Sebastian Haberl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sebastian Haberl has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Antonio Solans Sanchez
CERN
4 shared publications - Lucian Fasselt
Deutsches Elektronen-Synchrotron DESY
4 shared publications C. Buttar
University of Glasgow, Glasgow, U.K.
3 shared publications- Dumitru Vlad Berlea
Deutsches Elektronen-Synchrotron DESY, Zeuthen, Germany
3 shared publications H. Pernegger
3 shared publications- Ignacio Asensi Tortajada
CERN, Geneva, Switzerland
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
TCAD optimization and validation of MAPS with internal low-gain amplification
- 1 October 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1094
Open AccessTCAD optimization and validation of MAPS with internal low-gain amplification
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , C08010
CASSIA: a CMOS active pixel sensor with internal gain and implementation of in-pixel front-end and readout
Future high-energy physics experiments require tracking detectors with improved timing and spatial resolution, combined with a low material budget. The CASSIA project addresses these requirements by developing a monolithic pixel detector with internal amplification, achieved through implementation of gain layers in a commercial 180 nm CMOS imaging process. The first prototype, CASSIA1, includes four 3×3-pixel matrices and 24 single-pixel structures with varying gain layer geometries and electrode spacings, which affect gain, noise and breakdown behaviour. CASSIA1 was characterised using TCT and source measurements, with temperature-dependent noise studies conducted in a controlled climate chamber. Measurements confirm operation in both LGAD and SPAD regimes, soft-breakdown behaviour allowing fine gain tuning, and low dark count rates suitable for high-SNR applications. The results of this characterisation campaign informed both the improved sensor design and the in-pixel front-end electronics for CASSIA2. The next-generation CASSIA2 chip, also submitted in 180 nm CMOS, will feature larger matrices with a fully scaled front-end, combining mixed digital and analogue readout. Its design will be presented, highlighting the challenges of integrating LGAD structures within CMOS circuitry. The design stages, from in-pixel circuit placement to top-level digital readout architecture, are discussed.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , C08010
Open AccessCASSIA: a CMOS active pixel sensor with internal gain and implementation of in-pixel front-end and readout
Future high-energy physics experiments require tracking detectors with improved timing and spatial resolution, combined with a low material budget. The CASSIA project addresses these requirements by developing a monolithic pixel detector with internal amplification, achieved through implementation of gain layers in a commercial 180 nm CMOS imaging process. The first prototype, CASSIA1, includes four 3×3-pixel matrices and 24 single-pixel structures with varying gain layer geometries and electrode spacings, which affect gain, noise and breakdown behaviour. CASSIA1 was characterised using TCT and source measurements, with temperature-dependent noise studies conducted in a controlled climate chamber. Measurements confirm operation in both LGAD and SPAD regimes, soft-breakdown behaviour allowing fine gain tuning, and low dark count rates suitable for high-SNR applications. The results of this characterisation campaign informed both the improved sensor design and the in-pixel front-end electronics for CASSIA2. The next-generation CASSIA2 chip, also submitted in 180 nm CMOS, will feature larger matrices with a fully scaled front-end, combining mixed digital and analogue readout. Its design will be presented, highlighting the challenges of integrating LGAD structures within CMOS circuitry. The design stages, from in-pixel circuit placement to top-level digital readout architecture, are discussed.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04001
Charge collection parameterization of MALTA2, a depleted monolithic active pixel sensor
A fast simulation method is presented for a depleted monolithic active pixel sensor, which uses a data driven parameterization of the charge collection and propagation. This approach provides an efficient alternative to TCAD simulations, particularly for sensors whose proprietary process details — such as doping profiles or implant geometries — are unavailable. Data was obtained with a MALTA2 sensor fabricated in a 180 nm CMOS imaging technology on 30 µm epitaxial silicon using the MALTA beam telescope at CERN SPS. The model reproduces the measured in-pixel efficiency with high accuracy and enables a realistic yet computationally lightweight analog pixel simulation. This method will be further employed in optimizing the digital sensor design for applications in high-rate particle tracking and high-granularity calorimetry.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04001
Open AccessCharge collection parameterization of MALTA2, a depleted monolithic active pixel sensor
A fast simulation method is presented for a depleted monolithic active pixel sensor, which uses a data driven parameterization of the charge collection and propagation. This approach provides an efficient alternative to TCAD simulations, particularly for sensors whose proprietary process details — such as doping profiles or implant geometries — are unavailable. Data was obtained with a MALTA2 sensor fabricated in a 180 nm CMOS imaging technology on 30 µm epitaxial silicon using the MALTA beam telescope at CERN SPS. The model reproduces the measured in-pixel efficiency with high accuracy and enables a realistic yet computationally lightweight analog pixel simulation. This method will be further employed in optimizing the digital sensor design for applications in high-rate particle tracking and high-granularity calorimetry.
- Open Access
- 11 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
- 11 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Open AccessCharge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
- Open Access
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09039
Timing characterization of MALTA and MALTA2 pixel detectors using Micro X-ray source
The MALTA monolithic active pixel detector is developed to address some of the challenges anticipated in future high-energy physics detectors. As part of its characterization, we conducted timing studies necessary to provide a figure of merit for this family of monolithic pixel detectors. MALTA has a metal layer in front-end electronics, and the conventional laser technique is not suitable for timing studies due to the reflection of the laser from the metallic surface. X-rays have been employed as a more effective alternative for penetration through these layers. The triggered X-ray set-up is designed to study timing measurements of monolithic detectors. The timing response of the X-ray set-up is characterized using an LGAD. The timing response of the MALTA and MALTA2 pixel detectors is studied, and the best response time of MALTA2 pixel detectors is measured at about 2.6 ns.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09039
Open AccessTiming characterization of MALTA and MALTA2 pixel detectors using Micro X-ray source
The MALTA monolithic active pixel detector is developed to address some of the challenges anticipated in future high-energy physics detectors. As part of its characterization, we conducted timing studies necessary to provide a figure of merit for this family of monolithic pixel detectors. MALTA has a metal layer in front-end electronics, and the conventional laser technique is not suitable for timing studies due to the reflection of the laser from the metallic surface. X-rays have been employed as a more effective alternative for penetration through these layers. The triggered X-ray set-up is designed to study timing measurements of monolithic detectors. The timing response of the X-ray set-up is characterized using an LGAD. The timing response of the MALTA and MALTA2 pixel detectors is studied, and the best response time of MALTA2 pixel detectors is measured at about 2.6 ns.