ZZZhijun Zhao

Zhijun Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhijun Zhao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dynamic positron emission tomography image reconstruction using spatiotemporal kernel method with deep image prior

    by Zhijun Zhao, Haoyu Zou, Da Liang, Han Liu, Zhiwen Fang, Qiyu Peng

    Background: The inherently ill-posed nature of tomographic reconstruction, combined with the low photon counts in short acquisition frames, poses significant challenges for achieving high-quality dynamic positron emission tomography (PET) images. Recent studies have shown that deep learning methods, particularly the deep image prior (DIP) framework, can effectively enhance PET image reconstruction without requiring external training data. This study aimed to develop a novel DIP-based reconstruction algorithm integrated with a spatiotemporal kernel and to validate its effectiveness in improving the quality of reconstructed dynamic PET images. Methods: We constructed a novel dynamic PET reconstruction algorithm that integrates a spatiotemporal kernel with a DIP framework. Specifically, the reconstruction objective function was formulated as a constrained optimization problem. This problem was solved using the alternating direction method of multipliers (ADMM), alternating between image reconstruction and network parameter updates. Additionally, the algorithm supports list-mode reconstruction, enabling full 3-dimensional (3D) imaging and scalability to large PET systems. Results: Simulation and preclinical studies demonstrated that the proposed method substantially improved image quality compared to conventional methods such as maximum-likelihood expectation maximization (MLEM) with Gaussian post-filtering, kernel expectation maximization (KEM), spatiotemporal kernel expectation maximization (STKEM), as well as deep learning-based methods including DIPRecon and NeuralKEM. It achieved higher signal-to-noise ratio (SNR) and structural similarity index (SSIM), demonstrated good stability during the iterative reconstruction process, and attained a comparable level of contrast recovery coefficient (CRC), while effectively mitigating noise amplification in later iterations. Importantly, the method also demonstrated robust performance under low-count conditions, preserving image quality when conventional methods degrade significantly. Conclusions: By leveraging intrinsic spatiotemporal information, the proposed method improves dynamic PET reconstruction accuracy without external priors. Its modular design enables seamless integration into existing workflows and adapts to diverse PET acquisition protocols. These results underscore its potential for clinical and preclinical dynamic PET imaging, particularly for low-dose or high-resolution scenarios.

  • Impact of inter-crystal scattering on image quality of a dedicated brain PET scanner with DOI capability

    by Haoyu Zou, Zhijun Zhao, Xin Yu, Jinyong Tao, Huiping Zhao, Da Liang, Yibin Zhang, Siwei Xie, Xiaoying Tang, Qiyu Peng

    Objective . Smaller scintillator crystals are commonly used in positron emission tomography (PET) to achieve higher resolution for preclinical research and clinical diagnosis, particularly in brain-dedicated PET scanners with depth-of-interaction (DOI) capability. Although DOI information provides parallax error correction, mispositioning of the line-of-response (LOR) induced by inter-crystal scattering (ICS) can lead to performance degradation, affecting both spatial resolution and image contrast. Previous studies primarily focused on ICS elimination or recovery on PET scanners that are equipped with one-to-one coupled scintillation detectors, with few studies proposing applicable methods for handling ICS events in brain-dedicated PET scanner equipped with light-sharing window detectors and DOI capability. This study specifically evaluates the impact of ICS on a system that have already undergone DOI correction. Approach . By positioning ICS events to their first interaction crystal in Monte Carlo simulations and removing ICS events through a contour-based mask in experimental studies, evaluations of the impact of ICS events on image quality in the context of DOI-corrected systems were conducted. Metrics including spatial resolution and peak-to-valley ratio (PVR) were used for quantitative analysis, while reconstructed images and line profiles provided qualitative comparisons. Main results . Three stages of images were compared in both simulation and experimental studies, revealing that although image quality could be improved by DOI correction, the presence of ICS still affects spatial resolution and image contrast. Applying a contour-based ICS removal method prior to image reconstruction showed a higher PVR, resulting in improved spatial resolution and better lesion detectability for the scanner, though at the cost of sensitivity loss. Significance . Through simulation and experimental evaluation, we have demonstrated that the presence of ICS can severely degrade the performance of high-resolution brain-dedicated PET scanners with DOI decoding capabilities, highlighting the necessity for accurate ICS event classification.


  • DOI Self-Calibration Method Based on Intrinsic Radiation for Positron Emission Tomography

    by Xin Yu, Haoyu Zou, Han Liu, Zhijun Zhao, Da Liang, Xiaoyin Zhang, Huiping Zhao, Jinyong Tao, Wenjing Zhu, Yibin Zhang, et al.

    Depth-of-interaction (DOI) decoding can reduce localization errors in the Line-of-response (LOR), thereby improving positron emission tomography (PET) image quality, especially in high-resolution PET, long-axial PET, and small-aperture PET systems. Current PET detectors are capable of achieving high-resolution DOI decoding, but most methods rely on collimation calibration for each detector. Calibrating all detectors is labor-intensive and complicates subsequent system maintenance. We aim to achieve DOI collimation for PET detectors based on the intrinsic radiation of 176Lu, which allows us to omit the complex step of calibrating DOI for all detectors. This approach allows DOI calibration to be performed automatically during each system operation, simplifying system maintenance. The pixelated LYSO detector in this study consists of LYSO pixels with dimensions of 2 × 2 × 20 mm3. The detector is arranged in an 8×10 array configuration. We obtained the relationship between intrinsic radiation and DOI through Monte Carlo simulations, and the relationship between the MPPC signal ratio (the relative proportion of light detected by different MPPCs from the same crystal, which changes with DOI) and intrinsic radiation through experiments. This allowed us to establish a conversion function between DOI and the MPPC signal ratio. We verified the DOI resolution through collimation testing and demonstrated the improvement in image quality of the DOI self-calibration based on intrinsic radiation method using the Derenzo phantom experiment. We validated the DOI resolution of our method through mechanical collimation experiments at depths of 4 mm, 10 mm, and 16 mm, achieving an average DOI resolution full width at half maximum (FWHM) of 5.2 mm and a Mean Absolute Error (MAE) of 3.6 mm. The images reconstructed with DOI correction obtained through self-collimation demonstrated significantly improved signal-to-noise ratio and spatial resolution compared to images without DOI correction. Specifically, the spatial resolution at an offset of 45 mm improved from 3.0 mm to 2.1 mm. The DOI self-calibration method based on intrinsic radiation provides a practical and efficient solution for calibrating PET detectors without the need to add complex hardware. It should be noted that this method is only applicable to PET systems with detectors employing LSO or LYSO, and therefore this method is based on spontaneous emission of 176Lu. This method has the potential to improve the image quality of PET systems and can be readily integrated into existing detector designs.


  • Development and Performance Evaluation of a Benchtop Small-Animal PET/MRI Scanner

    by Xin Yu, Zhijun Zhao, Han Liu, Da Liang, Wenjing Zhu, Ying Lin, Jiayang Zeng, Chenxuan Liu, Jianfeng Xu, Siwei Xie, et al.

    This study aims to develop a compact, low-cost, and high-performance benchtop small-animal PET/MRI scanner that achieves functional and anatomical image fusion. The system is designed to address challenges in cost reduction, spatial resolution, sensitivity, image quality, and quantitative accuracy. The PET/MRI system was developed with a parallel configuration, integrating a custom-designed PET scanner and a 0.5-T permanent magnet MRI system. Quantitative assessments included spatial resolution, sensitivity, image quality, and quantitative accuracy, as well as signal-to-noise ratio (SNR), geometric distortion (GD), and image uniformity for MRI. The spatial resolution at the axial center is 1.31 mm (axial), 1.26 mm (radial), and 1.22 mm (tangential), with a center sensitivity of 8.05% under a wide energy window. Image quality tests using an IQ phantom demonstrated a uniformity of 10.08 standard deviation, recovery coefficients (RC) ranging from 0.23 to 0.96, and spill-over ratios (SOR) of 0.08 and 0.18 in air and water regions, respectively. The MRI system achieved an SNR of 14.16 in phantom tests, a geometric distortion of less than 1%, and image uniformity of 90.13%. Fusion imaging of PET and MRI demonstrated high registration accuracy in both phantom and mouse studies, with complementary functional and anatomical information. The proposed PET/MRI system achieves high spatial resolution, sensitivity, image quality, and quantitative accuracy while maintaining a simple, low-cost design. The parallel configuration facilitates precise PET/MRI image fusion and allows for efficient multi-animal imaging. The results highlight the potential of this system for preclinical research and its feasibility for future in-vehicle imaging applications. Further optimization of the MRI system and data transmission methods will enhance its performance in high-activity studies and broaden its application scope, with potential applications in preclinical research and invehicle imaging.