  • Shape-optimized model-based reconstruction algorithm for radiacoustic imaging

    by Prabodh Kumar Pandey, Omprakash Gottam, Kristina Bjegovic, Gilberto Gonzalez, Yong Chen, Liangzhong Xiang

    We present a shape-optimized model-based reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct an approximate dose-region boundary using a parametric level set–based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a much better-constrained one. We validate this methodology through computational studies and experiments using clinical x-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with a 3%–25% improvement in correlation coefficients across different imaging settings, with the more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.

  • Open Access

    Developing a Monte Carlo model for MEVION S250i with HYPERSCAN and Adaptive Aperture™ pencil beam scanning proton therapy system

    by Bing-Hao Chiang, Austin Bunker, Hosang Jin, Salahuddin Ahmad, Yong Chen

    Aim: As the number of proton therapy facilities has steadily increased, the need for the tool to provide precise dose simulation for complicated clinical and research scenarios also increase. In this study, the treatment head of Mevion HYPERSCAN pencil beam scanning (PBS) proton therapy system including energy modulation system (EMS) and Adaptive Aperture™ (AA) was modelled using TOPAS (TOolkit for PArticle Simulation) Monte Carlo (MC) code and was validated during commissioning process.Materials and methods: The proton beam characteristics including integral depth doses (IDDs) of pristine Bragg peak and in-air beam spot sizes were simulated and compared with measured beam data. The lateral profiles, with and without AA, were also verified against calculation from treatment planning system (TPS).Results: All beam characteristics for IDDs and in-air spot size agreed well within 1 mm and 10% separately. The full width at half maximum and penumbra of lateral dose profile also agree well within 2 mm.Finding: The TOPAS MC simulation of the MEVION HYPERSCAN PBS proton therapy system has been modelled and validated; it could be a viable tool for research and verification of the proton treatment in the future.