Daniel McArthur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel McArthur has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
4 shared publications- Stephen Buerger
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
4 shared publications - Derya Z. Tansel
Sandia National Laboratories, Albuquerque, NM 87123, USA
2 shared publications Jonathon Slightam
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications- Steven James Spencer
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications Usdoe National Nuclear Security Administration (Nnsa)
2 shared publications
Latest Publications
- Open Access
Design of a Compliant Six-Wheeled Robot for In-Pipe Inspection with Geometry Constraints
This paper presents the design of SPIINE, a compliant six-wheeled robot for in-pipe inspection with geometry constraints. SPIINE, the Self-Propelled Interior Inspector for Non-destructive-testing (NDT) Examination, is designed to navigate 53 mm (2 in) inner-diameter pipes with tight 90° elbows, including elbows with a curvature radius as small as 76 mm (3 in), while transmitting power and high-resolution video over long tethers verified to 110 m. In straight steel pipe, SPIINE can generate more than eight times its weight in pull force to support towing of NDT sensor payloads. We also present analytical models for estimating robot stiffness and normal-force generation along with prototype hardware tests that evaluate model accuracy. Across the tested displacement range, the vertical reaction-force model achieved a root-mean-square error of 0.21 N; for two tested pipe configurations, pull-force estimates were within 7–13% of the measured values. Hardware experiments demonstrate that SPIINE can traverse a tight 90° elbow in forward and reverse at eight tested entry roll orientations spanning 360°, generate 16.5 N of pull force in straight steel pipe, and traverse more than 60 m of mixed horizontal and vertical pipe with low measured power consumption of approximately 2–3.5 W across representative test segments.
Open AccessDesign of a Compliant Six-Wheeled Robot for In-Pipe Inspection with Geometry Constraints
This paper presents the design of SPIINE, a compliant six-wheeled robot for in-pipe inspection with geometry constraints. SPIINE, the Self-Propelled Interior Inspector for Non-destructive-testing (NDT) Examination, is designed to navigate 53 mm (2 in) inner-diameter pipes with tight 90° elbows, including elbows with a curvature radius as small as 76 mm (3 in), while transmitting power and high-resolution video over long tethers verified to 110 m. In straight steel pipe, SPIINE can generate more than eight times its weight in pull force to support towing of NDT sensor payloads. We also present analytical models for estimating robot stiffness and normal-force generation along with prototype hardware tests that evaluate model accuracy. Across the tested displacement range, the vertical reaction-force model achieved a root-mean-square error of 0.21 N; for two tested pipe configurations, pull-force estimates were within 7–13% of the measured values. Hardware experiments demonstrate that SPIINE can traverse a tight 90° elbow in forward and reverse at eight tested entry roll orientations spanning 360°, generate 16.5 N of pull force in straight steel pipe, and traverse more than 60 m of mixed horizontal and vertical pipe with low measured power consumption of approximately 2–3.5 W across representative test segments.
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
H2C TDIC: Self-Propelled Interior Inspection of Networks of Small Pipes (SPIINe)
Presentation for H2C Technology Development and Integration Coordination Meeting
- 1 August 2025
- Published by Office of Scientific and Technical Information (OSTI)
H2C TDIC: Self-Propelled Interior Inspection of Networks of Small Pipes (SPIINe)
Presentation for H2C Technology Development and Integration Coordination Meeting
- Open Access
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Coordinated Admittance-Impedance Control with Force Excitation for Compliant, Underactuated Aerial Manipulation (Presentation)
3-minute Powerpoint presentation of conference paper content
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessCoordinated Admittance-Impedance Control with Force Excitation for Compliant, Underactuated Aerial Manipulation (Presentation)
3-minute Powerpoint presentation of conference paper content
- Open Access
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Coordinated Admittance-Impedance Control with Force Excitation for Compliant, Underactuated Aerial Manipulation (Poster)
Powerpoint poster of conference paper content
- 1 October 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessCoordinated Admittance-Impedance Control with Force Excitation for Compliant, Underactuated Aerial Manipulation (Poster)
Powerpoint poster of conference paper content
- Open Access
- 1 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Dynamic Shear and Normal Force Detection in a Soft Insole Using Hybrid Optical & Piezoresistive Sensors
Powerpoint presentation for accepted paper at BioRob 2024
- 1 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessDynamic Shear and Normal Force Detection in a Soft Insole Using Hybrid Optical & Piezoresistive Sensors
Powerpoint presentation for accepted paper at BioRob 2024
- Open Access
Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.
Open AccessNanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.