Adrienne D. Füredi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Adrienne D. Füredi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Katsuo Kurabayashi
Department of Biomedical Engineering, Tandon School of Engineering, New York University, Brooklyn, NY, USA
2 shared publications - Yujing Song
Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA.
2 shared publications - Andrew Stephens
Department of Mechanical Engineering, University of Michigan, Ann Arbor, USA
1 shared publication - Benjamin H. Singer
Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, United States
1 shared publication - Heidi Rosanna Flori
Department of Pediatrics, Division of Critical Care Medicine, University of Michigan, Ann Arbor, MI, USA
1 shared publication Huiyin Deng
Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA; Department of Anesthesiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, 410013, PR China
1 shared publication
Latest Publications
- Open Access
- 2 July 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
An automated, digital immunoassay on a microfluidic cartridge for on-demand cytokine profiling
Patients with critical illness often exhibit profound biological heterogeneity, complicating the identification of effective interventions. Resolving distinct molecular profiles to enable timely treatment decisions remains challenging, as integrating biomarker-guided care into routine monitoring is often hindered by fragmented, batch-based workflows. These manual operations decouple molecular data from the acute clinical timeline and are a barrier to reliable, real-time, near to patient, multi-center implementation. To address this gap, we developed an integrated microfluidic digital immunoassay system that achieves high analytical fidelity through a fully automated, simple workflow. The system utilizes a monolithic disposable cartridge to automate bead-based analyte capture, oil-phase partitioning, and signal amplification, eliminating the manual handling and emulsion steps that typically compromise digital assay robustness. The platform enables protein measurement within 45 minutes, achieving sub-picogram limit of detection ( < 0.13 pg/mL), a dynamic range spanning three orders of magnitude, and strong analytical reproducibility. We demonstrate the clinical utility of the system by profiling a validated panel of inflammatory biomarkers in plasma from critically ill pediatric patients, using low sample volumes. Results show strong agreement with gold-standard multiplex assays (R2 = 0.925-0.979). By providing a scalable framework for high-fidelity molecular profiling, this system supports the broader goal of accessible, multi-center biomarker validation and the practical implementation of precision medicine in critical care.
- 2 July 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1)
Open AccessAn automated, digital immunoassay on a microfluidic cartridge for on-demand cytokine profiling
Patients with critical illness often exhibit profound biological heterogeneity, complicating the identification of effective interventions. Resolving distinct molecular profiles to enable timely treatment decisions remains challenging, as integrating biomarker-guided care into routine monitoring is often hindered by fragmented, batch-based workflows. These manual operations decouple molecular data from the acute clinical timeline and are a barrier to reliable, real-time, near to patient, multi-center implementation. To address this gap, we developed an integrated microfluidic digital immunoassay system that achieves high analytical fidelity through a fully automated, simple workflow. The system utilizes a monolithic disposable cartridge to automate bead-based analyte capture, oil-phase partitioning, and signal amplification, eliminating the manual handling and emulsion steps that typically compromise digital assay robustness. The platform enables protein measurement within 45 minutes, achieving sub-picogram limit of detection ( < 0.13 pg/mL), a dynamic range spanning three orders of magnitude, and strong analytical reproducibility. We demonstrate the clinical utility of the system by profiling a validated panel of inflammatory biomarkers in plasma from critically ill pediatric patients, using low sample volumes. Results show strong agreement with gold-standard multiplex assays (R2 = 0.925-0.979). By providing a scalable framework for high-fidelity molecular profiling, this system supports the broader goal of accessible, multi-center biomarker validation and the practical implementation of precision medicine in critical care.
- 24 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117820
High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA
- 24 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117820
High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA