Jennifer Michelle López-Jiménez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jennifer Michelle López-Jiménez has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jaime Lora-García
Research Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de València, Vera Campus Camí de Vera, s/n, 46022 València, Spain
2 shared publications - Paola Andrea Alvizuri-Tintaya
Centro de Investigación en Agua, Energía y Sostenibilidad (CINAES), Universidad Católica Boliviana “San Pablo”, 4807 14 de Septiembre Avenue, La Paz, Bolivia
2 shared publications - Alicia Iborra-Clar
Research Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de València, Vera Campus Camí de Vera, s/n, 46022 València, Spain
1 shared publication - Georgina Chávez
Centro de Investigación en Agua, Energía y Sostenibilidad (CINAES) Universidad Católica Boliviana “San Pablo
1 shared publication - Jose Luis Soler-Cabezas
Research Institute for Industrial, Radiophysical and Environmental Safety (ISIRYM), Universitat Politècnica de València, Vera Campus Camí de Vera, s/n, 46022 València, Spain
1 shared publication - Juan Ignacio Torregrosa-López
Project Management, Innovation and Sustainability Research Center (PRINS), Alcoy Campus, Universitat Politècnica de València, Plaza Ferrándiz y Carbonell, s/n, E-03801 Alcoy, Spain
1 shared publication
Latest Publications
- Open Access
Accessible Fabrication and Functional Characterization of Polyethersulfone Ultrafiltration Membranes: Effects of NIPS Processing Conditions on Permeability and MWCO
Polyethersulfone (PES) ultrafiltration membranes were fabricated by non-solvent-induced phase separation (NIPS) and characterized through water permeability and molecular weight cut-off (MWCO) measurements. The influence of polymer concentration, coagulation bath temperature, and casting thickness on membrane performance was investigated using accessible characterization methodologies. A total of 27 membrane fabrication experiments were conducted using three PES concentrations (18, 20, and 22 wt.%), three coagulation bath temperatures (6, 8, and 10 °C), and three nominal casting thicknesses (60, 75, and 90 μm). Water permeability ranged from approximately 9 to 80 L m−2 h−1 bar−1, demonstrating a strong influence of fabrication conditions on membrane performance. Polymer concentration was identified as the dominant factor controlling both permeability and MWCO. Increasing PES concentration produced membranes with lower permeability and lower MWCO values, consistent with the reduction in effective pore size, although direct morphological characterization was beyond the scope of this study. Coagulation bath temperature significantly affected both permeability and selectivity, whereas casting thickness significantly affected permeability but showed no significant influence on MWCO. Statistical analysis further revealed a significant interaction between polymer concentration and coagulation bath temperature for MWCO. The results demonstrated a clear permeability–selectivity trade-off characteristic of ultrafiltration membranes prepared by NIPS. Furthermore, the combined use of permeability and MWCO measurements provided sufficient information to identify the effects of fabrication parameters on membrane performance, highlighting the usefulness of accessible characterization methodologies for membrane development, optimization, and technology transfer.
Open AccessAccessible Fabrication and Functional Characterization of Polyethersulfone Ultrafiltration Membranes: Effects of NIPS Processing Conditions on Permeability and MWCO
Polyethersulfone (PES) ultrafiltration membranes were fabricated by non-solvent-induced phase separation (NIPS) and characterized through water permeability and molecular weight cut-off (MWCO) measurements. The influence of polymer concentration, coagulation bath temperature, and casting thickness on membrane performance was investigated using accessible characterization methodologies. A total of 27 membrane fabrication experiments were conducted using three PES concentrations (18, 20, and 22 wt.%), three coagulation bath temperatures (6, 8, and 10 °C), and three nominal casting thicknesses (60, 75, and 90 μm). Water permeability ranged from approximately 9 to 80 L m−2 h−1 bar−1, demonstrating a strong influence of fabrication conditions on membrane performance. Polymer concentration was identified as the dominant factor controlling both permeability and MWCO. Increasing PES concentration produced membranes with lower permeability and lower MWCO values, consistent with the reduction in effective pore size, although direct morphological characterization was beyond the scope of this study. Coagulation bath temperature significantly affected both permeability and selectivity, whereas casting thickness significantly affected permeability but showed no significant influence on MWCO. Statistical analysis further revealed a significant interaction between polymer concentration and coagulation bath temperature for MWCO. The results demonstrated a clear permeability–selectivity trade-off characteristic of ultrafiltration membranes prepared by NIPS. Furthermore, the combined use of permeability and MWCO measurements provided sufficient information to identify the effects of fabrication parameters on membrane performance, highlighting the usefulness of accessible characterization methodologies for membrane development, optimization, and technology transfer.
- Open Access
- 12 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (16) , 7270
Lead Removal by Reverse Osmosis: Seeking Sustainability in the Operation of Advanced Technologies: A Preliminary Study
Nowadays, stricter control and rigorous landfill standards are being promoted in industries that produce liquid discharges into the environment. The development of innovative and sustainable technologies to remove lead from water is of great importance in all aspects, with safe recycling practices, especially with high lead concentrations, such as in mining activities. The experiment was conducted at a reverse osmosis (RO) pilot plant, operated at low impact pressures and designed to optimize energy savings without compromising separation efficiency. By reducing energy consumption, the process not only lowers operational costs but also minimizes the environmental impact associated with high energy consumption. The results show that RO operated at low pressures successfully removed 99.75% of lead at a pressure of 10 bar and a flux of 67.44 L/m2·h, demonstrating a practical and sustainable solution for lead removal at pressures of 5, 7.5, and 10 bar, which are considered low pressures since they are below 1.0 MPa. In addition to its high removal efficiency, the process offers significant advantages in terms of energy efficiency and a reduced carbon footprint. Enhancing the efficiency of this technology is crucial, not only to decrease operational costs but also to reduce environmental impact.
- 12 August 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (16) , 7270
Open AccessLead Removal by Reverse Osmosis: Seeking Sustainability in the Operation of Advanced Technologies: A Preliminary Study
Nowadays, stricter control and rigorous landfill standards are being promoted in industries that produce liquid discharges into the environment. The development of innovative and sustainable technologies to remove lead from water is of great importance in all aspects, with safe recycling practices, especially with high lead concentrations, such as in mining activities. The experiment was conducted at a reverse osmosis (RO) pilot plant, operated at low impact pressures and designed to optimize energy savings without compromising separation efficiency. By reducing energy consumption, the process not only lowers operational costs but also minimizes the environmental impact associated with high energy consumption. The results show that RO operated at low pressures successfully removed 99.75% of lead at a pressure of 10 bar and a flux of 67.44 L/m2·h, demonstrating a practical and sustainable solution for lead removal at pressures of 5, 7.5, and 10 bar, which are considered low pressures since they are below 1.0 MPa. In addition to its high removal efficiency, the process offers significant advantages in terms of energy efficiency and a reduced carbon footprint. Enhancing the efficiency of this technology is crucial, not only to decrease operational costs but also to reduce environmental impact.