Dipesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dipesh has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Manindra Bhushan
Department of Radiation Oncology, Division of Medical Physics, Rajiv Gandhi Cancer Institute and Research Center, New Delhi, India
8 shared publications - Sandeep Singh
Department of Radiation Oncology, Amrita School of Medicine, Amrita Vishwavidyapeetham, Faridabad, India
7 shared publications - Abhay Kumar Singh
Department of Physics, GLA University, Mathura, India
6 shared publications - Supratik Sen
Department of Radiation Oncology, Dr. B. Borooah Cancer Institute, Guwahati, India
6 shared publications - Mahipal
Department of Physics, GLA University, Mathura, India
3 shared publications - Munish Gairola
Department of Radiation Oncology, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India
3 shared publications
Latest Publications
- 14 October 2026
- Published by Springer Nature in Health and Technology
- p. 1-9
Media exposure, misinformation and patient advocacy in cancer care: a cross-sectional survey-based study from India
- 14 October 2026
- Published by Springer Nature in Health and Technology
- p. 1-9
Media exposure, misinformation and patient advocacy in cancer care: a cross-sectional survey-based study from India
- 7 October 2026
- Published by Springer Nature in Strahlentherapie und Onkologie
- p. 1-14
Tightening the gradient: ten years of dosimetric refinement in head and neck reirradiation
- 7 October 2026
- Published by Springer Nature in Strahlentherapie und Onkologie
- p. 1-14
Tightening the gradient: ten years of dosimetric refinement in head and neck reirradiation
- 5 September 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1684-1694
Site-specific performance and complexity-dependent risk assessment of patient-specific quality assurance using a 2D array detector in CyberKnife radiosurgery
- 5 September 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1684-1694
Site-specific performance and complexity-dependent risk assessment of patient-specific quality assurance using a 2D array detector in CyberKnife radiosurgery
- 24 August 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1602-1616
End-to-end technical validation of multi-isocenter total body irradiation using an anthropomorphic phantom
The objective of this study is to perform an end-to-end (E2E) technical validation of a total body irradiation (TBI) workflow using an anthropomorphic phantom, integrating simulation, treatment planning, patient-specific quality assurance, and phantom-based dosimetry to ensure accurate and reproducible dose delivery. A full E2E test was performed using the Rando Phantom and Varian Eclipse TPS. CT scans were acquired in head-first supine (HFS) and feet-first supine (FFS) orientations and registered to simulate full-body imaging. Treatment plans were optimized for both orientations, with specific gradient dose regions defined for overlap zones. ArcCHECK and OSLDs were used for pre-treatment and phantom-embedded dosimetric verification, respectively. Cone Beam CT (CBCT) assessed positional accuracy across eight treatment fractions. Dose discrepancies and alignment errors were evaluated across anatomical regions. HU comparison between the CT console and TPS revealed only minor deviations, all within ± 6 HU, supporting the consistency of HU representation in the TPS. Gamma passing rates exceeded 97% across most regions. OSLD dose differences remained within ± 2.5% for most sites, except thorax and overlap zones, which reached ± 4.8%. CBCT-based setup verification demonstrated sub-millimeter alignment deviations across fractions, indicating consistent positional accuracy. E2E validation using the Rando Phantom supports technical accuracy and consistency in the TBI workflow. Notable dose variations in overlap and heterogeneous regions highlight the need for enhanced QA in complex geometries. The findings support the technical feasibility and reproducibility of the workflow, while further patient-specific and motion-inclusive studies are required to establish broader clinical applicability.
- 24 August 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1602-1616
End-to-end technical validation of multi-isocenter total body irradiation using an anthropomorphic phantom
The objective of this study is to perform an end-to-end (E2E) technical validation of a total body irradiation (TBI) workflow using an anthropomorphic phantom, integrating simulation, treatment planning, patient-specific quality assurance, and phantom-based dosimetry to ensure accurate and reproducible dose delivery. A full E2E test was performed using the Rando Phantom and Varian Eclipse TPS. CT scans were acquired in head-first supine (HFS) and feet-first supine (FFS) orientations and registered to simulate full-body imaging. Treatment plans were optimized for both orientations, with specific gradient dose regions defined for overlap zones. ArcCHECK and OSLDs were used for pre-treatment and phantom-embedded dosimetric verification, respectively. Cone Beam CT (CBCT) assessed positional accuracy across eight treatment fractions. Dose discrepancies and alignment errors were evaluated across anatomical regions. HU comparison between the CT console and TPS revealed only minor deviations, all within ± 6 HU, supporting the consistency of HU representation in the TPS. Gamma passing rates exceeded 97% across most regions. OSLD dose differences remained within ± 2.5% for most sites, except thorax and overlap zones, which reached ± 4.8%. CBCT-based setup verification demonstrated sub-millimeter alignment deviations across fractions, indicating consistent positional accuracy. E2E validation using the Rando Phantom supports technical accuracy and consistency in the TBI workflow. Notable dose variations in overlap and heterogeneous regions highlight the need for enhanced QA in complex geometries. The findings support the technical feasibility and reproducibility of the workflow, while further patient-specific and motion-inclusive studies are required to establish broader clinical applicability.
- 24 February 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (2) , 1-13
Bridging precision and practice: dual validation of a high-resolution detector array for beam profiling and patient QA in robotic radiosurgery
This study assessed a high-resolution ionisation chamber-based PTW 1600SRS detector array (array) for beam profile analysis and patient-specific quality assurance (PSQA) in CyberKnife (CK) stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). The goal was to determine its suitability for small fields and non-isocentric delivery, which is unique to robotic platforms. Detector performance was examined for dose linearity, reproducibility, beam profiles, output factors, dose-rate dependence, and verification of the Iris collimator field size. Results were benchmarked against diode-based commissioning data. Clinical applicability was tested by retrospectively verifying 20 intracranial SRS and 20 extracranial SBRT plans using gamma analysis with criteria ranging from 3%/3 mm to 1%/1 mm, as well as 4%/1 mm. The detector showed strong dose linearity (R2 = 0.999) and stable reproducibility. Beam profiles matched commissioning values within 0.5 mm, and output factors agreed within 2% for most collimators, with a maximum deviation of 3% at 5 mm. Dose-rate variation remained within 2.5% across relevant SADs. Iris collimator field sizes were consistent with reference measurements. Clinical validation achieved high passing rates, all with tolerance limit of > 95%. It enables accurate beam characterization and reliable PSQA in CK treatments. This work provides the first combined evaluation of beam analysis and clinical validation for this detector on a robotic radiosurgery system, supporting its routine use in small-field quality assurance.
- 24 February 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (2) , 1-13
Bridging precision and practice: dual validation of a high-resolution detector array for beam profiling and patient QA in robotic radiosurgery
This study assessed a high-resolution ionisation chamber-based PTW 1600SRS detector array (array) for beam profile analysis and patient-specific quality assurance (PSQA) in CyberKnife (CK) stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). The goal was to determine its suitability for small fields and non-isocentric delivery, which is unique to robotic platforms. Detector performance was examined for dose linearity, reproducibility, beam profiles, output factors, dose-rate dependence, and verification of the Iris collimator field size. Results were benchmarked against diode-based commissioning data. Clinical applicability was tested by retrospectively verifying 20 intracranial SRS and 20 extracranial SBRT plans using gamma analysis with criteria ranging from 3%/3 mm to 1%/1 mm, as well as 4%/1 mm. The detector showed strong dose linearity (R2 = 0.999) and stable reproducibility. Beam profiles matched commissioning values within 0.5 mm, and output factors agreed within 2% for most collimators, with a maximum deviation of 3% at 5 mm. Dose-rate variation remained within 2.5% across relevant SADs. Iris collimator field sizes were consistent with reference measurements. Clinical validation achieved high passing rates, all with tolerance limit of > 95%. It enables accurate beam characterization and reliable PSQA in CK treatments. This work provides the first combined evaluation of beam analysis and clinical validation for this detector on a robotic radiosurgery system, supporting its routine use in small-field quality assurance.
- 31 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105711
Predicting patient setup shifts in daily radiotherapy using machine learning on phantom-based CBCT and kV/MV data
- 31 December 2025
- Published by Elsevier in Physica Medica
- Vol. 141, 105711
Predicting patient setup shifts in daily radiotherapy using machine learning on phantom-based CBCT and kV/MV data
- 11 September 2025
- Published by Elsevier in Clinical Oncology
- Vol. 47, 103936
Optimization and Quality Assurance of VMAT-Driven Lattice Radiotherapy in Large Tumors Across Anatomical Sites
- 11 September 2025
- Published by Elsevier in Clinical Oncology
- Vol. 47, 103936
Optimization and Quality Assurance of VMAT-Driven Lattice Radiotherapy in Large Tumors Across Anatomical Sites
- 6 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1127-1142
Comparative dosimetric analysis of base dose and gradient-based optimization in overlapping regions of extended target volumes using an anthropomorphic phantom
This study compares the dosimetric performance of Base Dose Optimization (BDO) and Gradient-Based Optimization (GBO) for extended target volumes in Total Body Irradiation (TBI). The focus is on overlapping regions using the Rando Phantom. The study evaluates dose distribution, conformity, homogeneity, and sensitivity to positional deviations. The Rando Phantom was used for treatment planning with both BDO and GBO plans. Positional shifts of ± 5 mm and ± 10 mm were introduced to assess uncertainties. Dosimetric metrics included mean dose, minimum dose, maximum dose, homogeneity index (HI), and conformity index (CI). Positional deviations and their impact on dose variations were analyzed. Quality assurance was performed using OSLDs and an array detector. The BDO plan delivered higher mean doses (103.6%–108.7%) and hotspot values, with a maximum of 133.7%. In contrast, the GBO plan produced a more uniform dose distribution (99.6%–100.3%) with lower hotspots, peaking at 112%. The BDO plan achieved better uniformity (HI 0.025–0.103) and higher conformity (CI 0.938–0.981). The GBO plan showed greater variability (HI 0.143–0.253) and slightly lower conformity (CI 0.941–0.964). Positional shifts revealed that the BDO plan was highly sensitive, with overdoses of + 46.60% and underdoses of − 47.29%. The GBO plan showed smaller deviations (+ 11.62% overdose, − 11.73% underdose). Gamma analysis demonstrated higher pass rates for the GBO plan. The BDO plan excels in target coverage and conformity but is sensitive to positional shifts. The GBO plan offers better uniformity and robustness, supporting its use in complex clinical scenarios. Further refinement of both approaches could improve clinical applicability and patient outcomes.
- 6 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1127-1142
Comparative dosimetric analysis of base dose and gradient-based optimization in overlapping regions of extended target volumes using an anthropomorphic phantom
This study compares the dosimetric performance of Base Dose Optimization (BDO) and Gradient-Based Optimization (GBO) for extended target volumes in Total Body Irradiation (TBI). The focus is on overlapping regions using the Rando Phantom. The study evaluates dose distribution, conformity, homogeneity, and sensitivity to positional deviations. The Rando Phantom was used for treatment planning with both BDO and GBO plans. Positional shifts of ± 5 mm and ± 10 mm were introduced to assess uncertainties. Dosimetric metrics included mean dose, minimum dose, maximum dose, homogeneity index (HI), and conformity index (CI). Positional deviations and their impact on dose variations were analyzed. Quality assurance was performed using OSLDs and an array detector. The BDO plan delivered higher mean doses (103.6%–108.7%) and hotspot values, with a maximum of 133.7%. In contrast, the GBO plan produced a more uniform dose distribution (99.6%–100.3%) with lower hotspots, peaking at 112%. The BDO plan achieved better uniformity (HI 0.025–0.103) and higher conformity (CI 0.938–0.981). The GBO plan showed greater variability (HI 0.143–0.253) and slightly lower conformity (CI 0.941–0.964). Positional shifts revealed that the BDO plan was highly sensitive, with overdoses of + 46.60% and underdoses of − 47.29%. The GBO plan showed smaller deviations (+ 11.62% overdose, − 11.73% underdose). Gamma analysis demonstrated higher pass rates for the GBO plan. The BDO plan excels in target coverage and conformity but is sensitive to positional shifts. The GBO plan offers better uniformity and robustness, supporting its use in complex clinical scenarios. Further refinement of both approaches could improve clinical applicability and patient outcomes.
- 18 August 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1055-1063
Impact of dynamic jaw width adjustment in tomotherapy on hippocampus sparing and treatment efficiency in whole-brain radiotherapy
The aim of this study is to evaluate the impact of dynamic jaw width adjustment in tomotherapy on hippocampal sparing, target dose conformity, and treatment efficiency in hippocampal-avoidance whole-brain radiotherapy (HA-WBRT), in accordance with RTOG 0933 guidelines. A retrospective study of 60 patients treated with HA-WBRT was conducted. CT-MRI fusion facilitated accurate hippocampal delineation. Treatment plans were created using Accuray Precision TPS and delivered on the Radixact Tomotherapy system with three jaw widths (1 cm, 2.5 cm, and 5 cm), fixed pitch (0.215), and modulation factor (3.0). The prescription dose was 30 Gy in 10 fractions. Evaluation metrics included PTV coverage (D98%, V95%, D2%, Dmax), homogeneity index (HI), conformity index (CI), hippocampal and lens doses, and beam-on time (BOT). Plan verification was performed with ArcCHECK using 3%/3 mm and 3%/2 mm gamma criteria. The 1 cm jaw achieved the best PTV coverage (D98% = 29.22 Gy, V95% = 98.71%), with HI = 0.09, CI = 0.99, and superior hippocampal sparing (Dmax = 14.91 Gy, Dmin = 7.57 Gy), but had the longest BOT (1165 s). Wider jaws (2.5 cm, 5 cm) reduced BOT (480 s, 280 s) but slightly compromised conformity and increased OAR doses, all within limits. Jaw width selection in Helical Tomotherapy influences dose distribution characteristics and treatment delivery efficiency in hippocampus-sparing WBRT. A 1 cm jaw width provides superior dosimetric conformity and enhanced hippocampal sparing, albeit at the cost of increased BOT. In contrast, wider jaw widths (2.5 cm and 5 cm) improve delivery efficiency but result in modest reductions in dose precision and organ-at-risk sparing. Therefore, jaw width selection should be carefully individualized based on clinical objectives, balancing the trade-off between organ preservation and treatment efficiency.
- 18 August 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1055-1063
Impact of dynamic jaw width adjustment in tomotherapy on hippocampus sparing and treatment efficiency in whole-brain radiotherapy
The aim of this study is to evaluate the impact of dynamic jaw width adjustment in tomotherapy on hippocampal sparing, target dose conformity, and treatment efficiency in hippocampal-avoidance whole-brain radiotherapy (HA-WBRT), in accordance with RTOG 0933 guidelines. A retrospective study of 60 patients treated with HA-WBRT was conducted. CT-MRI fusion facilitated accurate hippocampal delineation. Treatment plans were created using Accuray Precision TPS and delivered on the Radixact Tomotherapy system with three jaw widths (1 cm, 2.5 cm, and 5 cm), fixed pitch (0.215), and modulation factor (3.0). The prescription dose was 30 Gy in 10 fractions. Evaluation metrics included PTV coverage (D98%, V95%, D2%, Dmax), homogeneity index (HI), conformity index (CI), hippocampal and lens doses, and beam-on time (BOT). Plan verification was performed with ArcCHECK using 3%/3 mm and 3%/2 mm gamma criteria. The 1 cm jaw achieved the best PTV coverage (D98% = 29.22 Gy, V95% = 98.71%), with HI = 0.09, CI = 0.99, and superior hippocampal sparing (Dmax = 14.91 Gy, Dmin = 7.57 Gy), but had the longest BOT (1165 s). Wider jaws (2.5 cm, 5 cm) reduced BOT (480 s, 280 s) but slightly compromised conformity and increased OAR doses, all within limits. Jaw width selection in Helical Tomotherapy influences dose distribution characteristics and treatment delivery efficiency in hippocampus-sparing WBRT. A 1 cm jaw width provides superior dosimetric conformity and enhanced hippocampal sparing, albeit at the cost of increased BOT. In contrast, wider jaw widths (2.5 cm and 5 cm) improve delivery efficiency but result in modest reductions in dose precision and organ-at-risk sparing. Therefore, jaw width selection should be carefully individualized based on clinical objectives, balancing the trade-off between organ preservation and treatment efficiency.