Rehab Khalid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rehab Khalid has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Emanuele Rezoagli
University of Milano-Bicocca
2 shared publications - Glasiele Cristina Alcala
Division of Respirology, Department of Medicine, University Health Network, Toronto, Canada
2 shared publications Jason H. T. Bates
University of Vermont
2 shared publications- Lorenzo Berra
Massachusetts General Hospital
2 shared publications Marcelo B. P. Amato
Universidade de São Paulo
2 shared publications- Marcus Victor
Aeronautics Institute of Technology
2 shared publications
Latest Publications
- Open Access
- 7 July 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 141 (2) , 423-432
Impact of Baydur Ratio Correction on the Reliability of Esophageal Pressure Measurement
Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position, remain unclear. In ten pigs, ΔPpl was measured using intrapleural balloon catheters, while Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland–Altman analysis. Additionally, we quantified the proportion of values with (ΔPes−ΔPpl) ≤ 1 cmH₂O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope 0.76 vs 0.50; r 0.81 vs 0.79, p<0.01) and increased values within ±1 cmH₂O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.
- 7 July 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 141 (2) , 423-432
Open AccessImpact of Baydur Ratio Correction on the Reliability of Esophageal Pressure Measurement
Tidal changes in esophageal pressure (ΔPes) are used as a surrogate for pleural pressure changes (ΔPpl) to assess chest wall mechanics. The Baydur ratio evaluates pressure transmission and guides catheter positioning. The effects of correcting ΔPes using the Baydur ratio on the accuracy of ΔPpl estimation and its dependence on ventilation mode, spontaneous inspiratory effort, and body position, remain unclear. In ten pigs, ΔPpl was measured using intrapleural balloon catheters, while Pes was recorded at three esophageal locations in supine and prone positions. Animals underwent controlled and assisted ventilation. Baydur ratios were derived during assisted ventilation and from external chest compressions during controlled ventilation. ΔPes before and after correction was compared with ΔPpl using mixed-effects models and Bland–Altman analysis. Additionally, we quantified the proportion of values with (ΔPes−ΔPpl) ≤ 1 cmH₂O. During assisted ventilation, ΔPes showed good agreement with posterior ΔPpl. Baydur correction improved scaling and association (slope 0.76 vs 0.50; r 0.81 vs 0.79, p<0.01) and increased values within ±1 cmH₂O from 29% to 45% when the Baydur ratio fell outside the accepted range. During controlled ventilation, ΔPes showed weaker association and wider limits of agreement, without improvement after correction. Similar patterns were observed in prone position. ΔPes more accurately reflected posterior ΔPpl during assisted ventilation. Baydur correction improves scaling and association, particularly when the Baydur ratio falls outside the accepted range, but does not improve and may worsen agreement during controlled ventilation.
- Top Cited Papers
- 1 September 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (3) , 849-862
Biomechanical implications of mass loading in a swine model of acute hypoxemic respiratory failure
In a ventilated swine model, we isolated the mechanical effects of mass loading from those of lung injury. Despite optimization, positive end-expiratory pressure (PEEP) could not restore baseline pulmonary compliance or lung volumes in either healthy or injured lungs. Partitioned respiratory mechanics and imaging reveal that geometric constraints and load-induced airway closure, demonstrated here for the first time in injured swine, may limit the effectiveness of recruitment maneuvers and optimized PEEP in mass-loaded lungs.
- 1 September 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (3) , 849-862
Top Cited PapersBiomechanical implications of mass loading in a swine model of acute hypoxemic respiratory failure
In a ventilated swine model, we isolated the mechanical effects of mass loading from those of lung injury. Despite optimization, positive end-expiratory pressure (PEEP) could not restore baseline pulmonary compliance or lung volumes in either healthy or injured lungs. Partitioned respiratory mechanics and imaging reveal that geometric constraints and load-induced airway closure, demonstrated here for the first time in injured swine, may limit the effectiveness of recruitment maneuvers and optimized PEEP in mass-loaded lungs.
- Open Access
- 25 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (11) , 5691-5695
Acute gastric volvulus in a pediatric patient: A rare case report
- 25 August 2025
- Published by Elsevier in Radiology Case Reports
- Vol. 20 (11) , 5691-5695
Open AccessAcute gastric volvulus in a pediatric patient: A rare case report
- 25 July 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1736-1747
Clinical applications of portable CT scanners
Portable Computed Tomography (CT) scanners have revolutionized diagnostic imaging by bringing advanced imaging capabilities directly to the point of care in critical settings such as intensive care units, operating rooms, ambulances, and other resource-limited environments. Integrating portable CT into clinical workflows improves patient outcomes through immediate, on-site imaging, eliminating the risks and delays associated with intra-hospital transportation. These systems are indispensable in critical care, reducing complications and time to diagnosis while enabling timely interventions for life-threatening conditions such as intracranial hemorrhage. Portable CT scanners are also transforming prehospital care, particularly in mobile stroke units, where they facilitate rapid diagnosis and treatment of strokes. This review examines the fundamentals of portable CT technology and its transformative role in various clinical scenarios, such as ICUs and intraoperative imaging. It traces the evolution of CT from stationary energy integrating detector-based systems to portable photon counting detector-based systems, highlighting the advantages of this technological transition. Key benefits include reduced patient complications, enhanced spatial resolution, improved diagnostic accuracy, lower radiation doses, and superior material differentiation, illustrated through clinical examples. As innovation advances in detector design and artificial intelligence, portable CT scanners are expected to grow further, expanding their clinical applications and solidifying their role as essential tools in modern diagnostic radiology.
- 25 July 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1736-1747
Clinical applications of portable CT scanners
Portable Computed Tomography (CT) scanners have revolutionized diagnostic imaging by bringing advanced imaging capabilities directly to the point of care in critical settings such as intensive care units, operating rooms, ambulances, and other resource-limited environments. Integrating portable CT into clinical workflows improves patient outcomes through immediate, on-site imaging, eliminating the risks and delays associated with intra-hospital transportation. These systems are indispensable in critical care, reducing complications and time to diagnosis while enabling timely interventions for life-threatening conditions such as intracranial hemorrhage. Portable CT scanners are also transforming prehospital care, particularly in mobile stroke units, where they facilitate rapid diagnosis and treatment of strokes. This review examines the fundamentals of portable CT technology and its transformative role in various clinical scenarios, such as ICUs and intraoperative imaging. It traces the evolution of CT from stationary energy integrating detector-based systems to portable photon counting detector-based systems, highlighting the advantages of this technological transition. Key benefits include reduced patient complications, enhanced spatial resolution, improved diagnostic accuracy, lower radiation doses, and superior material differentiation, illustrated through clinical examples. As innovation advances in detector design and artificial intelligence, portable CT scanners are expected to grow further, expanding their clinical applications and solidifying their role as essential tools in modern diagnostic radiology.