical analyses included coefficient of variation (CoV), intraclass correlation coefficient (ICC), and Bland-Altman analysis. Results: All techniques at 5.0-T MRI yielded high-quality, artifact-free images. Native T1 values were significantly higher at 5.0 T than at 3.0-T MRI (MOLLI: 1452.9 ± 33.2 ms vs. 1305.9 ± 38.3 ms, P < 0.0001), while T2 values were significantly lower (T2-prep-GRE: 37.53 ± 1.74 ms vs. 43.97 ± 2.95 ms, P < 0.0001). Scan-rescan reproducibility at 5.0 T (ICC: 0.87–0.92; CoV: 2.41%–3.25%) was comparable to 3.0-T MRI. The measurement precision of 5.0 T was higher than 3.0-T MRI with FLASH readout and slightly inferior to bSSFP-based techniques. Multimap achieved efficient, simultaneous T1 and T2 quantification with acceptable reproducibility at 5.0-T MRI. Conclusion: Myocardial T1 and T2 mapping at 5.0-T MRI are reliable and reproducible in healthy individuals, offering reference values for normal myocardium at this field strength. The good measurement reproducibility and precision of 5.0-T cardiac mapping support its clinical potential for myocardial tissue characterization.
Open AccessMyocardial T1 and T2 Mapping at 5.0 T: Feasibility and Comparison with 3.0-T MRI
Background: Myocardial T1 and T2 mapping provide a non-invasive quantitative assessment of cardiac tissue. While established at 1.5-T and 3.0-T MRI, the mapping performance and reference values at 5.0-T MRI remain to be investigated. This study aims to evaluate the feasibility and establish reference values for cardiac T1 and T2 mapping at 5.0-T MRI in healthy subjects. Methods: In this prospective study, 50 healthy volunteers underwent cardiac MRI at both 3.0-T and 5.0-T MRI systems from February to April 2025. Mapping protocols included MOdified Look Locker Inversion recovery (MOLLI, T1), T2-prepared gradient-echo (T2-prep-GRE, T2), and a simultaneous multi-parametric mapping technique (Multimap, T1 and T2). At 3.0-T MRI, both balanced steady-state free precession (bSSFP) and fast low-angle shot (FLASH) readouts were employed, while only the FLASH readout was used at 5.0-T MRI. Intra-observer, inter-observer, and scan-rescan reproducibility were assessed. Statistical analyses included coefficient of variation (CoV), intraclass correlation coefficient (ICC), and Bland-Altman analysis. Results: All techniques at 5.0-T MRI yielded high-quality, artifact-free images. Native T1 values were significantly higher at 5.0 T than at 3.0-T MRI (MOLLI: 1452.9 ± 33.2 ms vs. 1305.9 ± 38.3 ms, P < 0.0001), while T2 values were significantly lower (T2-prep-GRE: 37.53 ± 1.74 ms vs. 43.97 ± 2.95 ms, P < 0.0001). Scan-rescan reproducibility at 5.0 T (ICC: 0.87–0.92; CoV: 2.41%–3.25%) was comparable to 3.0-T MRI. The measurement precision of 5.0 T was higher than 3.0-T MRI with FLASH readout and slightly inferior to bSSFP-based techniques. Multimap achieved efficient, simultaneous T1 and T2 quantification with acceptable reproducibility at 5.0-T MRI. Conclusion: Myocardial T1 and T2 mapping at 5.0-T MRI are reliable and reproducible in healthy individuals, offering reference values for normal myocardium at this field strength. The good measurement reproducibility and precision of 5.0-T cardiac mapping support its clinical potential for myocardial tissue characterization.