RTRicardo Teixeira

Ricardo Teixeira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ricardo Teixeira has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An AI-Based Solution for Denoising Fast-Acquisition [18F]FDG PET: Clinical Feasibility and Quantitative Assessment

    by Luísa C. Silva, Cláudia S. Constantino, Ricardo Teixeira, Joana C. Castanheira, Francisco P. M. Oliveira, Durval C. Costa

    Benefits in patient comfort, efficiency, and sustainability can come from reducing positron emission tomography (PET) scan’s acquisition duration. This study assesses the clinical adequacy of restoring fast-acquisition 18 F-fluorodeoxyglucose ([ 18 F]FDG) PET to its standard-of-care image quality through deep-learning-based (DL) methods. Fast and standard whole-body [ 18 F]FDG PET acquisitions of 117 oncological patients were included in the training and testing of three convolutional neural networks. The best-performing network during training was chosen for clinical evaluation on the test set ( N = 25). Visual assessment and lesion detectability of the fast acquisitions, of 20 and 30 seconds per axial field of view (s/AFOV), with and without DL-based denoising, and of the local standard of care, of 70 s/AFOV, were performed by three experienced nuclear medicine physicians. Quantification was conducted globally (voxel-wise), in healthy organs and the reported lesions. Optimised Gaussian and non-local means filters served as benchmarks. Visual assessment revealed 20 and 30 s/AFOV with DL-based denoising to have similar image quality to the standard of care. Average lesion-based sensitivity and positive predictive value were 74% and 72%, respectively, for 20 s/AFOV + DL and 72% and 80% for 30 s/AFOV + DL. DL-based denoising displayed the highest voxel-wise agreement with the standard-of-care ( p < 0.001). Liver and lungs in the DL-denoised images exhibited a higher signal-to-noise ratio than the standard of care. The median absolute maximum standardised uptake value deviation in the lesions was as low as 0.39 for 20 s/AFOV + DL and 0.30 for 30 s/AFOV + DL. The proposed DL-based method proved to be suitable for the restoration of fast-acquisition whole-body [ 18 F]FDG PET, having resulted in images similar to the standard-of-care acquisitions. DL-based denoising outperformed standard benchmark methods.

  • Open Access

    18F-FDG PET/CT in Patients with Vulvar and Vaginal Cancer: A Preliminary Study of 20 Cases

    by Patrícia Gouveia, Adriana Sá Pinto, Liliana Violante, Sara Nunes, Ricardo Teixeira, Almerinda Petiz, Luís Hugo Duarte

    Introduction: Despite the growing evidence supporting the use of 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography in cervical and ovarian malignant tumours, data on vulvar and vaginal cancer is sparse. Our aim was to assess the role of 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography in patients with vulvar and vaginal cancer. Material and Methods: A retrospective study was conducted on a cohort of 20 patients with biopsy-proven vulvar (n = 17) and vaginal (n = 3) cancer who performed 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography, between January 2013 and April 2018. We collected the clinical data of all patients, as well as the indication for 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography, its results, and the main lesion maximum standard uptake value (SUVmax). In addition, we correlated the results of 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography with other diagnostic modalities, namely histological findings, computed tomography and magnetic resonance imaging. Patients were divided into two groups, one with newly diagnosed disease and another with recurrent disease. Results: Six patients had newly diagnosed disease and 14 had recurrent disease. The main lesion was detected by 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography in five out of six patients with newly diagnosed disease and in all 14 patients with recurrent disease. Additional sites of 2-[F-18]-fluor-2-desoxi-D-glucose uptake were identified in inguinal and iliac lymph nodes and in distant lesions. Magnetic resonance imaging and computed tomography were performed in 12 cases. In four patients with recurrent disease, abnormalities (main lesion/ metastatic lymph nodes) identified by 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography were not detected as suspicious by computed tomography. Discussion: In our study, 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography identified abnormalities more often than conventional computed tomography scans in recurrent disease. In comparison with histology, 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography had a sensitivity of 95% and a positive predictive value of 100% in identifying the primary tumour and the recurrent main lesion. Little data is available regarding the usefulness of 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography in the management of vulvar and vaginal cancers. The existing evidence supports a high accuracy in detecting lymph node metastases and a change of 36.0% - 61.5% in patient management. Our findings reinforce the usefulness of this technique in vulvar and vaginal cancer. Limitations of our study include its retrospective nature and the rareness of both vulvar and vaginal cancer, which leads to a small sample size and few comparative imaging tests. Conclusion: In this preliminary study, 2-[F-18]-fluor-2-desoxi-D-glucose positron emission tomography/computed tomography demonstrated it can be a useful method in patients with vulvar and vaginal cancers, namely in defining the extent of disease and contributing to accurate staging and restaging.