    Evaluation of a multifunctional phantom for geometric, image quality, and dosimetric constancy of megavoltage electronic portal imaging devices

    by Inbum Lee, Minjae Choi, Yoonsuk Huh, Euntaek Yoon, Bo‐Wi Cheon, Na Hye Kwon, Young Jae Jang, Chang Heon Choi, Jung‐In Kim, So‐Yeon Park

    Background: Routine quality assurance (QA) of linear accelerators and electronic portal imaging devices (EPIDs) often requires separate devices and acquisition procedures for geometric, image‐quality, radiation‐field, multileaf collimator (MLC), and dosimetric checks. A multifunctional phantom could consolidate these assessments within a single QA workflow. Purpose: To evaluate the week‐to‐week reproducibility of measurements obtained with MZ Slab, a multifunctional megavoltage EPID phantom, on three linear accelerators with different EPID configurations. Methods: Measurements were performed weekly for four weeks on TrueBeam STx, Halcyon, and Harmony Pro. Each session comprised three acquisition sets with phantom removal and repositioning between sets. The phantom provided measurements of geometric accuracy, image quality, material‐response isotropy, and radiation‐field size, together with qualitative MLC light‐field checks. Weekly values were summarized as mean and within‐session standard deviation, and changes were assessed relative to week 1. Field sizes were compared with open‐field EPID images and IC Profiler measurements. Dose‐calibrated portal images acquired on TrueBeam were compared with the week 1 image using mean response change and gamma passing rates. Results: Central‐marker offset ranged from 0.24 to 0.78 mm across units, with a maximum change from week 1 of 0.29 mm. Marker‐distance deviations changed by no more than 0.03 mm. The maximum changes in mean relative contrast transfer function and low‐contrast contrast‐to‐noise ratio were 0.011 (2.6%) and 1.81 (5.0%), respectively, relative to the week 1 baseline. Uniformity deviation and normalized noise changed by up to 0.50 and 0.17 percentage points, and material‐specific normalized response by up to 0.014. Field sizes changed by up to 0.56 mm and agreed with open‐field EPID measurements within 0.3 mm. IC Profiler values were 0.2–0.9 mm larger than MZ Slab values. MLC leaf ends remained within the printed ± 1 mm tolerance. At week 4, mean portal‐image response had increased by 0.77%, with a gamma passing rate of 99.65% at 1%/1 mm. Conclusions: MZ Slab supported geometric, image‐quality, radiation‐field, qualitative MLC, and portal‐dosimetry assessments within a single‐phantom QA workflow. Measurements on three linacs characterized within‐session reproducibility and week‐to‐week consistency over four weeks. Longer observation and deliberate perturbation testing are required to establish action limits and fault‐detection sensitivity.

  • Open Access

    Development and evaluation of a comprehensive QA phantom for image quality and geometrical accuracy in CT and CBCT for radiotherapy

    by Minsoo Chun, Jaewon Hong, Jin Hwa Choi, Chang‐Heon Choi, Jung‐In Kim, Hong‐Gyun Wu, Minjae Choi, Na Young Jang, So‐Yeon Park

    Purpose: This study presents MZ CUBE, a newly developed multipurpose phantom designed to assess both image quality and geometrical accuracy in image‐guided radiotherapy. Methods: The phantom is a 16 × 16 × 16 cm 3 cube made of acrylonitrile butadiene styrene and designed to evaluate HU constancy, HU uniformity, spatial integrity, spatial resolution, low contrast resolution, and geometrical accuracy. Two CT simulators (Big Bore RT and Discovery RT Gen3) and two cone‐beam CT (CBCT) systems (XVI and OBI) were used for verification alongside commercial phantoms (ACR 464 and CatPhan 504). Results: HU constancy differences were within 3 HU, and uniformity was within 1 HU for CT and 2 HU for CBCT, based on repeated MZ CUBE measurements. Spatial resolution with the MZ CUBE was 7 lp/cm (Big Bore RT), 8 lp/cm (Discovery RT Gen3), 7 lp/cm (XVI), and 8 lp/cm (OBI). The minimum discernible disk diameters were 7, 5, 6, and 6 mm, respectively. Geometrical accuracy was confirmed with translational offsets below 1 mm and rotational deviations below 0.2° for both CBCT systems. Conclusions: MZ CUBE enables comprehensive image quality and geometric accuracy evaluation in a single scan, offering an efficient and cost‐effective solution for radiotherapy QA.