Jaewon Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaewon Hong has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Minsoo Chun
Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
2 shared publications - Chang Heon Choi
Department of Radiation Oncology Seoul National University Hospital Seoul Republic of Korea
1 shared publication - Do Hoon Oh
Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
1 shared publication - Gwangdeok Park
Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
1 shared publication - Hong-Gyun Wu
Department of Radiation Oncology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
1 shared publication - Hyejo Ryu
Department of Radiation Oncology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong, Korea
1 shared publication
Latest Publications
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 129-138
Commissioning Experience of the Integral Quality Monitor System on an Elekta Versa HD Linear Accelerator
Gwangdeok Park, Hyojun Park, Do Hoon Oh, Hyejo Ryu, Jaewon Hong, Yoohyeon Kim, Lee Yoo, Su Hyeon Lee, Sanghoon Back, Minsoo Chun. Progress in Medical Physics 2025;36:129-38. https://doi.org/10.14316/pmp.2025.36.4.129
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 129-138
Open AccessCommissioning Experience of the Integral Quality Monitor System on an Elekta Versa HD Linear Accelerator
Gwangdeok Park, Hyojun Park, Do Hoon Oh, Hyejo Ryu, Jaewon Hong, Yoohyeon Kim, Lee Yoo, Su Hyeon Lee, Sanghoon Back, Minsoo Chun. Progress in Medical Physics 2025;36:129-38. https://doi.org/10.14316/pmp.2025.36.4.129
- Open Access
- 21 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70239
Development and evaluation of a comprehensive QA phantom for image quality and geometrical accuracy in CT and CBCT for radiotherapy
Purpose: This study presents MZ CUBE, a newly developed multipurpose phantom designed to assess both image quality and geometrical accuracy in image‐guided radiotherapy. Methods: The phantom is a 16 × 16 × 16 cm 3 cube made of acrylonitrile butadiene styrene and designed to evaluate HU constancy, HU uniformity, spatial integrity, spatial resolution, low contrast resolution, and geometrical accuracy. Two CT simulators (Big Bore RT and Discovery RT Gen3) and two cone‐beam CT (CBCT) systems (XVI and OBI) were used for verification alongside commercial phantoms (ACR 464 and CatPhan 504). Results: HU constancy differences were within 3 HU, and uniformity was within 1 HU for CT and 2 HU for CBCT, based on repeated MZ CUBE measurements. Spatial resolution with the MZ CUBE was 7 lp/cm (Big Bore RT), 8 lp/cm (Discovery RT Gen3), 7 lp/cm (XVI), and 8 lp/cm (OBI). The minimum discernible disk diameters were 7, 5, 6, and 6 mm, respectively. Geometrical accuracy was confirmed with translational offsets below 1 mm and rotational deviations below 0.2° for both CBCT systems. Conclusions: MZ CUBE enables comprehensive image quality and geometric accuracy evaluation in a single scan, offering an efficient and cost‐effective solution for radiotherapy QA.
- 21 August 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (9) , e70239
Open AccessDevelopment and evaluation of a comprehensive QA phantom for image quality and geometrical accuracy in CT and CBCT for radiotherapy
Purpose: This study presents MZ CUBE, a newly developed multipurpose phantom designed to assess both image quality and geometrical accuracy in image‐guided radiotherapy. Methods: The phantom is a 16 × 16 × 16 cm 3 cube made of acrylonitrile butadiene styrene and designed to evaluate HU constancy, HU uniformity, spatial integrity, spatial resolution, low contrast resolution, and geometrical accuracy. Two CT simulators (Big Bore RT and Discovery RT Gen3) and two cone‐beam CT (CBCT) systems (XVI and OBI) were used for verification alongside commercial phantoms (ACR 464 and CatPhan 504). Results: HU constancy differences were within 3 HU, and uniformity was within 1 HU for CT and 2 HU for CBCT, based on repeated MZ CUBE measurements. Spatial resolution with the MZ CUBE was 7 lp/cm (Big Bore RT), 8 lp/cm (Discovery RT Gen3), 7 lp/cm (XVI), and 8 lp/cm (OBI). The minimum discernible disk diameters were 7, 5, 6, and 6 mm, respectively. Geometrical accuracy was confirmed with translational offsets below 1 mm and rotational deviations below 0.2° for both CBCT systems. Conclusions: MZ CUBE enables comprehensive image quality and geometric accuracy evaluation in a single scan, offering an efficient and cost‐effective solution for radiotherapy QA.