Antonia Iordache
Research Subjects
Research Interests
Antonia Iordache has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Catalin Lungu
Associate Professor, Ph.D., EngTechnical University of Civil Engineering , Faculty of Installation Engineering
1 shared publication - Constantin Lazăr
Faculty of Building Services Engineering, Technical University of Civil Engineering Bucharest, Boulevard Pache Protopopescu 66, 020396 Bucharest, Romania
1 shared publication - Vlad Iordache
CAMBI Research Center, Doctoral School, Faculty of Building Services Engineering, Technical University of Civil Engineering of Bucharest, 020396 Bucharest, Romania
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-9
The Relationship Between Indoor Classroom Noise Levels and the Operating State of the Ventilation System
The evolution of the outdoor climate, combined with the quality requirements imposed on educational environments, leads to special scenarios that are not currently covered by existing noise protection standards. In this study, we present an acoustic analysis of such a scenario, where a noise-generating ventilation unit is installed inside a classroom. In-situ measurements of both sound pressure levels and overall A-weighted sound pressure levels were conducted within the classroom across various operating states of the ventilation equipment. Regardless of the operating mode, the measured noise level remained below the acoustic comfort limit. A low variation in noise levels was observed throughout the interior of the classroom. Slightly higher values were recorded near the noise source, whereas lower values were observed in the corner opposite the equipment. Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
- 1 January 2026
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 21 (1) , 1-9
Open AccessThe Relationship Between Indoor Classroom Noise Levels and the Operating State of the Ventilation System
The evolution of the outdoor climate, combined with the quality requirements imposed on educational environments, leads to special scenarios that are not currently covered by existing noise protection standards. In this study, we present an acoustic analysis of such a scenario, where a noise-generating ventilation unit is installed inside a classroom. In-situ measurements of both sound pressure levels and overall A-weighted sound pressure levels were conducted within the classroom across various operating states of the ventilation equipment. Regardless of the operating mode, the measured noise level remained below the acoustic comfort limit. A low variation in noise levels was observed throughout the interior of the classroom. Slightly higher values were recorded near the noise source, whereas lower values were observed in the corner opposite the equipment. Furthermore, an exponential correlation was established between the indoor noise level variation and the operating state of the ventilation equipment.
- Open Access
- 1 September 2025
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 20 (3) , 11-20
Energy Analysis Regarding the Use of a Hybrid Building Heating System
The heating system proposed to be analyzed in this paper is a hybrid system composed of a heat pump working with mechanical vapor compression and a thermal power plant, each of them providing the thermal power needed for heating volumes, in an accumulation tank where the heat agent is circulated in the heating installation of the consumer. In this context, the analysis of energy efficiency is appropriate because it has a significant impact on technology, taking into account the accelerated depletion of conventional resources, that leads us to the objective of the paper witch is to quantify and compare different installation configurations using heat pumps in order to partially replace conventional energy resources. The analysis refers to the values of thermal and electrical energy used annually by the heat pump and is taking in consideration 3 categories of parameters: the climatic zone in which the building is located, thermal parameters used in the sizing of the central heating installation and the installed capacity of the heat pump used. The obtained results were processed and presented graphically.
- 1 September 2025
- Published by Walter de Gruyter GmbH in Modelling in Civil Environmental Engineering
- Vol. 20 (3) , 11-20
Open AccessEnergy Analysis Regarding the Use of a Hybrid Building Heating System
The heating system proposed to be analyzed in this paper is a hybrid system composed of a heat pump working with mechanical vapor compression and a thermal power plant, each of them providing the thermal power needed for heating volumes, in an accumulation tank where the heat agent is circulated in the heating installation of the consumer. In this context, the analysis of energy efficiency is appropriate because it has a significant impact on technology, taking into account the accelerated depletion of conventional resources, that leads us to the objective of the paper witch is to quantify and compare different installation configurations using heat pumps in order to partially replace conventional energy resources. The analysis refers to the values of thermal and electrical energy used annually by the heat pump and is taking in consideration 3 categories of parameters: the climatic zone in which the building is located, thermal parameters used in the sizing of the central heating installation and the installed capacity of the heat pump used. The obtained results were processed and presented graphically.