Longgui Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Longgui Zheng has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Yanlan Hu
Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences
7 shared publications - Qicai Ni
Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, CHINA
6 shared publications - Yezheng Xiao
Hefei Institutes of Physical Science Chinese Academy of Sciences
6 shared publications - Qing Yan
The University of Science and Technology of China, Hefei 230026, People’s Republic of China
5 shared publications - Teng Wang
Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
4 shared publications - Xinxin Zhu
University of Science and Technology of China, Hefei, China
4 shared publications
Latest Publications
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-8
Fault Identification Method for Quench Detection Lines of CSMC and EAST Based on Broadband Impedance Technology
The China Fusion Engineering Test Reactor Central Solenoid Model Coil (CSMC) project, which commenced construction in 2014, is currently in the experimental phase. Experimental advanced superconducting tokamak (EAST) is a superconducting tokamak nuclear fusion experimental device located in China, dedicated to researching the controllable technology of nuclear fusion and currently in continuous operation. The quench protection system serves as the primary safeguard for the operation of the magnets and plays a critical role in ensuring the success of operational experiments. A key component of this system is the voltage acquisition detection lines, which continuously monitor the magnet’s operational status. The safe and reliable operation of these detection lines is essential for the precise functioning of the system. However, the high-voltage detection lines are subjected to harsh environmental conditions, including nuclear radiation, high voltages, ultra-low temperatures, and other extreme factors. Over time, these cables are prone to electrical failures, such as disconnections, short circuits, and insulation damage. This article applies broadband impedance testing [frequency domain reflectometry (FDR)], a mature nondestructive testing technology, to accurately and rapidly detect and locate various electrical faults in the quench detection lines of CSMC and EAST. Real-world field test results for CSMC and EAST verify that FDR can achieve high-precision fault location for twisted-pair and four-core cables, and effectively distinguish typical faults, such as short circuits, open circuits, and water ingress. The application of FDR provides a reliable technical means for the maintenance and safe operation of quench detection systems in superconducting magnet devices, and can prevent latent defects from evolving into permanent faults.
- 2 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-8
Fault Identification Method for Quench Detection Lines of CSMC and EAST Based on Broadband Impedance Technology
The China Fusion Engineering Test Reactor Central Solenoid Model Coil (CSMC) project, which commenced construction in 2014, is currently in the experimental phase. Experimental advanced superconducting tokamak (EAST) is a superconducting tokamak nuclear fusion experimental device located in China, dedicated to researching the controllable technology of nuclear fusion and currently in continuous operation. The quench protection system serves as the primary safeguard for the operation of the magnets and plays a critical role in ensuring the success of operational experiments. A key component of this system is the voltage acquisition detection lines, which continuously monitor the magnet’s operational status. The safe and reliable operation of these detection lines is essential for the precise functioning of the system. However, the high-voltage detection lines are subjected to harsh environmental conditions, including nuclear radiation, high voltages, ultra-low temperatures, and other extreme factors. Over time, these cables are prone to electrical failures, such as disconnections, short circuits, and insulation damage. This article applies broadband impedance testing [frequency domain reflectometry (FDR)], a mature nondestructive testing technology, to accurately and rapidly detect and locate various electrical faults in the quench detection lines of CSMC and EAST. Real-world field test results for CSMC and EAST verify that FDR can achieve high-precision fault location for twisted-pair and four-core cables, and effectively distinguish typical faults, such as short circuits, open circuits, and water ingress. The application of FDR provides a reliable technical means for the maintenance and safe operation of quench detection systems in superconducting magnet devices, and can prevent latent defects from evolving into permanent faults.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-11
Progress in the Application of Optical Fiber in Quench Detection on CFETR CSMC
The CFETR Central Solenoid Model Coil (CSMC) is a largescale hybrid (Nb3Sn/NbTi) superconducting magnet. Current quench detection primarily relies on terminal voltage and auxiliary thermometers, which face limitations regarding fault localization, electromagnetic interference (EMI), and temperature measurement deviations caused by insulation placement. This article proposes a complementary detection scheme using Rayleigh scatteringbased distributed optical fiber and fiber Bragg grating (FBG) technologies. These methods provide natural EMI immunity, fast response times, and continuous spatial monitoring. Distributed optical fibers, encapsulated in seamless steel tubes for mechanical protection, were arranged in the high-field region and near helium tube trigger points. Experimental results demonstrate that the fiber's spectral offset trend is consistent with traditional thermometers. The distributed system successfully captured a 3 K temperature fluctuation at a 20 K baseline within the inner Nb3Sn coil's high-field region. This 3 K rise serves as a high-confidence indicator for thermal runaway confirmation and fault localization, effectively complementing instantaneous but nonlocalized voltage-based detection. To further enhance sensitivity to temperature details around the critical 20 K threshol, PEEK-packaged FBGs were employed as a supplemental measure. This hybrid architecture provides a reliable engineering basis for advanced quench detection in large-scale superconducting magnets.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (4) , 1-11
Progress in the Application of Optical Fiber in Quench Detection on CFETR CSMC
The CFETR Central Solenoid Model Coil (CSMC) is a largescale hybrid (Nb3Sn/NbTi) superconducting magnet. Current quench detection primarily relies on terminal voltage and auxiliary thermometers, which face limitations regarding fault localization, electromagnetic interference (EMI), and temperature measurement deviations caused by insulation placement. This article proposes a complementary detection scheme using Rayleigh scatteringbased distributed optical fiber and fiber Bragg grating (FBG) technologies. These methods provide natural EMI immunity, fast response times, and continuous spatial monitoring. Distributed optical fibers, encapsulated in seamless steel tubes for mechanical protection, were arranged in the high-field region and near helium tube trigger points. Experimental results demonstrate that the fiber's spectral offset trend is consistent with traditional thermometers. The distributed system successfully captured a 3 K temperature fluctuation at a 20 K baseline within the inner Nb3Sn coil's high-field region. This 3 K rise serves as a high-confidence indicator for thermal runaway confirmation and fault localization, effectively complementing instantaneous but nonlocalized voltage-based detection. To further enhance sensitivity to temperature details around the critical 20 K threshol, PEEK-packaged FBGs were employed as a supplemental measure. This hybrid architecture provides a reliable engineering basis for advanced quench detection in large-scale superconducting magnets.
- Open Access
- 25 November 2025
- Published by Elsevier in Superconductivity
- Vol. 16
Design and experimental verification of the quench detection system for the CFETR central solenoid model coil
- 25 November 2025
- Published by Elsevier in Superconductivity
- Vol. 16
Open AccessDesign and experimental verification of the quench detection system for the CFETR central solenoid model coil
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (9) , 1-5
Research on Key Technologies of Quench Detection for CFETR TF Prototype Coil
The design and development of quench detection for the China Fusion Engineering Test Reactor (CFETR) toroidal field (TF) prototype coil is in progress, which is expected to be completed in the fourth quarter of 2025. According to the quench simulation analysis, voltage detection with a threshold of 200 mV and a delay of 2 s satisfies the quench detection design criteria, that is, the hot spot temperature is less than 150 K. The foundation of a successful quench detection system, of course, is the reliable measurement of the original high-voltage signals, high-precision suppression of inductive voltage noises, and accurate execution of quench discrimination. Key technologies include many different things such as optimal design of installation schemes for co-wound tape (CWT) and co-wound wire, automatic wrapping of CWT, welding and extraction of high-voltage taps, transfer of high-voltage wires and cables, high-resolution data acquisition, and sensitive quench discrimination mechanism. The installation process for the primary compensation circuit and the key processes for high-voltage measurement have been developed successfully to manufacture the subcoils of the CFETR TF prototype coil, and the test results meet the design requirements. These technologies can not only further improve the reliability of CFETR TF prototype coil quench detection but also provide robust assurance for the secure and stable operation of international thermonuclear experimental reactor (ITER) and future full superconducting fusion reactors.
- 3 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (9) , 1-5
Research on Key Technologies of Quench Detection for CFETR TF Prototype Coil
The design and development of quench detection for the China Fusion Engineering Test Reactor (CFETR) toroidal field (TF) prototype coil is in progress, which is expected to be completed in the fourth quarter of 2025. According to the quench simulation analysis, voltage detection with a threshold of 200 mV and a delay of 2 s satisfies the quench detection design criteria, that is, the hot spot temperature is less than 150 K. The foundation of a successful quench detection system, of course, is the reliable measurement of the original high-voltage signals, high-precision suppression of inductive voltage noises, and accurate execution of quench discrimination. Key technologies include many different things such as optimal design of installation schemes for co-wound tape (CWT) and co-wound wire, automatic wrapping of CWT, welding and extraction of high-voltage taps, transfer of high-voltage wires and cables, high-resolution data acquisition, and sensitive quench discrimination mechanism. The installation process for the primary compensation circuit and the key processes for high-voltage measurement have been developed successfully to manufacture the subcoils of the CFETR TF prototype coil, and the test results meet the design requirements. These technologies can not only further improve the reliability of CFETR TF prototype coil quench detection but also provide robust assurance for the secure and stable operation of international thermonuclear experimental reactor (ITER) and future full superconducting fusion reactors.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (8) , 1-9
Research on Crosstalk of High-Voltage Signal Transmission Cables for Quench Detection System of Chinese Next-Generation Fusion Device
The quench detection system for next-generation fusion device of China face enormous challenges, as their magnet systems are characterized by significantly higher stored energy and faster discharge rates than those in predecessors like EAST and KSTAR. During both the plasma discharge phase and the superconducting magnet quench current discharge phase, rapid current changes induce high and dynamically varying voltages on magnets, particularly in the Central Solenoid (CS) and Poloidal Field (PF) coils, where kilovolt-level inductive voltages can arise. These high-voltage signals can appear on the quench detection signal cables connected to the magnets, leading to capacitive coupling crosstalk between these cables within the same cable tray. Such crosstalk severely interferes with the quench detection signals, compromising the accurate identification of magnet quenches. This can potentially lead to either false quench detection or a failure in quench detection. To address this, the paper presents a systematic investigation into the crosstalk phenomenon. It begins by characterizing the properties of quench detection signals. Subsequently, an electrical circuit model for signal cable crosstalk is established, and the influencing factors of crosstalk are analyzed. Finally, the model is validated through a dedicated experiment, whose results are used to predict crosstalk levels in the operational environment and to propose effective mitigation strategies to ensure robust quench detection.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (8) , 1-9
Research on Crosstalk of High-Voltage Signal Transmission Cables for Quench Detection System of Chinese Next-Generation Fusion Device
The quench detection system for next-generation fusion device of China face enormous challenges, as their magnet systems are characterized by significantly higher stored energy and faster discharge rates than those in predecessors like EAST and KSTAR. During both the plasma discharge phase and the superconducting magnet quench current discharge phase, rapid current changes induce high and dynamically varying voltages on magnets, particularly in the Central Solenoid (CS) and Poloidal Field (PF) coils, where kilovolt-level inductive voltages can arise. These high-voltage signals can appear on the quench detection signal cables connected to the magnets, leading to capacitive coupling crosstalk between these cables within the same cable tray. Such crosstalk severely interferes with the quench detection signals, compromising the accurate identification of magnet quenches. This can potentially lead to either false quench detection or a failure in quench detection. To address this, the paper presents a systematic investigation into the crosstalk phenomenon. It begins by characterizing the properties of quench detection signals. Subsequently, an electrical circuit model for signal cable crosstalk is established, and the influencing factors of crosstalk are analyzed. Finally, the model is validated through a dedicated experiment, whose results are used to predict crosstalk levels in the operational environment and to propose effective mitigation strategies to ensure robust quench detection.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (8) , 1-9
Simulation of Quench Behavior in CS LTS Magnets for Next-Generation Fusion Devices With Time-Varying Operation
In the next generation of fusion devices, the central solenoid (CS) coil needs to withstand large alternating currents and rapidly changing magnetic fields to achieve plasma breakdown, configuration formation and control. In this study, the quench behavior of a representative submodule (CS1U-LTS) is investigated under time-varying current and magnetic field conditions, where the local field ramp rate reaches approximately 2.5 T/s. This alternating operation mode significantly affects the stability of superconducting magnets. However, the current simulation of superconducting magnet quench is mostly based on steady-state current and steady-state background field, which is difficult to reflect the quench propagation characteristics of superconductors under alternating conditions as the current and magnetic field intensity and direction change. To ensure the safe operation of the CS coils under alternating conditions, this paper first analyzes the quench behavior in a reference case with constant peak current prior to an exponential discharge and determines the protection thresholds required to limit the hot spot temperature to below 150 K: 200 mV voltage threshold and 0.5 s time threshold. The quench response at the positive and negative current peaks during time-varying operation is further analyzed. The results show that under the same protection conditions, the maximum temperature of the CS1U-LTS coil in alternating operation still meets the design requirements. In addition, this paper compares the differences in quench propagation near the two peak points, revealing the impact of alternating operation on quench propagation behavior.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (8) , 1-9
Simulation of Quench Behavior in CS LTS Magnets for Next-Generation Fusion Devices With Time-Varying Operation
In the next generation of fusion devices, the central solenoid (CS) coil needs to withstand large alternating currents and rapidly changing magnetic fields to achieve plasma breakdown, configuration formation and control. In this study, the quench behavior of a representative submodule (CS1U-LTS) is investigated under time-varying current and magnetic field conditions, where the local field ramp rate reaches approximately 2.5 T/s. This alternating operation mode significantly affects the stability of superconducting magnets. However, the current simulation of superconducting magnet quench is mostly based on steady-state current and steady-state background field, which is difficult to reflect the quench propagation characteristics of superconductors under alternating conditions as the current and magnetic field intensity and direction change. To ensure the safe operation of the CS coils under alternating conditions, this paper first analyzes the quench behavior in a reference case with constant peak current prior to an exponential discharge and determines the protection thresholds required to limit the hot spot temperature to below 150 K: 200 mV voltage threshold and 0.5 s time threshold. The quench response at the positive and negative current peaks during time-varying operation is further analyzed. The results show that under the same protection conditions, the maximum temperature of the CS1U-LTS coil in alternating operation still meets the design requirements. In addition, this paper compares the differences in quench propagation near the two peak points, revealing the impact of alternating operation on quench propagation behavior.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Induced Voltage Noise Compensation Method Based on CWW + CNN-BiLSTM-Attention
Induced voltage noise is a significant source of interference in voltage detection, seriously affecting measurement accuracy and system stability. In the complex electromagnetic environment of the Tokamak system, induced voltage noise can exceed 500 V, posing a great challenge to noise suppression in voltage detection signals. This paper presents a two-stage noise compensation approach designed to address the problem. The first stage utilizes a hardware-based Co-wound Wire (CWW) primary compensation method, effectively reducing the induced voltage noise from over 500 V to below 10 V. Building on this foundation, the second stage introduces a deep learning model based on CNN-BiLSTM-Attention as the secondary compensation module, which further reduce the residual noise to below 100 mV over a 1-second window. The proposed method was validated through real-time deployment on the Experimental Advanced Superconducting Tokamak (EAST). Experimental results demonstrate that the method not only achieves excellent compensation effect but also preserves the integrity of critical voltage detection signals throughout operation.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Induced Voltage Noise Compensation Method Based on CWW + CNN-BiLSTM-Attention
Induced voltage noise is a significant source of interference in voltage detection, seriously affecting measurement accuracy and system stability. In the complex electromagnetic environment of the Tokamak system, induced voltage noise can exceed 500 V, posing a great challenge to noise suppression in voltage detection signals. This paper presents a two-stage noise compensation approach designed to address the problem. The first stage utilizes a hardware-based Co-wound Wire (CWW) primary compensation method, effectively reducing the induced voltage noise from over 500 V to below 10 V. Building on this foundation, the second stage introduces a deep learning model based on CNN-BiLSTM-Attention as the secondary compensation module, which further reduce the residual noise to below 100 mV over a 1-second window. The proposed method was validated through real-time deployment on the Experimental Advanced Superconducting Tokamak (EAST). Experimental results demonstrate that the method not only achieves excellent compensation effect but also preserves the integrity of critical voltage detection signals throughout operation.