Huimeng Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huimeng Zhao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jinxiu Cheng
College of Bioengineering, Chongqing University, Chongqing 400030, China
2 shared publications - Zhong Ji
College of Bioengineering, Chongqing University, Chongqing 400030, China
2 shared publications - Hui Hui
College of Bioengineering, Chongqing University, Chongqing 400030, China
1 shared publication - Jun Wang
College of Bioengineering, Chongqing University, Chongqing 400030, China
1 shared publication - Pengfei Xie
Key Laboratory of Biorheological Science and Technology of Ministry of Education, College of Bioengineering, Chongqing University, Chongqing 400044, China
1 shared publication
Latest Publications
- Open Access
MDT-HMTL: A Multidimensional Temporal Hierarchical Multi-Task Learning Framework for Myocardial Infarction Detection and State Classification Using PPG Signals
Continuous assessment of myocardial infarction (MI) using photoplethysmography (PPG) signals has potential for out-of-hospital cardiovascular monitoring, yet conventional single-channel and short-window approaches have limitations in capturing complex hemodynamic variations and dynamic disease-state transitions. To address these limitations, we propose MDT-HMTL, a Multidimensional Temporal Hierarchical Multi-Task Learning framework tailored for simultaneous MI detection and disease-state classification. By integrating multi-channel physiological representations with hierarchical temporal modeling, MDT-HMTL captures local morphological characteristics and longer-range temporal dependencies within a unified multi-task architecture. Evaluation on the MIMIC-III clinical database achieved an average area under the ROC curve (AUC) of 0.908 and an overall accuracy of 86.4%. Furthermore, ablation studies demonstrated the contributions of multi-dimensional representation learning and hierarchical temporal modeling to the overall performance. The proposed framework demonstrates the feasibility of PPG-based MI detection and longitudinal disease-state assessment, highlighting its potential for future non-invasive and wearable-compatible cardiovascular monitoring.
Open AccessMDT-HMTL: A Multidimensional Temporal Hierarchical Multi-Task Learning Framework for Myocardial Infarction Detection and State Classification Using PPG Signals
Continuous assessment of myocardial infarction (MI) using photoplethysmography (PPG) signals has potential for out-of-hospital cardiovascular monitoring, yet conventional single-channel and short-window approaches have limitations in capturing complex hemodynamic variations and dynamic disease-state transitions. To address these limitations, we propose MDT-HMTL, a Multidimensional Temporal Hierarchical Multi-Task Learning framework tailored for simultaneous MI detection and disease-state classification. By integrating multi-channel physiological representations with hierarchical temporal modeling, MDT-HMTL captures local morphological characteristics and longer-range temporal dependencies within a unified multi-task architecture. Evaluation on the MIMIC-III clinical database achieved an average area under the ROC curve (AUC) of 0.908 and an overall accuracy of 86.4%. Furthermore, ablation studies demonstrated the contributions of multi-dimensional representation learning and hierarchical temporal modeling to the overall performance. The proposed framework demonstrates the feasibility of PPG-based MI detection and longitudinal disease-state assessment, highlighting its potential for future non-invasive and wearable-compatible cardiovascular monitoring.
- Open Access
Differential Absorbance and PPG-Based Non-Invasive Blood Glucose Measurement Using Spatiotemporal Multimodal Fused LSTM Model
Blood glucose monitoring is crucial for the daily management of diabetic patients. In this study, we developed a differential absorbance and photoplethysmography (PPG)-based non-invasive blood glucose measurement system (NIBGMS) using visible–near-infrared (Vis-NIR) light. Three light-emitting diodes (LEDs) (625 nm, 850 nm, and 940 nm) and three photodetectors (PDs) with different source–detector separation distances were used to detect the differential absorbance of tissues at different depths and PPG signals of the index finger. A spatiotemporal multimodal fused long short-term memory (STMF-LSTM) model was developed to improve the prediction accuracy of blood glucose levels by multimodal fusion of optical spatial information (differential absorbance and PPG signals) and glucose temporal information. The validity of the NIBGMS was preliminarily verified using multilayer perceptron (MLP), support vector regression (SVR), random forest regression (RFR), and extreme gradient boosting (XG Boost) models on datasets collected from 15 non-diabetic subjects and 3 type-2 diabetic subjects, with a total of 805 samples. Additionally, a continuous dataset consisting 272 samples from four non-diabetic subjects was used to validate the developed STMF-LSTM model. The results demonstrate that the STMF-LSTM model indicated improved prediction performance with a root mean square error (RMSE) of 0.811 mmol/L and a percentage of 100% for Parkes error grid analysis (EGA) Zone A and B in 8-fold cross validation. Therefore, the developed NIBGMS and STMF-LSTM model show potential in practical non-invasive blood glucose monitoring.
Open AccessDifferential Absorbance and PPG-Based Non-Invasive Blood Glucose Measurement Using Spatiotemporal Multimodal Fused LSTM Model
Blood glucose monitoring is crucial for the daily management of diabetic patients. In this study, we developed a differential absorbance and photoplethysmography (PPG)-based non-invasive blood glucose measurement system (NIBGMS) using visible–near-infrared (Vis-NIR) light. Three light-emitting diodes (LEDs) (625 nm, 850 nm, and 940 nm) and three photodetectors (PDs) with different source–detector separation distances were used to detect the differential absorbance of tissues at different depths and PPG signals of the index finger. A spatiotemporal multimodal fused long short-term memory (STMF-LSTM) model was developed to improve the prediction accuracy of blood glucose levels by multimodal fusion of optical spatial information (differential absorbance and PPG signals) and glucose temporal information. The validity of the NIBGMS was preliminarily verified using multilayer perceptron (MLP), support vector regression (SVR), random forest regression (RFR), and extreme gradient boosting (XG Boost) models on datasets collected from 15 non-diabetic subjects and 3 type-2 diabetic subjects, with a total of 805 samples. Additionally, a continuous dataset consisting 272 samples from four non-diabetic subjects was used to validate the developed STMF-LSTM model. The results demonstrate that the STMF-LSTM model indicated improved prediction performance with a root mean square error (RMSE) of 0.811 mmol/L and a percentage of 100% for Parkes error grid analysis (EGA) Zone A and B in 8-fold cross validation. Therefore, the developed NIBGMS and STMF-LSTM model show potential in practical non-invasive blood glucose monitoring.