Risha Na
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Risha Na has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Bo Peng
Electric Power Research Institute of State Grid Anhui Electric Power Co., Ltd
2 shared publicationsFeng Zhang
Electric Power Research Institute of State Grid Anhui Electric Power Co., Ltd
2 shared publicationsHui Sun
State Grid Anhui Electric Power Co., Ltd
2 shared publicationsJing Sun
Anhui University
2 shared publicationsJun Tao
Anhui University
2 shared publications- Jun Tao
Anhui University
2 shared publications
Latest Publications
- Open Access
Local Faulted-Section Identification for Pole-to-Pole Faults in MVDC Ring Networks Using Hybrid DC Circuit-Breaker Commutation Characteristics
Fast and selective faulted-section identification is challenging in multiterminal medium-voltage DC (MVDC) ring networks because the initial fault transient is affected by converter dynamics, fault resistance, line parameters, and multiple feeding paths. This paper proposes a local identification method for pole-to-pole faults in a four-terminal ±10 kV modular multilevel converter (MMC)-based MVDC ring network, using hybrid DC circuit-breaker (HCB) commutation characteristics. The breaker-current magnitude is used to initiate hybrid DC circuit breaker operation. The identification feature is the magnitude of the mechanical-switch (MS) current slope estimated during the passive intervals of the clamped commutation stage. This feature is used to classify faults as in-zone or out-of-zone. An in-zone fault is confirmed when three consecutive valid slope estimates satisfy the threshold criterion. Because only local HCB measurements and control signals are required for online identification, the method does not rely on interterminal communication or time synchronization. Offline threshold setting, however, requires the network topology and component parameters. After classification, the HCBs bounding the faulted line continue the interruption process, whereas triggered out-of-zone HCBs maintain semiconductor conduction and subsequently reclose their MSs. PSCAD/EMTDC simulations on a four-terminal ±10 kV MVDC ring network demonstrate correct faulted-section identification at the end of a 200 μs decision interval measured from local HCB triggering, using a baseline protection sampling interval of 1 μs, over the tested fault locations and fault resistance. Additional sampling-interval tests show no observed identification failures at 1 and 2 μs for the evaluated cases, whereas failures occur at 5 μs. Additional bounded measurement-noise tests show correct discrimination for the benchmark fault at the tested nominal noise levels up to 1% for the selected noise realizations. These results demonstrate the feasibility for the studied configuration; broader parameter variations and practical measurement and execution constraints require further validation.
Open AccessLocal Faulted-Section Identification for Pole-to-Pole Faults in MVDC Ring Networks Using Hybrid DC Circuit-Breaker Commutation Characteristics
Fast and selective faulted-section identification is challenging in multiterminal medium-voltage DC (MVDC) ring networks because the initial fault transient is affected by converter dynamics, fault resistance, line parameters, and multiple feeding paths. This paper proposes a local identification method for pole-to-pole faults in a four-terminal ±10 kV modular multilevel converter (MMC)-based MVDC ring network, using hybrid DC circuit-breaker (HCB) commutation characteristics. The breaker-current magnitude is used to initiate hybrid DC circuit breaker operation. The identification feature is the magnitude of the mechanical-switch (MS) current slope estimated during the passive intervals of the clamped commutation stage. This feature is used to classify faults as in-zone or out-of-zone. An in-zone fault is confirmed when three consecutive valid slope estimates satisfy the threshold criterion. Because only local HCB measurements and control signals are required for online identification, the method does not rely on interterminal communication or time synchronization. Offline threshold setting, however, requires the network topology and component parameters. After classification, the HCBs bounding the faulted line continue the interruption process, whereas triggered out-of-zone HCBs maintain semiconductor conduction and subsequently reclose their MSs. PSCAD/EMTDC simulations on a four-terminal ±10 kV MVDC ring network demonstrate correct faulted-section identification at the end of a 200 μs decision interval measured from local HCB triggering, using a baseline protection sampling interval of 1 μs, over the tested fault locations and fault resistance. Additional sampling-interval tests show no observed identification failures at 1 and 2 μs for the evaluated cases, whereas failures occur at 5 μs. Additional bounded measurement-noise tests show correct discrimination for the benchmark fault at the tested nominal noise levels up to 1% for the selected noise realizations. These results demonstrate the feasibility for the studied configuration; broader parameter variations and practical measurement and execution constraints require further validation.
- Open Access
Promoting the Green Transformation of Traditional Ships in Anhui Province: A Model Prediction Cost Analysis Algorithm for a New Electrification Transformation Scheme Using Lithium Iron Phosphate Battery
Promoting the green transformation of traditional diesel-powered ships is crucial for achieving carbon peaking and carbon neutrality goals. This study focuses on diesel-engine ships operating in the inland river areas of Anhui Province, China. It proposes two electrification retrofit schemes based mainly on lithium iron phosphate (LIP) batteries: full electrification and diesel-engine redundancy. The economic and environmental impacts of these schemes are analyzed and compared with those of conventional diesel-powered ships. A cost prediction algorithm based on model prediction is proposed, supported by a mathematical model for cost analysis. Results indicate that for electric tankers to become economically viable, battery costs must decrease through yearly improvements in energy density and reduced degradation rates. Additionally, government support is essential, such as raising carbon prices and providing subsidies—either an annual operational subsidy of CNY 80,000 or an initial construction subsidy of CNY 500,000. The study concludes that continued advances in battery technology, together with policy and financial support, will accelerate the large-scale electrification of ships.
Open AccessPromoting the Green Transformation of Traditional Ships in Anhui Province: A Model Prediction Cost Analysis Algorithm for a New Electrification Transformation Scheme Using Lithium Iron Phosphate Battery
Promoting the green transformation of traditional diesel-powered ships is crucial for achieving carbon peaking and carbon neutrality goals. This study focuses on diesel-engine ships operating in the inland river areas of Anhui Province, China. It proposes two electrification retrofit schemes based mainly on lithium iron phosphate (LIP) batteries: full electrification and diesel-engine redundancy. The economic and environmental impacts of these schemes are analyzed and compared with those of conventional diesel-powered ships. A cost prediction algorithm based on model prediction is proposed, supported by a mathematical model for cost analysis. Results indicate that for electric tankers to become economically viable, battery costs must decrease through yearly improvements in energy density and reduced degradation rates. Additionally, government support is essential, such as raising carbon prices and providing subsidies—either an annual operational subsidy of CNY 80,000 or an initial construction subsidy of CNY 500,000. The study concludes that continued advances in battery technology, together with policy and financial support, will accelerate the large-scale electrification of ships.
- 27 April 2025
- Published by Springer Nature
- p. 190-197
Comparison of Two Modulation Strategies of MMC in DC Transmission
- 27 April 2025
- Published by Springer Nature
- p. 190-197
Comparison of Two Modulation Strategies of MMC in DC Transmission
- 27 April 2025
- Published by Springer Nature
- p. 198-205
Summary of Grounding Location Methods for Unipolar Faults
- 27 April 2025
- Published by Springer Nature
- p. 198-205
Summary of Grounding Location Methods for Unipolar Faults
- 27 April 2025
- Published by Springer Nature
- p. 339-345
Design of PMSM Driver System Based on SiC MOSFET