JCJane Wambui Chege

Jane Wambui Chege

*This is an algorithmically generated author record based on publicly available information.

Jane Wambui Chege has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrating ocean thermal energy conversion with circular economy principles: Optimal sizing and dispatch for typhoon-prone island grids

    by Jane Wambui Chege

    Small island grids must simultaneously reduce electricity cost, withstand extreme weather, and advance circular resource use, yet no optimization framework integrates these objectives for typhoon-prone systems. This study develops a multi-objective sizing and dispatch framework for a hybrid island grid integrating ocean thermal energy conversion (OTEC), floating photovoltaic generation (FPV), second-life battery storage (SLB), and diesel backup, applied to Ishigaki Island, Okinawa, Japan, over a full 8,760-hour horizon, which simultaneously minimizes a revenue-adjusted levelized cost of energy (LCOE-R), maximizes a circularity index (CI), and maximizes a typhoon resilience index (RI). OTEC cold-water byproducts are modeled as capacity-constrained, market-absorption-limited revenue streams; SLB degradation and replacement are embedded over the project lifetime; and typhoon-window resilience is evaluated separately from annual reliability through FPV shutdown and OTEC derating during storms. The method is evaluated across four cases: diesel only, FPV-SLB-diesel, OTEC-diesel, and OTEC-FPV-SLB-diesel. The fully integrated case provides the strongest overall trade-off, reducing LCOE-R from 0.360 to 0.066~USD/kWh and raising CI from 0.009 to 0.532 relative to the diesel-only case, while annual diesel generation falls from 310.0 to 23.8~GWh, a 92.3% reduction. Byproduct revenue offsets 0.234 USD/kWh of gross cost, identifying valorization rather than renewable electricity as the primary economic enabler. However, the integrated case records a lower mean typhoon-window RI (0.608) than the diesel-only case, as FPV shutdown, OTEC derating, and reduced backup coincide. These findings establish that OTEC byproduct markets, storage degradation, and storm-period adequacy must be treated as explicit design constraints, since strong annual performance does not guarantee storm-period resilience.

  • Open Access

    Enhancing wind power forecasting through dynamic air density integration: A machine learning framework with operational and economic implications

    by Chijioke Godswill Ilechukwu, Soichiro Ueda, Jane Wambui Chege, Nyam Jargalsaikhan, Tomonobu Senjyu

    Accurate wind turbine power prediction underpins effective grid management, maintenance planning, and energy market participation. Yet most operational forecasting models rely on a fixed value of 1.225 kg/m³ for air density despite real atmospheric density varying with temperature, pressure, and humidity in ways that directly alter the kinetic energy available to a turbine rotor. This study proposes an improved machine learning forecasting framework that dynamically calculates and incorporates real-time air density from meteorological variables available in Supervisory Control and Data Acquisition (SCADA) systems. Using 31,255 ten-minute operational records from a UK wind farm (January–August 2020), a Random Forest Regression (RFR) model was developed following a rigorous four-stage preprocessing pipeline including IQR-based outlier removal and linear interpolation of short data gaps. The model was benchmarked against Linear Regression, Gradient Boosting Machines, and XGBoost. The proposed framework achieves R² = 0.989 and reduces RMSE from 195.7 W to 71.6 W (63% improvement) relative to the linear regression baseline. MAE is reduced from 132 W to 51 W. Seasonal analysis reveals monthly RMSE improvements ranging from 26% in January (winter) to 66.5% in June (summer), coinciding with periods of greatest atmospheric variability. SHAP analysis confirms that wind speed (60%) and dynamically computed air density (27%) are the two dominant predictors, consistent with the aerodynamic relation P ∝ ρv³. The framework requires no hardware modifications; air density is computed in real time from existing SCADA sensors, making dynamic density integration a practical and low-cost enhancement for existing wind farm infrastructure.

  • Open Access

    Long-term thermal power reduction in Okinawa’s island grid: Risk-aware multi-objective optimization of second-life batteries with degradation and circularity assessment

    by Jane Wambui Chege, Mark Kipngetich Kiptoo, Akie Uehara, Tomonobu Senjyu, M.H. Elkholy

    Okinawa, Japan, is an island with a grid heavily dependent on imported liquefied natural gas (LNG), oil, and coal. This exposes it to volatile global fuel prices and a high risk of greenhouse gas emissions. Simultaneously, the rapid adoption of electric vehicles in Japan creates challenges related to the disposal of retired batteries. This study examines the potential of second-life batteries (SLB) to reduce reliance on thermal power and to improve risk-aware planning for the Okinawa grid. A multi-objective optimization framework employing the Non-Dominated Sorting Genetic Algorithm III is applied to minimize total cost intensity (TCOI), operational emissions intensity (OEI), and Conditional Value-at-Risk at the 95\% confidence level (CVaR$_{0.95}$). Battery degradation and replacement behavior are explicitly modeled, and a post-optimization circularity assessment quantifies material mass flows, recovery potential, and avoided virgin material demand arising from battery second-life and replacement dynamics. Four scenarios are examined, including thermal-dominated systems and hybrid configurations with photovoltaic, wind, and battery storage using either SLBs or new batteries. The optimal SLB-based configuration achieved a TCOI of 184.21 USD/MWh, an OEI of 0.44 tCO$_2$/MWh, and a CVaR$_{0.95}$ of 85.29 USD/MWh. The scenario also attained a 7 percentage point higher circularity score relative to the new battery scenario and a 17\% thermal reduction relative to the baseline scenario. These findings demonstrate that second-life batteries provide a cost-effective and circular pathway for reducing thermal dependence in island power systems. The proposed framework is transferable to other islands and remote grids.