Tim Fleiner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tim Fleiner has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Nicole Rosskothen-Kuhl
Neurobiological Research Laboratory, Section for Experimental and Clinical Otology Department of Otorhinolaryngology Faculty of Medicine Medical Center – University of Freiburg Freiburg Germany
4 shared publications - Jan Wilbert Hendrik Schnupp
Gerald Choa Neuroscience Institute, Chinese University of Hong Kong, Hong Kong S.A.R
3 shared publications - Sarah Buchholz
Faculty of Biology University of Freiburg Freiburg Germany
2 shared publications - Shiyi Fang
Department of Neuroscience City University of Hong Kong Hong Kong SAR China
2 shared publications - Alexa N. Buck
City University of Hong Kong
1 shared publication - Armin Bartels
Laboratory for Microelectronics, Department of Microsystems Engineering (IMTEK), University of Freiburg, Freiburg im Breisgau, Germany
1 shared publication
Latest Publications
- Open Access
- 22 April 2026
- Published by Wiley in The Journal of Physiology
- Vol. 604 (10) , 3875-3894
Neurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences
Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. Although CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioural study on early deafened, bilaterally CI‐implanted rats that pulse timing ITDs completely dominate ITD perception, whereas sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcomes in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. image Key points: Current bilateral cochlear implants mostly provide time cues of arriving sound in the envelope of stimulation rather than in the timing of pulses. A behavioural study on cochlear implanted rats has shown that pulse timing dominates binaural hearing. Here we examined the neural sensitivity to independent changes in time cues presented on the envelope or pulse timing, respectively, in rats with bilateral cochlear implants and different hearing experiences. Auditory midbrain neurons were consistently more sensitive to changes in pulse timing rather than envelope, irrespective of stimulus pulse rate, modulation rate or an animal's hearing experience.
- 22 April 2026
- Published by Wiley in The Journal of Physiology
- Vol. 604 (10) , 3875-3894
Open AccessNeurophysiological sensitivity to envelope and pulse timing interaural time differences in cochlear implanted rats with different hearing experiences
Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. Although CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioural study on early deafened, bilaterally CI‐implanted rats that pulse timing ITDs completely dominate ITD perception, whereas sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcomes in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. image Key points: Current bilateral cochlear implants mostly provide time cues of arriving sound in the envelope of stimulation rather than in the timing of pulses. A behavioural study on cochlear implanted rats has shown that pulse timing dominates binaural hearing. Here we examined the neural sensitivity to independent changes in time cues presented on the envelope or pulse timing, respectively, in rats with bilateral cochlear implants and different hearing experiences. Auditory midbrain neurons were consistently more sensitive to changes in pulse timing rather than envelope, irrespective of stimulus pulse rate, modulation rate or an animal's hearing experience.
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
When the First Pulse Fades: 75% Reduction in Precedence Effect in Cochlear Implanted Rats
It is widely known that users of cochlear implants (CIs) often show deficits in binaural hearing. In particular, interaural time difference (ITD) discrimination tends to be substantially worse in CI users. However, only very few studies have investigated how CI stimulation affects the “precedence effect” (PE), and how this might be affected by abnormal hearing experience during development. We performed behavioral experiments to measure temporal weighting functions (TWFs) to quantify the PE in three different cohorts of rats: normally hearing (NH) acoustically stimulated, neonatally deafened (ND) CI-stimulated, and adult deafened (AD) CI-stimulated animals. Lateralization responses were recorded to bursts of eight stimulus pulses in which the ITD of each pulse varied independently, and probit analysis revealed the perceptual weight of each pulse. The NH and ND-CI cohorts were tested at 50, 300, and 900 pps; the AD-CI animals were tested only at 300 pps. The NH animals show a pronounced “onset dominance” at higher pulse rates, that is, the weighting of the first pulse was much larger than for subsequent pulses, exactly as one would expect given previous studies on human listeners. In contrast, the TWFs for the ND-CI and AD-CI animals were much flatter, with a reduction of onset dominance by ∼75%, especially for higher pulse rates. Since neither of our CI cohorts had any experience of reverberation in their electric hearing, we interpret these results to indicate that the PE may require domain-specific experience to develop.
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessWhen the First Pulse Fades: 75% Reduction in Precedence Effect in Cochlear Implanted Rats
It is widely known that users of cochlear implants (CIs) often show deficits in binaural hearing. In particular, interaural time difference (ITD) discrimination tends to be substantially worse in CI users. However, only very few studies have investigated how CI stimulation affects the “precedence effect” (PE), and how this might be affected by abnormal hearing experience during development. We performed behavioral experiments to measure temporal weighting functions (TWFs) to quantify the PE in three different cohorts of rats: normally hearing (NH) acoustically stimulated, neonatally deafened (ND) CI-stimulated, and adult deafened (AD) CI-stimulated animals. Lateralization responses were recorded to bursts of eight stimulus pulses in which the ITD of each pulse varied independently, and probit analysis revealed the perceptual weight of each pulse. The NH and ND-CI cohorts were tested at 50, 300, and 900 pps; the AD-CI animals were tested only at 300 pps. The NH animals show a pronounced “onset dominance” at higher pulse rates, that is, the weighting of the first pulse was much larger than for subsequent pulses, exactly as one would expect given previous studies on human listeners. In contrast, the TWFs for the ND-CI and AD-CI animals were much flatter, with a reduction of onset dominance by ∼75%, especially for higher pulse rates. Since neither of our CI cohorts had any experience of reverberation in their electric hearing, we interpret these results to indicate that the PE may require domain-specific experience to develop.
- Open Access
Neurophysiological Sensitivity to Envelope and Pulse Timing Interaural Time Differences in Cochlear Implanted Rats with Different Hearing Experiences
Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. While CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioral study on early deafened, bilaterally CI-implanted rats that pulse timing ITDs completely dominate ITD perception, while sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcome in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. Graphical
Open AccessNeurophysiological Sensitivity to Envelope and Pulse Timing Interaural Time Differences in Cochlear Implanted Rats with Different Hearing Experiences
Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. While CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioral study on early deafened, bilaterally CI-implanted rats that pulse timing ITDs completely dominate ITD perception, while sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcome in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. Graphical
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 701-711
Stochastic Signal Processing Based Stimulation Artifact Cancellation in $\Delta\Sigma$ Neural FrontendThis paper presents a neural recorder frontend featuring electrical stimulation artifact cancellation by employing an adaptive LMS filter in the stochastic domain. The recording system comprises of a low-noise analog frontend and a 1st-order ΔΣ modulator. A power-efficient stochastic signal processor, occupying an area of 0.12 mm2, processes the ΔΣ modulator output bitstream to learn and compensate for artifacts induced by concurrent electrical stimulation. The proposed approach, validated on a prototype ASIC fabricated in 180 nm CMOS technology, has a total power consumption of 6.83 μW, with the stochastic signal processor consuming only 0.51 μW. Experimental results demonstrate that the system effectively suppresses peak-to-peak stimulation artifacts of 200 mV by approximately 33 dB over a 10 kHz bandwidth, establishing it as a novel state-of-the-art real-time artifact cancellation system. Furthermore, in-vitro validation for both biphasic and monophasic stimulation confirms its efficacy, with 74.3 mVpp artifacts from biphasic stimulation being attenuated by 25 dB.
- 22 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (4) , 701-711
Stochastic Signal Processing Based Stimulation Artifact Cancellation in $\Delta\Sigma$ Neural FrontendThis paper presents a neural recorder frontend featuring electrical stimulation artifact cancellation by employing an adaptive LMS filter in the stochastic domain. The recording system comprises of a low-noise analog frontend and a 1st-order ΔΣ modulator. A power-efficient stochastic signal processor, occupying an area of 0.12 mm2, processes the ΔΣ modulator output bitstream to learn and compensate for artifacts induced by concurrent electrical stimulation. The proposed approach, validated on a prototype ASIC fabricated in 180 nm CMOS technology, has a total power consumption of 6.83 μW, with the stochastic signal processor consuming only 0.51 μW. Experimental results demonstrate that the system effectively suppresses peak-to-peak stimulation artifacts of 200 mV by approximately 33 dB over a 10 kHz bandwidth, establishing it as a novel state-of-the-art real-time artifact cancellation system. Furthermore, in-vitro validation for both biphasic and monophasic stimulation confirms its efficacy, with 74.3 mVpp artifacts from biphasic stimulation being attenuated by 25 dB.