Zhong Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhong Ji has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Haiyan Wu
College of Bioengineering, Chongqing University, Chongqing 400044, China
2 shared publications - Huimeng Zhao
College of Bioengineering, Chongqing University, Chongqing 400030, China
2 shared publications - Jinxiu Cheng
College of Bioengineering, Chongqing University, Chongqing 400030, China
2 shared publications Juan Dai
College of biological Engineering, Chongqing University, Chongqing 400044, P.R.China
2 shared publicationsYubao Du
College of biological Engineering, Chongqing University, Chongqing 400044, P.R.China
2 shared publicationsChangjun Hou
Key Laboratory for Biorheological Science and Technology (Chongqing University), Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, PR China; Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing, 400044, PR China
1 shared publication
Latest Publications
- Open Access
MDT-HMTL: A Multidimensional Temporal Hierarchical Multi-Task Learning Framework for Myocardial Infarction Detection and State Classification Using PPG Signals
Continuous assessment of myocardial infarction (MI) using photoplethysmography (PPG) signals has potential for out-of-hospital cardiovascular monitoring, yet conventional single-channel and short-window approaches have limitations in capturing complex hemodynamic variations and dynamic disease-state transitions. To address these limitations, we propose MDT-HMTL, a Multidimensional Temporal Hierarchical Multi-Task Learning framework tailored for simultaneous MI detection and disease-state classification. By integrating multi-channel physiological representations with hierarchical temporal modeling, MDT-HMTL captures local morphological characteristics and longer-range temporal dependencies within a unified multi-task architecture. Evaluation on the MIMIC-III clinical database achieved an average area under the ROC curve (AUC) of 0.908 and an overall accuracy of 86.4%. Furthermore, ablation studies demonstrated the contributions of multi-dimensional representation learning and hierarchical temporal modeling to the overall performance. The proposed framework demonstrates the feasibility of PPG-based MI detection and longitudinal disease-state assessment, highlighting its potential for future non-invasive and wearable-compatible cardiovascular monitoring.
Open AccessMDT-HMTL: A Multidimensional Temporal Hierarchical Multi-Task Learning Framework for Myocardial Infarction Detection and State Classification Using PPG Signals
Continuous assessment of myocardial infarction (MI) using photoplethysmography (PPG) signals has potential for out-of-hospital cardiovascular monitoring, yet conventional single-channel and short-window approaches have limitations in capturing complex hemodynamic variations and dynamic disease-state transitions. To address these limitations, we propose MDT-HMTL, a Multidimensional Temporal Hierarchical Multi-Task Learning framework tailored for simultaneous MI detection and disease-state classification. By integrating multi-channel physiological representations with hierarchical temporal modeling, MDT-HMTL captures local morphological characteristics and longer-range temporal dependencies within a unified multi-task architecture. Evaluation on the MIMIC-III clinical database achieved an average area under the ROC curve (AUC) of 0.908 and an overall accuracy of 86.4%. Furthermore, ablation studies demonstrated the contributions of multi-dimensional representation learning and hierarchical temporal modeling to the overall performance. The proposed framework demonstrates the feasibility of PPG-based MI detection and longitudinal disease-state assessment, highlighting its potential for future non-invasive and wearable-compatible cardiovascular monitoring.
- Open Access
Differential Absorbance and PPG-Based Non-Invasive Blood Glucose Measurement Using Spatiotemporal Multimodal Fused LSTM Model
Blood glucose monitoring is crucial for the daily management of diabetic patients. In this study, we developed a differential absorbance and photoplethysmography (PPG)-based non-invasive blood glucose measurement system (NIBGMS) using visible–near-infrared (Vis-NIR) light. Three light-emitting diodes (LEDs) (625 nm, 850 nm, and 940 nm) and three photodetectors (PDs) with different source–detector separation distances were used to detect the differential absorbance of tissues at different depths and PPG signals of the index finger. A spatiotemporal multimodal fused long short-term memory (STMF-LSTM) model was developed to improve the prediction accuracy of blood glucose levels by multimodal fusion of optical spatial information (differential absorbance and PPG signals) and glucose temporal information. The validity of the NIBGMS was preliminarily verified using multilayer perceptron (MLP), support vector regression (SVR), random forest regression (RFR), and extreme gradient boosting (XG Boost) models on datasets collected from 15 non-diabetic subjects and 3 type-2 diabetic subjects, with a total of 805 samples. Additionally, a continuous dataset consisting 272 samples from four non-diabetic subjects was used to validate the developed STMF-LSTM model. The results demonstrate that the STMF-LSTM model indicated improved prediction performance with a root mean square error (RMSE) of 0.811 mmol/L and a percentage of 100% for Parkes error grid analysis (EGA) Zone A and B in 8-fold cross validation. Therefore, the developed NIBGMS and STMF-LSTM model show potential in practical non-invasive blood glucose monitoring.
Open AccessDifferential Absorbance and PPG-Based Non-Invasive Blood Glucose Measurement Using Spatiotemporal Multimodal Fused LSTM Model
Blood glucose monitoring is crucial for the daily management of diabetic patients. In this study, we developed a differential absorbance and photoplethysmography (PPG)-based non-invasive blood glucose measurement system (NIBGMS) using visible–near-infrared (Vis-NIR) light. Three light-emitting diodes (LEDs) (625 nm, 850 nm, and 940 nm) and three photodetectors (PDs) with different source–detector separation distances were used to detect the differential absorbance of tissues at different depths and PPG signals of the index finger. A spatiotemporal multimodal fused long short-term memory (STMF-LSTM) model was developed to improve the prediction accuracy of blood glucose levels by multimodal fusion of optical spatial information (differential absorbance and PPG signals) and glucose temporal information. The validity of the NIBGMS was preliminarily verified using multilayer perceptron (MLP), support vector regression (SVR), random forest regression (RFR), and extreme gradient boosting (XG Boost) models on datasets collected from 15 non-diabetic subjects and 3 type-2 diabetic subjects, with a total of 805 samples. Additionally, a continuous dataset consisting 272 samples from four non-diabetic subjects was used to validate the developed STMF-LSTM model. The results demonstrate that the STMF-LSTM model indicated improved prediction performance with a root mean square error (RMSE) of 0.811 mmol/L and a percentage of 100% for Parkes error grid analysis (EGA) Zone A and B in 8-fold cross validation. Therefore, the developed NIBGMS and STMF-LSTM model show potential in practical non-invasive blood glucose monitoring.
- 19 August 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48  (4) , 1715-1728
A lightGBM-based method for the signal quality assessment of wrist photoplethysmography
In the application of wrist-based Photoplethysmography (PPG) devices for health monitoring, assessing the quality of PPG signals is essential for accurately monitoring cardiovascular parameters. However, the wrist-based PPG signal is susceptible to motion and light interference in practical applications. A machine learning-based signal quality assessment algorithm for wrist PPG signals was proposed to improve the accuracy and reliability of the monitoring data. The algorithm’s performance was evaluated on two datasets: the publicly available Wearable and Clinical Signals (WCS) dataset, containing 3,038 wrist-based PPG segments collected from 18 volunteers using an Empatica E4 device; our LAB dataset, comprising 2,426 wrist-based PPG segments acquired from 12 volunteers under varied interference conditions via a custom-developed wearable watch system. Data pre-processing encompassed denoising and normalization, followed by the extraction of 11 mathematical statistical features in time and frequency domains based on pulse wave morphology and 2 features based on template matching (Euclidean Distance and Correlation Coefficient). The classifier, constructed using the LightGBM algorithm, achieved high performance under rigorous leave-one-subject-out cross-validation (LOSO-CV) on the WCS dataset (accuracy = 92.6%, precision = 96.6%, recall = 89.8%, F1-score = 91.4%, AUC = 0.925) and the LAB dataset (accuracy = 96.1%, precision = 98.1%, recall = 95.2%, F1-score = 96.6%, AUC = 0.941). The results show that the machine learning algorithm for wrist-based PPG signal quality assessment, combining the mathematical statistical features in time and frequency domains and the template matching features, can effectively enhance the performance of signal quality assessment, and provides a powerful tool for improving the accuracy of wearable devices in cardiovascular health monitoring.
- 19 August 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48  (4) , 1715-1728
A lightGBM-based method for the signal quality assessment of wrist photoplethysmography
In the application of wrist-based Photoplethysmography (PPG) devices for health monitoring, assessing the quality of PPG signals is essential for accurately monitoring cardiovascular parameters. However, the wrist-based PPG signal is susceptible to motion and light interference in practical applications. A machine learning-based signal quality assessment algorithm for wrist PPG signals was proposed to improve the accuracy and reliability of the monitoring data. The algorithm’s performance was evaluated on two datasets: the publicly available Wearable and Clinical Signals (WCS) dataset, containing 3,038 wrist-based PPG segments collected from 18 volunteers using an Empatica E4 device; our LAB dataset, comprising 2,426 wrist-based PPG segments acquired from 12 volunteers under varied interference conditions via a custom-developed wearable watch system. Data pre-processing encompassed denoising and normalization, followed by the extraction of 11 mathematical statistical features in time and frequency domains based on pulse wave morphology and 2 features based on template matching (Euclidean Distance and Correlation Coefficient). The classifier, constructed using the LightGBM algorithm, achieved high performance under rigorous leave-one-subject-out cross-validation (LOSO-CV) on the WCS dataset (accuracy = 92.6%, precision = 96.6%, recall = 89.8%, F1-score = 91.4%, AUC = 0.925) and the LAB dataset (accuracy = 96.1%, precision = 98.1%, recall = 95.2%, F1-score = 96.6%, AUC = 0.941). The results show that the machine learning algorithm for wrist-based PPG signal quality assessment, combining the mathematical statistical features in time and frequency domains and the template matching features, can effectively enhance the performance of signal quality assessment, and provides a powerful tool for improving the accuracy of wearable devices in cardiovascular health monitoring.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-13
A Wireless Portable System With Few Electrodes Using Thoracic Electrical Signals for Long-Term and Real-Time Hemodynamic Monitoring
Continuous, long-term hemodynamic monitoring is crucial for enhancing the prevention and diagnosis of cardiovascular diseases (CVDs). This study introduces a system that extracts impedance cardiography (ICG), electrocardiography (ECG), and respiratory (RESP) signals from thoracic electrical signals using only four electrodes. A wireless, portable hemodynamic monitoring system has been developed, capable of acquiring multimodal physiological signals, including ICG, ECG, and photoplethysmography (PPG), among others. A signal processing approach was developed, combining the timefrequency characteristics and temporal correlations of the signals. This method includes signal denoising and locating characteristic points, enabling the real-time calculation of hemodynamic parameters such as cardiac output (CO). Furthermore, an artificial neural network is constructed based on various features extracted from the multimodal physiological signals to estimate blood pressure (BP). The device measures $85\times 48\times 18$ mm, weighs 76 g, and consumes 260 mW of power. It can operate continuously for at least 24 h. When compared to a commercial bedside hemodynamic monitoring device, the consistency of the key measured hemodynamic parameters is relatively high. The system shows promising applications in diagnosing CVDs and managing chronic cardiovascular conditions.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74  (00189456) , 1-13
A Wireless Portable System With Few Electrodes Using Thoracic Electrical Signals for Long-Term and Real-Time Hemodynamic Monitoring
Continuous, long-term hemodynamic monitoring is crucial for enhancing the prevention and diagnosis of cardiovascular diseases (CVDs). This study introduces a system that extracts impedance cardiography (ICG), electrocardiography (ECG), and respiratory (RESP) signals from thoracic electrical signals using only four electrodes. A wireless, portable hemodynamic monitoring system has been developed, capable of acquiring multimodal physiological signals, including ICG, ECG, and photoplethysmography (PPG), among others. A signal processing approach was developed, combining the timefrequency characteristics and temporal correlations of the signals. This method includes signal denoising and locating characteristic points, enabling the real-time calculation of hemodynamic parameters such as cardiac output (CO). Furthermore, an artificial neural network is constructed based on various features extracted from the multimodal physiological signals to estimate blood pressure (BP). The device measures $85\times 48\times 18$ mm, weighs 76 g, and consumes 260 mW of power. It can operate continuously for at least 24 h. When compared to a commercial bedside hemodynamic monitoring device, the consistency of the key measured hemodynamic parameters is relatively high. The system shows promising applications in diagnosing CVDs and managing chronic cardiovascular conditions.
- 8 August 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47  (4) , 1547-1556
ICG signal denoising based on ICEEMDAN and PSO-VMD methods
Impedance cardiography (ICG) plays a crucial role in clinically evaluating cardiac systolic and diastolic functions, along with various other cardiac parameters. However, its accuracy heavily depends on precisely identifying feature points reflecting cardiac function. Moreover, traditional signal processing techniques used to mitigate random noise and breathing artifacts may inadvertently distort the amplitude and temporal characteristics of ICG signals. To address this issue, this study investigates a noise and artifact elimination method based on Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) and Particle Swarm Optimization-based Variational Mode Decomposition Algorithm (PSO-VMD). The goal is to preserve the amplitude and temporal features of ICG signals to ensure accurate feature point extraction and computation of associated cardiac parameters. Comparative analysis with signal processing methods employing various wavelet families and Ensemble Empirical Mode Decomposition (EEMD) in ICG signal processing applications reveals that the proposed method achieves superior signal-to-noise ratio (SNR) and lower root-mean-square error (RMSE), while demonstrating enhanced correlation and waveform consistency with the original signal.
- 8 August 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47  (4) , 1547-1556
ICG signal denoising based on ICEEMDAN and PSO-VMD methods
Impedance cardiography (ICG) plays a crucial role in clinically evaluating cardiac systolic and diastolic functions, along with various other cardiac parameters. However, its accuracy heavily depends on precisely identifying feature points reflecting cardiac function. Moreover, traditional signal processing techniques used to mitigate random noise and breathing artifacts may inadvertently distort the amplitude and temporal characteristics of ICG signals. To address this issue, this study investigates a noise and artifact elimination method based on Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise (ICEEMDAN) and Particle Swarm Optimization-based Variational Mode Decomposition Algorithm (PSO-VMD). The goal is to preserve the amplitude and temporal features of ICG signals to ensure accurate feature point extraction and computation of associated cardiac parameters. Comparative analysis with signal processing methods employing various wavelet families and Ensemble Empirical Mode Decomposition (EEMD) in ICG signal processing applications reveals that the proposed method achieves superior signal-to-noise ratio (SNR) and lower root-mean-square error (RMSE), while demonstrating enhanced correlation and waveform consistency with the original signal.
- Open Access
- 23 July 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8  (3) , 031501
A review: Blood pressure monitoring based on PPG and circadian rhythm
The demand for ambulatory blood pressure monitoring (ABPM) is increasing due to the global rise in cardiovascular disease patients. However, conventional ABPM methods are discontinuous and can disrupt daily activities and sleep patterns. Photoplethysmography (PPG) is gaining attention from researchers due to its simplicity, portability, affordability, and ease of signal acquisition. This paper critically examines the advancements achieved in the technology of PPG-guided noninvasive blood pressure (BP) monitoring and explores future opportunities. We have performed a literature search using the Web of Science and PubMed search engines, from January 2018 to October 2023, for PPG signal quality assessment (SQA), cuffless BP estimation using single PPG, and associations between circadian rhythm and BP. Based on this foundation, we first examine the impact of PPG signal quality on blood pressure estimation results while focusing on methods for assessing PPG signal quality. Subsequently, the methods documented for estimating cuff-free BP from PPG signals are summarized. Furthermore, the study examines how individual differences affect the accuracy of BP estimation, incorporating the factors that influence arterial blood pressure (ABP) and elucidating the impact of circadian rhythm on blood pressure. Finally, there will be a summary of the study's findings and suggestions for future research directions.
- 23 July 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8  (3) , 031501
Open AccessA review: Blood pressure monitoring based on PPG and circadian rhythm
The demand for ambulatory blood pressure monitoring (ABPM) is increasing due to the global rise in cardiovascular disease patients. However, conventional ABPM methods are discontinuous and can disrupt daily activities and sleep patterns. Photoplethysmography (PPG) is gaining attention from researchers due to its simplicity, portability, affordability, and ease of signal acquisition. This paper critically examines the advancements achieved in the technology of PPG-guided noninvasive blood pressure (BP) monitoring and explores future opportunities. We have performed a literature search using the Web of Science and PubMed search engines, from January 2018 to October 2023, for PPG signal quality assessment (SQA), cuffless BP estimation using single PPG, and associations between circadian rhythm and BP. Based on this foundation, we first examine the impact of PPG signal quality on blood pressure estimation results while focusing on methods for assessing PPG signal quality. Subsequently, the methods documented for estimating cuff-free BP from PPG signals are summarized. Furthermore, the study examines how individual differences affect the accuracy of BP estimation, incorporating the factors that influence arterial blood pressure (ABP) and elucidating the impact of circadian rhythm on blood pressure. Finally, there will be a summary of the study's findings and suggestions for future research directions.
- Open Access
Automatic Classification Method of Arrhythmias Based on 12-Lead Electrocardiogram
Cardiovascular disease is one of the main causes of death worldwide. Arrhythmias are an important group of cardiovascular diseases. The standard 12-lead electrocardiogram signals are an important tool for diagnosing arrhythmias. Although 12-lead electrocardiogram signals provide more comprehensive arrhythmia information than single-lead electrocardiogram signals, it is difficult to effectively fuse information between different leads. In addition, most of the current researches working on automatic diagnosis of cardiac arrhythmias are based on modeling and analysis of single-mode features extracted from one-dimensional electrocardiogram sequences, ignoring the frequency domain features of electrocardiogram signals. Therefore, developing an automatic arrhythmia detection algorithm based on 12-lead electrocardiogram with high accuracy and strong generalization ability is still challenging. In this paper, a multimodal feature fusion model based on the mechanism is developed. This model utilizes a dual channel deep neural network to extract different dimensional features from one-dimensional and two-dimensional electrocardiogram time–frequency maps, and combines attention mechanism to effectively fuse the important features of 12-lead, thereby obtaining richer arrhythmia information and ultimately achieving accurate classification of nine types of arrhythmia signals. This study used electrocardiogram signals from a mixed dataset to train, validate, and evaluate the model, with an average of score and average accuracy reached 0.85 and 0.97, respectively. Experimental results show that our algorithm has stable and reliable performance, so it is expected to have good practical application potential.Open AccessAutomatic Classification Method of Arrhythmias Based on 12-Lead Electrocardiogram
Cardiovascular disease is one of the main causes of death worldwide. Arrhythmias are an important group of cardiovascular diseases. The standard 12-lead electrocardiogram signals are an important tool for diagnosing arrhythmias. Although 12-lead electrocardiogram signals provide more comprehensive arrhythmia information than single-lead electrocardiogram signals, it is difficult to effectively fuse information between different leads. In addition, most of the current researches working on automatic diagnosis of cardiac arrhythmias are based on modeling and analysis of single-mode features extracted from one-dimensional electrocardiogram sequences, ignoring the frequency domain features of electrocardiogram signals. Therefore, developing an automatic arrhythmia detection algorithm based on 12-lead electrocardiogram with high accuracy and strong generalization ability is still challenging. In this paper, a multimodal feature fusion model based on the mechanism is developed. This model utilizes a dual channel deep neural network to extract different dimensional features from one-dimensional and two-dimensional electrocardiogram time–frequency maps, and combines attention mechanism to effectively fuse the important features of 12-lead, thereby obtaining richer arrhythmia information and ultimately achieving accurate classification of nine types of arrhythmia signals. This study used electrocardiogram signals from a mixed dataset to train, validate, and evaluate the model, with an average of score and average accuracy reached 0.85 and 0.97, respectively. Experimental results show that our algorithm has stable and reliable performance, so it is expected to have good practical application potential. - Open Access
Memorizing Complementation Network for Few-Shot Class-Incremental Learning
Few-shot Class-Incremental Learning (FSCIL) aims at learning new concepts continually with only a few samples, which is prone to suffer the catastrophic forgetting and overfitting problems. The inaccessibility of old classes and the scarcity of the novel samples make it formidable to realize the trade-off between retaining old knowledge and learning novel concepts. Inspired by that different models memorize different knowledge when learning novel concepts, we propose a Memorizing Complementation Network (MCNet) to ensemble multiple models that complements the different memorized knowledge with each other in novel tasks. Additionally, to update the model with few novel samples, we develop a Prototype Smoothing Hard-mining Triplet (PSHT) loss to push the novel samples away from not only each other in current task but also the old distribution. Extensive experiments on three benchmark datasets, e.g., CIFAR100, miniImageNet and CUB200, have demonstrated the superiority of our proposed method.
Open AccessMemorizing Complementation Network for Few-Shot Class-Incremental Learning
Few-shot Class-Incremental Learning (FSCIL) aims at learning new concepts continually with only a few samples, which is prone to suffer the catastrophic forgetting and overfitting problems. The inaccessibility of old classes and the scarcity of the novel samples make it formidable to realize the trade-off between retaining old knowledge and learning novel concepts. Inspired by that different models memorize different knowledge when learning novel concepts, we propose a Memorizing Complementation Network (MCNet) to ensemble multiple models that complements the different memorized knowledge with each other in novel tasks. Additionally, to update the model with few novel samples, we develop a Prototype Smoothing Hard-mining Triplet (PSHT) loss to push the novel samples away from not only each other in current task but also the old distribution. Extensive experiments on three benchmark datasets, e.g., CIFAR100, miniImageNet and CUB200, have demonstrated the superiority of our proposed method.
- Open Access
- 26 August 2021
- Published by MDPI AG in Healthcare
- Vol. 9  (9) , 1104
A Review of Monitoring Methods for Cerebral Blood Oxygen Saturation
In recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used clinical methods for cerebral blood oxygen saturation monitoring from different aspects: working principles, relevant parameters, current situations of research, commonly used equipment, and relative advantages of different methods. Furthermore, through comprehensive comparisons of the methods, we find that near-infrared spectroscopy (NIRS) technology has significant potentials and broad applications prospects in terms of cerebral oxygen saturation monitoring. Despite the current NIRS technology, the only bedside non-invasive cerebral oxygen saturation monitoring technology, still has many defects, it is more in line with the future development trend in the field of medical and health, and will become the main method gradually.
- 26 August 2021
- Published by MDPI AG in Healthcare
- Vol. 9  (9) , 1104
Open AccessA Review of Monitoring Methods for Cerebral Blood Oxygen Saturation
In recent years, cerebral blood oxygen saturation has become a key indicator during the perioperative period. Cerebral blood oxygen saturation monitoring is conducive to the early diagnosis and treatment of cerebral ischemia and hypoxia. The present study discusses the three most extensively used clinical methods for cerebral blood oxygen saturation monitoring from different aspects: working principles, relevant parameters, current situations of research, commonly used equipment, and relative advantages of different methods. Furthermore, through comprehensive comparisons of the methods, we find that near-infrared spectroscopy (NIRS) technology has significant potentials and broad applications prospects in terms of cerebral oxygen saturation monitoring. Despite the current NIRS technology, the only bedside non-invasive cerebral oxygen saturation monitoring technology, still has many defects, it is more in line with the future development trend in the field of medical and health, and will become the main method gradually.