Hongzhang Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongzhang Huang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Qinfang Miao
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices ShanghaiTech University Shanghai China
2 shared publications - Zhenfeng Lyu
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, 393 Middle Huaxia Road, Pudong District, Shanghai 201210, China
2 shared publications Chuangwei Wei
Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
1 shared publicationGenqiang Chen
Shanghai Institute of Ceramics Chinese Academy of Sciences Shanghai China
1 shared publicationHaikun Qi
School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, 393 Middle Huaxia Road, Pudong District, Shanghai 201210, China
1 shared publication- Haikun Qi
ShanghaiTech University
1 shared publication
Latest Publications
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250488
Cardiac MRI Monitoring of Myocardial Tissue Changes in a Myocarditis Mouse Model with Histologic Validation
Multiparametric cardiac MRI depicted dynamic, region-specific progression from inflammation to fibrosis in autoimmune myocarditis, with T2 mapping and extracellular volume fraction supporting stage-specific tissue characterization.
- 1 June 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (3) , e250488
Cardiac MRI Monitoring of Myocardial Tissue Changes in a Myocarditis Mouse Model with Histologic Validation
Multiparametric cardiac MRI depicted dynamic, region-specific progression from inflammation to fibrosis in autoimmune myocarditis, with T2 mapping and extracellular volume fraction supporting stage-specific tissue characterization.
- 4 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 756-769
Rapid free‐breathing myocardial T 1 mapping with free‐running interleaved multi‐slice acquisition and respiratory motion correction using self‐navigated auto calibration
Purpose: To develop a rapid 2D free‐running myocardial mapping technique that is robust to through‐plane respiratory motion. Methods: A free‐running golden angle radial sequence consisting of encoding and self‐navigated auto motion calibration (SNAC) was developed. The encoding adopted inversion recovery (IR) prepared interleaved multi‐slice acquisition with optimized inter‐slice gap to ensure a uniform excitation of the middle slice regardless of through‐plane respiratory motion. The flip angles were alternated between the odd and even IR readouts to correct flip‐angle errors. SNAC was designed to calibrate the through‐plane motion with the respiratory self‐navigation signal extracted from the free‐running sequence, and integrate the multi‐slice data into a through‐plane motion‐corrected 2D slice for mapping reconstruction. Numerical simulations were performed to optimize the key sequence parameters, followed by phantom and in‐vivo imaging to validate the accuracy and repeatability. Results: Numerical simulations yielded the dual flip angles minimizing estimation errors and the adjacent slice offset achieving uniformity in the superimposed slice profile. Phantom experiments demonstrated a strong correlation between the proposed and reference method, and no dependence of the free‐running estimation on heart rates. Adding through‐plane respiratory motion correction significantly improved the in‐vivo mapping sharpness and visual quality. Validated against the conventional breath‐hold mapping technique, the motion corrected free‐running method achieved comparable mapping quality and repeatability. Conclusion: Respiratory motion is effectively suppressed in the proposed 2D free‐running method, which achieves superior mapping with acceptable repeatability in a short scan time of 46 s.
- 4 September 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (2) , 756-769
Rapid free‐breathing myocardial T 1 mapping with free‐running interleaved multi‐slice acquisition and respiratory motion correction using self‐navigated auto calibration
Purpose: To develop a rapid 2D free‐running myocardial mapping technique that is robust to through‐plane respiratory motion. Methods: A free‐running golden angle radial sequence consisting of encoding and self‐navigated auto motion calibration (SNAC) was developed. The encoding adopted inversion recovery (IR) prepared interleaved multi‐slice acquisition with optimized inter‐slice gap to ensure a uniform excitation of the middle slice regardless of through‐plane respiratory motion. The flip angles were alternated between the odd and even IR readouts to correct flip‐angle errors. SNAC was designed to calibrate the through‐plane motion with the respiratory self‐navigation signal extracted from the free‐running sequence, and integrate the multi‐slice data into a through‐plane motion‐corrected 2D slice for mapping reconstruction. Numerical simulations were performed to optimize the key sequence parameters, followed by phantom and in‐vivo imaging to validate the accuracy and repeatability. Results: Numerical simulations yielded the dual flip angles minimizing estimation errors and the adjacent slice offset achieving uniformity in the superimposed slice profile. Phantom experiments demonstrated a strong correlation between the proposed and reference method, and no dependence of the free‐running estimation on heart rates. Adding through‐plane respiratory motion correction significantly improved the in‐vivo mapping sharpness and visual quality. Validated against the conventional breath‐hold mapping technique, the motion corrected free‐running method achieved comparable mapping quality and repeatability. Conclusion: Respiratory motion is effectively suppressed in the proposed 2D free‐running method, which achieves superior mapping with acceptable repeatability in a short scan time of 46 s.