KHKatie W. Hulme

Katie W. Hulme

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Katie W. Hulme has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Increasing efficiency in the ACR Digital Mammography QC Manual's DBT Z‐resolution evaluation

    by Ryan F. Fisher, Nicholas B. Bevins, Katie W. Hulme, Colin Schaeffer

    Background: The Z‐resolution evaluation in the ACR Digital Mammography (DM) QC manual measures a pseudo full width half max (pFWHM) from speck group signals through slices of the phantom for comparison to a baseline value. Purpose: The evaluation requires measurement of seven ROIs on up to nine slices, for a potential of up to 63 ROIs. This work evaluates whether measuring fewer ROIs would produce similar results. Methods: Z‐resolution data from 468 surveys from 147 mammography units were retrospectively analyzed. The pFWHM was calculated using the 6‐speck mean (pFWHM 6 ) as described in the ACR manual, as well as using each single speck (pFWHM 1 ), and all combinations of a 2‐speck mean (pFWHM 2 ) using the center and each peripheral speck. Deviation from the respective initial measured pFWHM initial was determined for all units with at least two surveys. Results: The pFWHM 1 had an average absolute error of 6.0% relative to pFWHM 6 across all surveys, compared to 3.9% for pFWHM 2 . For the 111 units with longitudinal data, the mean absolute deviation from pFWHM initial was 7.8% for pFWHM 1 , compared to 5.6% for pFWHM 2 , and 5.1% for pFWHM 6 . For longitudinal testing, pFWHM 6 produced two failures that were related to major component replacement. Both pFWHM 1 and pFWHM 2 methods caught those failures for a false negative rate of 0%. However, pFWHM 1 had a false positive rate of 12.9%, while pFWHM 2 ’s was only 2.8%. No positive test from any method was attributable to actual equipment failure. Conclusion: A single‐speck pFWHM for ACR DM QC resulted in high variability and frequent unit failures for the Z‐resolution evaluation. However, a 2‐speck pFWHM produced results clinically equivalent to the 6‐speck method. Using the 2‐speck method as an alternative methodology for Z‐resolution evaluation achieves similar results with 57% fewer measurements, increasing the efficiency of testing.

  • Open Access

    Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms

    by Matthew Hoerner, Emily L. Marshall, Katie Hulme, Ashley Tao, Suha Alshehri, Shady AlKhazzam, Zaiyang Long, Erin Macdonald, Kathleen Scilla, Ioannis Tsalafoutas

    Background: The IEC exposure index (EI), deviation index (DI), and target exposure index (EI T ), represent critical standardized metrics for the evaluation of exposure and quality in radiographic imaging. Purpose: This work develops and validates a systematic procedure to estimate the EI T for eight of the most common radiography imaging protocols utilizing automatic exposure control (AEC) from measurements acquired under reference conditions. Methods: A model was developed to define the relationship between a systems AEC logic, and an estimation of the EI under flat‐field conditions (EIFFC). Separately, clinical data and acquisition protocol information for resultant EI during patient studies were also collected for the eight protocols studied: Chest posteroanterior (PA), Chest lateral, Abdomen anteroposterior (AP), Pelvis AP, L‐Spine AP, C‐Spine AP, T‐Spine AP, and Ribs AP. Data were collected from 41 x‐ray units spanning seven institutions. For each protocol on each unit the EIFFC was computed based on the acquisition protocol, as well as median EI from clinical exams to produce a scaling factor (SF). Kruskal–Wallis statistical tests were used to compare SF's between vendors and AEC cell configurations. Results: SFs for eight radiographic imaging protocols have been produced per vendor and per AEC cell selection. A workflow has been established for end‐users to follow to apply these SFs to flat‐field measurements taken at their own locations to establish local EI T . Conclusions: The study results show that in seven of the eight imaging protocols, the SFs for most units included in the study report SFs within 1 DI (± 25%) of their respective final vendor reported SF (218/228). The ribs protocol is the exception to this finding (n = 26). SFs have high utility for establishing EI T values on individual x‐ray units and normalizing EI value distributions for quality assurance purposes.


  • Open Access

    Focal spot motion in digital breast tomosynthesis and its effect on spatial resolution

    by Colin J. Schaeffer, Katie W. Hulme, Ashley E. Rubinstein

    Background: Digital breast tomosynthesis (DBT) has become standard practice; however, the acquisition method of DBT between vendors is far from standardized. Currently, there are three commercially available DBT tube motion techniques: (1) continuous motion, (2) step‐and‐shoot, and (3) continuous motion with flying focal spot. Each of these methods represents a trade‐off between total acquisition time and focal spot blur. Purpose: The aim of the study was to characterize the increase in effective focal spot size in DBT relative to standard 2D projections and assess the influence of this increase on spatial resolution using the modulation transfer function (MTF). Methods: Focal spot size was measured for both a 2D acquisition and the 0° DBT projection using a 10 µm slit phantom. Imaging techniques were set to those used for a 2, 4, and 8 cm thick breast of 50/50 adipose/fat composition. MTF curves were measured using a copper edge phantom both at the breast support plane and 4 cm above the breast support. Results: The effective focal spot size increase from 2D to DBT increased with breast thickness for all systems. The continuous motion systems showed the greatest increase in effective focal spot size with percent increases of 101% to 462% depending on unit and breast thickness. The flying focal spot system showed the smallest increase in effective focal spot size in DBT acquisitions, being 3%, 21%, and 25% for a 2, 4, and 8 cm thick breast, respectively. The step‐and‐shoot and flying focal spot systems showed no degradation in MTF curves due to increasing effective focal spot size in DBT acquisitions, while the continuous motion systems showed a reduction in the frequency at which the MTF curve reached 50% of 26%–45%. Conclusion: Both step‐and‐shoot and flying focal spot systems minimized effective focal spot size increase in DBT acquisitions compared to continuous tube motion systems.

  • Open Access

    Comparative Analysis of Total Cost of Ownership: Commercial-Grade versus Diagnostic-Grade Displays in Remote Radiology Workstations

    by Katie Hulme, Jennifer Arnold, Ryan Thomas, Roy Kittelberger, Namita Gandhi, Douglas Nachand, Po-Hao Chen

    With the increasing shift towards remote radiology work, institutions face the challenge of balancing cost-effectiveness with operational reliability. This experiential report presents a comparative analysis of the total cost of ownership (TCO) of commercial-grade displays (WCDs) and diagnostic-grade displays (WDDs) in remote diagnostic stations. We evaluate direct and indirect costs associated with each display type using activity-based costing, focusing on deployment, quality control (QC) processes, and ongoing maintenance. Our findings suggest that while CGDs offer significant initial cost savings, their long-term maintenance requirements, particularly in manual QC, increase recurring expenses. The crossover point for CGDs with monthly QC occurs at approximately five years against mid-level DGDs, potentially making DGDs a more sustainable option over time.