Xing Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xing Lei has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ci Song
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications - Guanjun Zhang
Xi’an Jiaotong University
2 shared publications - Haibao Mu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications - Kaixuan Fan
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications - Xingyu Zou
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications - Ziqian Cheng
School of Electrical Engineering and the State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
2 shared publications
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Cable Defect Location and Evaulation Based on Stepped-Frequency Waveform Reflectometry and Assisted Digital Twin Technology
The travelling wave reflection method is widely used to detect cable defects in modern industrial systems due to its non-destructive nature and high efficiency. However, the overlapping echoes of the defect with short length will result in inaccurate defect evaluation. In view of this, this paper proposes a novel cable defect diagnosis method based on stepped-frequency waveform reflectometry (SFWR) and assisted digital twin technology. First, the frequency response functions (FRFs) of two typical defects: point-like defect and line-like defect are constructed, and the limitations of line loss compensation for evaluating the short line-like defect is analysed. Then, a distinction method based on polarity interval is proposed to determine whether defect echoes exhibit overlapping. Finally, the assisted digital twin technology is used to separate defect overlapping echoes, ensuring the accuracy of defect evaluation. Simulations and experiments show that the method proposed in this paper exhibits good performance in evaluating the line-like defect with short length.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Cable Defect Location and Evaulation Based on Stepped-Frequency Waveform Reflectometry and Assisted Digital Twin Technology
The travelling wave reflection method is widely used to detect cable defects in modern industrial systems due to its non-destructive nature and high efficiency. However, the overlapping echoes of the defect with short length will result in inaccurate defect evaluation. In view of this, this paper proposes a novel cable defect diagnosis method based on stepped-frequency waveform reflectometry (SFWR) and assisted digital twin technology. First, the frequency response functions (FRFs) of two typical defects: point-like defect and line-like defect are constructed, and the limitations of line loss compensation for evaluating the short line-like defect is analysed. Then, a distinction method based on polarity interval is proposed to determine whether defect echoes exhibit overlapping. Finally, the assisted digital twin technology is used to separate defect overlapping echoes, ensuring the accuracy of defect evaluation. Simulations and experiments show that the method proposed in this paper exhibits good performance in evaluating the line-like defect with short length.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noncontact Monitoring of Gate-Oxide Degradation in SiC MOSFETs Using Gate-Switching Oscillation
The online monitoring of SiC MOSFET gate-oxide degradation presents significant challenges in terms of safety and sensitivity due to the harsh electromagnetic environment and the subtle nature of aging symptoms. To address these challenges, this article proposes a novel non-contact monitoring method for detecting gate-oxide degradation in SiC MOSFETs by extracting the amplitude feature of the turn-on switching oscillation from the gate current. Theoretical analysis reveals that gate-oxide degradation in SiC MOSFETs results in an increase in turn-on time, which subsequently impacts the gate switching oscillation current through the high-frequency (HF) coupling effect of the Miller capacitance. A non-contact monitoring scheme is proposed, utilizing an HF oscillation current sensor and peak detection circuit. To validate the proposed method, an experimental study was conducted on a half-bridge converter equipped with 1.2 kV/30 A SiC MOSFETs. High electric field (HEF) accelerated aging tests were performed under a gate-source voltage condition of Vgs=33 V to investigate the characteristics of gate-oxide degradation. The experimental results demonstrate that the peak of the gate HF switching oscillation current is sensitive to gate-oxide degradation (e.g., 40% before end-of-life), which can be captured online in real-time without interfering with the normal operation of the converter.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Noncontact Monitoring of Gate-Oxide Degradation in SiC MOSFETs Using Gate-Switching Oscillation
The online monitoring of SiC MOSFET gate-oxide degradation presents significant challenges in terms of safety and sensitivity due to the harsh electromagnetic environment and the subtle nature of aging symptoms. To address these challenges, this article proposes a novel non-contact monitoring method for detecting gate-oxide degradation in SiC MOSFETs by extracting the amplitude feature of the turn-on switching oscillation from the gate current. Theoretical analysis reveals that gate-oxide degradation in SiC MOSFETs results in an increase in turn-on time, which subsequently impacts the gate switching oscillation current through the high-frequency (HF) coupling effect of the Miller capacitance. A non-contact monitoring scheme is proposed, utilizing an HF oscillation current sensor and peak detection circuit. To validate the proposed method, an experimental study was conducted on a half-bridge converter equipped with 1.2 kV/30 A SiC MOSFETs. High electric field (HEF) accelerated aging tests were performed under a gate-source voltage condition of Vgs=33 V to investigate the characteristics of gate-oxide degradation. The experimental results demonstrate that the peak of the gate HF switching oscillation current is sensitive to gate-oxide degradation (e.g., 40% before end-of-life), which can be captured online in real-time without interfering with the normal operation of the converter.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 2176-2185
A Novel Method for Cable Defect Location Based on Reflection Coefficient Spectral Variational Mode Decomposition
Frequency domain reflectometry (FDR) based on reflection coefficient spectrum (RCS) is a fast, effective, and non-destructive method for cable defect location. However, due to the impedance mismatch between the tested cable and the signal connection line, as well as multiple reflections of the testing signal within the cable, spurious peaks frequently appear in the location curve, which will affect field judgment and limit the practical applications of FDR. In order to address this issue, an algorithm based on reflection coefficient spectral variational mode decomposition (RCS-VMD) is proposed to improve the conventional cable defect location method based on FDR. The RCS-VMD algorithm determines the order of the RCS decomposition components and identifies the components to be removed based on the principles of VMD. The Pearson correlation coefficient is also introduced as a criterion for removing and reconstructing the VMD components. The simulation and experimental results demonstrate that the improved method can effectively distinguish and eliminate abnormal frequency components caused by the aforementioned factors, thereby suppressing corresponding spurious peaks in the location curve. The peak values of the spurious peaks caused by impedance mismatch at the test terminal and multiple reflections can be reduced by over 90.02%.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (3) , 2176-2185
A Novel Method for Cable Defect Location Based on Reflection Coefficient Spectral Variational Mode Decomposition
Frequency domain reflectometry (FDR) based on reflection coefficient spectrum (RCS) is a fast, effective, and non-destructive method for cable defect location. However, due to the impedance mismatch between the tested cable and the signal connection line, as well as multiple reflections of the testing signal within the cable, spurious peaks frequently appear in the location curve, which will affect field judgment and limit the practical applications of FDR. In order to address this issue, an algorithm based on reflection coefficient spectral variational mode decomposition (RCS-VMD) is proposed to improve the conventional cable defect location method based on FDR. The RCS-VMD algorithm determines the order of the RCS decomposition components and identifies the components to be removed based on the principles of VMD. The Pearson correlation coefficient is also introduced as a criterion for removing and reconstructing the VMD components. The simulation and experimental results demonstrate that the improved method can effectively distinguish and eliminate abnormal frequency components caused by the aforementioned factors, thereby suppressing corresponding spurious peaks in the location curve. The peak values of the spurious peaks caused by impedance mismatch at the test terminal and multiple reflections can be reduced by over 90.02%.
- Open Access
- 29 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (17) , 3462
A Comprehensive Review of Condition Monitoring Technologies for Modular Multilevel Converter (MMC) HVDC Systems
This paper provides an in-depth review of degradation mechanisms and condition monitoring methods for critical components in modular multilevel converter (MMC) high-voltage direct current (HVDC) systems, including insulated gate bipolar transistors (IGBTs), metallized film capacitors, and cross-linked polyethylene (XLPE) DC cables. This study systematically evaluates the strengths and limitations of existing technologies, while also projecting future trends in technological advancements. By exploring the multi-fields-coupled degradation processes of these components, the mechanisms of switching oscillations, and the flexible and controllable applications of MMC, this review offers valuable insights for improving the accuracy, real-time performance, and reliability of component condition monitoring. The findings aim to contribute to the advancement and broader application of MMC HVDC systems in modern power networks.
- 29 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (17) , 3462
Open AccessA Comprehensive Review of Condition Monitoring Technologies for Modular Multilevel Converter (MMC) HVDC Systems
This paper provides an in-depth review of degradation mechanisms and condition monitoring methods for critical components in modular multilevel converter (MMC) high-voltage direct current (HVDC) systems, including insulated gate bipolar transistors (IGBTs), metallized film capacitors, and cross-linked polyethylene (XLPE) DC cables. This study systematically evaluates the strengths and limitations of existing technologies, while also projecting future trends in technological advancements. By exploring the multi-fields-coupled degradation processes of these components, the mechanisms of switching oscillations, and the flexible and controllable applications of MMC, this review offers valuable insights for improving the accuracy, real-time performance, and reliability of component condition monitoring. The findings aim to contribute to the advancement and broader application of MMC HVDC systems in modern power networks.