Luiz Carlos Simões Soares Junior
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luiz Carlos Simões Soares Junior has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- André Jackson Ramos Simões
Physics Institute, Federal University of Bahia, Barão de Jeremoabo Road, s/n, Salvador 40170-115, BA, Brazil
3 shared publications - André Luiz Andrade Simões
Environmental Engineering Department, Federal University of Bahia, Prof. Aristides Novis Road, n° 02, Federação, Salvador 40210-630, BA, Brazil
3 shared publications - Germano Pinto Guedes
Universidade Estadual de Feira de Santana, Feira de Santana
3 shared publications - Geydison Gonzaga Demetino
Center of Exact and Technological Sciences, Federal University of Recôncavo of Bahia, Cruz das Almas 44380-000, BA, Brazil
3 shared publications - Iuri Muniz Pepe
Physics Institute, Federal University of Bahia, Barão de Jeremoabo Road, s/n, Salvador 40170-115, BA, Brazil
3 shared publications - Juliane Grasiela de Carvalho Gomes
Physics Institute, Federal University of Bahia, Barão de Jeremoabo Road, s/n, Salvador 40170-115, BA, Brazil
3 shared publications
Latest Publications
- Open Access
Miniaturized Acoustic Sensing Platform for Spatial Mapping of Ultrasonic Fields in Small-Diameter Tube Bundles
Shell-and-tube heat exchangers often operate under harsh conditions that induce fouling, leading to loss of thermal efficiency, production downtime, and increased maintenance costs. Conventional cleaning procedures generally require scheduled or unscheduled shutdowns, with direct operational and financial impacts. In this context, ultrasonic cavitation has been investigated as a strategy for fouling prevention and equipment cleaning, with the potential to reduce cleaning downtime or support in-service mitigation strategies. This work presents the development of an acquisition platform based on a miniaturized, waterproof acoustic probe designed for operation inside 8 mm tubes under cavitating ultrasonic fields, with the goal of experimentally mapping the relative acoustic response amplitude and dominant frequency in U-tube heat exchangers. The system integrates a piezoelectric sensing element embedded in protective encapsulation, signal-conditioning electronics, and a high-sampling-rate acquisition module. Experiments were conducted in a reduced-scale exchanger comprising 90 access ports and measurement depths up to 775 mm, using 28 kHz ultrasonic transducers. The probe successfully captured both the spectral content and the spatial variation of the voltage-based acoustic response along the tube bundle, revealing position-dependent amplitude variations and dominant-frequency measurements concentrated around the imposed excitation frequency. The analysis supported the definition of a reduced set of representative sampling locations, decreasing acquisition time while preserving the main spatial trends relevant to the objectives of this study. The procedures established here provide an experimental basis for future studies on the application of ultrasound to fouling-mitigation strategies in industrial thermal systems.
Open AccessMiniaturized Acoustic Sensing Platform for Spatial Mapping of Ultrasonic Fields in Small-Diameter Tube Bundles
Shell-and-tube heat exchangers often operate under harsh conditions that induce fouling, leading to loss of thermal efficiency, production downtime, and increased maintenance costs. Conventional cleaning procedures generally require scheduled or unscheduled shutdowns, with direct operational and financial impacts. In this context, ultrasonic cavitation has been investigated as a strategy for fouling prevention and equipment cleaning, with the potential to reduce cleaning downtime or support in-service mitigation strategies. This work presents the development of an acquisition platform based on a miniaturized, waterproof acoustic probe designed for operation inside 8 mm tubes under cavitating ultrasonic fields, with the goal of experimentally mapping the relative acoustic response amplitude and dominant frequency in U-tube heat exchangers. The system integrates a piezoelectric sensing element embedded in protective encapsulation, signal-conditioning electronics, and a high-sampling-rate acquisition module. Experiments were conducted in a reduced-scale exchanger comprising 90 access ports and measurement depths up to 775 mm, using 28 kHz ultrasonic transducers. The probe successfully captured both the spectral content and the spatial variation of the voltage-based acoustic response along the tube bundle, revealing position-dependent amplitude variations and dominant-frequency measurements concentrated around the imposed excitation frequency. The analysis supported the definition of a reduced set of representative sampling locations, decreasing acquisition time while preserving the main spatial trends relevant to the objectives of this study. The procedures established here provide an experimental basis for future studies on the application of ultrasound to fouling-mitigation strategies in industrial thermal systems.
- Open Access
High-Speed Microprocessor-Based Optical Instrumentation for the Detection and Analysis of Hydrodynamic Cavitation Downstream of an Additively Manufactured Nozzle
This study presents the development and validation of a high-speed optical data acquisition system for detecting and characterizing hydrodynamic cavitation downstream of a triangular nozzle. The system integrates a PIN photodiode, a transimpedance amplifier, and a high-sampling-rate microcontroller. Its performance was first evaluated using controlled sinusoidal signals, and statistical stability was assessed as a function of the number of acquired samples. Experiments were subsequently conducted in a converging–diverging conduit under biphasic flow conditions, where mean irradiance, standard deviation, and frequency spectra were analyzed downstream of the nozzle. The optical signal distributions revealed transitions in flow behavior associated with cavitation development, which were quantified through statistical metrics and spectral features. The Strouhal number was estimated from dominant frequencies extracted from the spectra, exhibiting a non-monotonic dependence on the Reynolds number, consistent with changes in flow structure and turbulence intensity. Spectral analysis further indicated frequency bands associated with energy transfer across turbulent scales and bubble dynamics. Overall, the results demonstrate that the proposed optical system constitutes a viable and non-intrusive methodology for detecting and characterizing cavitation intensity in a way that complements other optical and acoustic methods.
Open AccessHigh-Speed Microprocessor-Based Optical Instrumentation for the Detection and Analysis of Hydrodynamic Cavitation Downstream of an Additively Manufactured Nozzle
This study presents the development and validation of a high-speed optical data acquisition system for detecting and characterizing hydrodynamic cavitation downstream of a triangular nozzle. The system integrates a PIN photodiode, a transimpedance amplifier, and a high-sampling-rate microcontroller. Its performance was first evaluated using controlled sinusoidal signals, and statistical stability was assessed as a function of the number of acquired samples. Experiments were subsequently conducted in a converging–diverging conduit under biphasic flow conditions, where mean irradiance, standard deviation, and frequency spectra were analyzed downstream of the nozzle. The optical signal distributions revealed transitions in flow behavior associated with cavitation development, which were quantified through statistical metrics and spectral features. The Strouhal number was estimated from dominant frequencies extracted from the spectra, exhibiting a non-monotonic dependence on the Reynolds number, consistent with changes in flow structure and turbulence intensity. Spectral analysis further indicated frequency bands associated with energy transfer across turbulent scales and bubble dynamics. Overall, the results demonstrate that the proposed optical system constitutes a viable and non-intrusive methodology for detecting and characterizing cavitation intensity in a way that complements other optical and acoustic methods.
- Open Access
Experimental and Numerical Analysis of Nozzle-Induced Cavitating Jets: Optical Instrumentation, Pressure Fluctuations and Anisotropic Turbulence Modeling
Cavitation has been widely explored to enhance physical and chemical processes across various applications. This study aimed to model the key characteristics of a cavitation jet, induced by a triangular-orifice nozzle, using both experimental and numerical methods. Optical instrumentation, a pressure transducer and the Reynolds-Averaged Navier–Stokes (RANS) equations were employed. Optical instrumentation and high-speed photography detected the two-phase flow generated by water vaporization, revealing a mean decay pattern. Irradiance fluctuations and photographic evidence provided results about the light transmission dynamics through cavitating jets. Pressure fluctuations exhibited similar growth and decay, supporting optical instrumentation as a viable method for assessing cavitation intensity. Experimental data showed a strong relationship between irradiance and flow rate (R2 = 0.998). This enabled the correlation of the standard deviation of instantaneous pressure measurements and normalized flow rate (R2 = 0.977). Furthermore, vapor volume fraction and normalized flow rate reached a correlation coefficient of 0.999. On the simulation side, the SSG-RSM turbulence mode showed better agreement with experimental data, with relative deviations ranging from 2.1% to 6.6%. The numerical results suggest that vapor jet length is related to vapor fraction through a power law, enabling the development of new equations. These results demonstrated that anisotropic turbulence modeling is essential to reproduce experimental observations compared to mean flow properties. Based on the agreement between the numerical model and the experimental data for mean flow quantities, a formulation is proposed to estimate the jet length originating from the nozzle, offering a predictive approach for cavitating jet behavior.
Open AccessExperimental and Numerical Analysis of Nozzle-Induced Cavitating Jets: Optical Instrumentation, Pressure Fluctuations and Anisotropic Turbulence Modeling
Cavitation has been widely explored to enhance physical and chemical processes across various applications. This study aimed to model the key characteristics of a cavitation jet, induced by a triangular-orifice nozzle, using both experimental and numerical methods. Optical instrumentation, a pressure transducer and the Reynolds-Averaged Navier–Stokes (RANS) equations were employed. Optical instrumentation and high-speed photography detected the two-phase flow generated by water vaporization, revealing a mean decay pattern. Irradiance fluctuations and photographic evidence provided results about the light transmission dynamics through cavitating jets. Pressure fluctuations exhibited similar growth and decay, supporting optical instrumentation as a viable method for assessing cavitation intensity. Experimental data showed a strong relationship between irradiance and flow rate (R2 = 0.998). This enabled the correlation of the standard deviation of instantaneous pressure measurements and normalized flow rate (R2 = 0.977). Furthermore, vapor volume fraction and normalized flow rate reached a correlation coefficient of 0.999. On the simulation side, the SSG-RSM turbulence mode showed better agreement with experimental data, with relative deviations ranging from 2.1% to 6.6%. The numerical results suggest that vapor jet length is related to vapor fraction through a power law, enabling the development of new equations. These results demonstrated that anisotropic turbulence modeling is essential to reproduce experimental observations compared to mean flow properties. Based on the agreement between the numerical model and the experimental data for mean flow quantities, a formulation is proposed to estimate the jet length originating from the nozzle, offering a predictive approach for cavitating jet behavior.