Begoña Garate Andikoetxea
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Begoña Garate Andikoetxea has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Maria Cruz Rodriguez-Oroz
Neurology Department, Clínica Universidad de Navarra, Pamplona, Spain
2 shared publications - Antonio Martin-Bastida
Department of Neurology Clínica Universidad de Navarra Pamplona Spain
1 shared publication - Carlos Alfredo Sanchez-Catasus
University of Michigan, United States
1 shared publication - Goizane Serna Requejo
Department of Neurology, Clínica Universidad de Navarra, Universidad de Navarra, Av. de Pío XII, 36, 31008 Pamplona, Navarra, Spain
1 shared publication - Lain Hermes Gonzalez-Quarante
Department of Neurosurgery Clinica Universidad de Navarra Pamplona Spain
1 shared publication - Lucas Soustelle
Aix Marseille Univ, CNRS, CRMBM, Marseille, France
1 shared publication
Latest Publications
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 317 (3) , e250669
T1/T2-weighted Ratio to Improve MRI-guided Focused Ultrasound–induced Chronic Lesion Contrast in Patients with Tremor Syndrome
T1/T2-weighted ratio imaging significantly improved the contrast of chronic thalamic lesions (ie, lesion visibility) induced by MRI-guided focused ultrasound for tremor treatment compared with T2-weighted imaging.
- 1 December 2025
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 317 (3) , e250669
T1/T2-weighted Ratio to Improve MRI-guided Focused Ultrasound–induced Chronic Lesion Contrast in Patients with Tremor Syndrome
T1/T2-weighted ratio imaging significantly improved the contrast of chronic thalamic lesions (ie, lesion visibility) induced by MRI-guided focused ultrasound for tremor treatment compared with T2-weighted imaging.
- Open Access
- 19 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70123
Neuromelanin Contrast Optimization and Improved Visualization of the Substantia Nigra in a 3D Gradient‐Echo Sequence With Magnetization Transfer
Neuromelanin (NM) magnetic resonance imaging has been used to evaluate the loss of melanized neurons in the substantia nigra, the main characteristic of Parkinson disease, typically by measuring the contrast ratio (CR) between the NM‐rich areas and the cerebral peduncles in the midbrain. Neuromelanin contrast can be generated by employing a 3D gradient‐echo (GRE) sequence with magnetization transfer (MT). In this work, we first evaluated the effect of the MT pulse frequency on the CR and contrast‐to‐noise ratio (CNR), analyzing a large frequency range from 500 to 100K Hz. Secondly, the impact of the 3D GRE sequence flip angle (FA) was evaluated using angles from 5° to 40°. Additionally, images were acquired both with and without MT for each FA, providing an opportunity to examine the effect of MT on tissue proton density, T1, and T2* values. Results showed that the highest CR and CNR were obtained for the lower MT frequencies (500–2000 Hz) and lower FAs (5°–10°). The lower FAs improved the visualization of the neuromelanin‐rich area in the substantia nigra and facilitated delineating its volume. In addition, this work showed that the MT pulse decreased the T1 and PD of the tissue. Furthermore, simulations supported the obtained in vivo results.
- 19 August 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (9) , e70123
Open AccessNeuromelanin Contrast Optimization and Improved Visualization of the Substantia Nigra in a 3D Gradient‐Echo Sequence With Magnetization Transfer
Neuromelanin (NM) magnetic resonance imaging has been used to evaluate the loss of melanized neurons in the substantia nigra, the main characteristic of Parkinson disease, typically by measuring the contrast ratio (CR) between the NM‐rich areas and the cerebral peduncles in the midbrain. Neuromelanin contrast can be generated by employing a 3D gradient‐echo (GRE) sequence with magnetization transfer (MT). In this work, we first evaluated the effect of the MT pulse frequency on the CR and contrast‐to‐noise ratio (CNR), analyzing a large frequency range from 500 to 100K Hz. Secondly, the impact of the 3D GRE sequence flip angle (FA) was evaluated using angles from 5° to 40°. Additionally, images were acquired both with and without MT for each FA, providing an opportunity to examine the effect of MT on tissue proton density, T1, and T2* values. Results showed that the highest CR and CNR were obtained for the lower MT frequencies (500–2000 Hz) and lower FAs (5°–10°). The lower FAs improved the visualization of the neuromelanin‐rich area in the substantia nigra and facilitated delineating its volume. In addition, this work showed that the MT pulse decreased the T1 and PD of the tissue. Furthermore, simulations supported the obtained in vivo results.