Cheng Long
Cheng Long has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hua Zhang
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
10 shared publications - Yiwen Gao
State Grid Sichuan Electric Power Research Institute, Chengdu 100144, China
7 shared publications - Kun Zheng
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
5 shared publications - Xueneng Su
State Grid Sichuan Electric Power Research Institute, Chengdu 100144, China
5 shared publications - Wei Luo
School of Electrical Engineering, Sichuan University, Wangjiang Campus, Chengdu 610065, China
4 shared publications - Qian Xie
State Grid Sichuan Electric Power Research Institute, Chengdu 100144, China
3 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9173
Linear Active Disturbance Rejection Control Strategy Based on Improved Quasi-Proportional Resonance for the Inner Current Loop of a Grid-Connected Inverter
Nonlinear and asymmetrical loads in microgrids cause severe current distortion and phase unbalance, presenting critical challenges for grid-connected energy storage inverters. Conventional dq-frame Linear Active Disturbance Rejection Control (LADRC) suffers from two key limitations: bandwidth coupling between the observer and controller, and insufficient AC disturbance attenuation. To address these issues, an improved Quasi-Proportional Resonant-LADRC (QPR-LADRC) strategy is proposed for the inner current loop. First, by reconfiguring the disturbance feedback structure within the Linear Extended State Observer (LESO), observer bandwidth is decoupled from controller bandwidth, eliminating parameter tuning conflicts. Second, parallel QPR units tuned at 2ω0 and 6ω0 are integrated into the LESO state-error feedback loop to construct a QPR-LESO. This provides high selective gain for dq-frame AC ripples, enabling zero steady-state error tracking for negative-sequence components and dominant 5th/7th harmonics. Validated via MATLAB/Simulink and StarSim Hardware-in-the-Loop (HIL) testing, the proposed strategy restricts grid-connected current Total Harmonic Distortion (THD) below 2.7% (2.61%, 2.54%, and 2.63% for phases A, B, and C) under severe nonlinear and unbalanced loads. Compared with conventional PI and conventional LADRC schemes, it achieves maximum THD reductions of 1.68% and 3.43%, respectively, while maintaining three-phase current unbalance below 1.1%.
- 16 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (18) , 9173
Open AccessLinear Active Disturbance Rejection Control Strategy Based on Improved Quasi-Proportional Resonance for the Inner Current Loop of a Grid-Connected Inverter
Nonlinear and asymmetrical loads in microgrids cause severe current distortion and phase unbalance, presenting critical challenges for grid-connected energy storage inverters. Conventional dq-frame Linear Active Disturbance Rejection Control (LADRC) suffers from two key limitations: bandwidth coupling between the observer and controller, and insufficient AC disturbance attenuation. To address these issues, an improved Quasi-Proportional Resonant-LADRC (QPR-LADRC) strategy is proposed for the inner current loop. First, by reconfiguring the disturbance feedback structure within the Linear Extended State Observer (LESO), observer bandwidth is decoupled from controller bandwidth, eliminating parameter tuning conflicts. Second, parallel QPR units tuned at 2ω0 and 6ω0 are integrated into the LESO state-error feedback loop to construct a QPR-LESO. This provides high selective gain for dq-frame AC ripples, enabling zero steady-state error tracking for negative-sequence components and dominant 5th/7th harmonics. Validated via MATLAB/Simulink and StarSim Hardware-in-the-Loop (HIL) testing, the proposed strategy restricts grid-connected current Total Harmonic Distortion (THD) below 2.7% (2.61%, 2.54%, and 2.63% for phases A, B, and C) under severe nonlinear and unbalanced loads. Compared with conventional PI and conventional LADRC schemes, it achieves maximum THD reductions of 1.68% and 3.43%, respectively, while maintaining three-phase current unbalance below 1.1%.
- Open Access
Operation-Index-Driven Evaluation of Source-Grid-Load-Storage Distribution Networks via Digital Dynamic Modeling
This paper proposes an operation-index-driven intelligent generation method for distribution network simulation models, integrating model library predefinition, multi-level equivalent modeling, and multi-agent collaboration into an automated pipeline. Three agents collaborate through a unified message bus, task queue, and device model library as follows: Monitor Agent performs time-series data acquisition, national-standard threshold evaluation, and topology verification to trigger modeling tasks; Energy-flow-Model Agent uses a hierarchical model library and LLM (Large Language Model) to automatically match standardized models, parses CIM topology, and applies Thevenin/Ward/three-phase admittance matrix multi-level equivalent modeling to construct Energy Flow Network (EFN) computation graphs; Device-Model-Data Agent supplies missing impedance parameters via a public device standard library. The pipeline automatically generates 15 min granularity current-state assessment models synchronized with operating conditions. Validation on eight consecutive days of 10 kV feeder field measurements (96-time sections/day, 91 transformer areas) shows three-phase voltage mean MAPE of 2.52% and 98.9% correct trigger rate with no false activations or missed detections, achieving end-to-end automation from archive parsing to model generation.
Open AccessOperation-Index-Driven Evaluation of Source-Grid-Load-Storage Distribution Networks via Digital Dynamic Modeling
This paper proposes an operation-index-driven intelligent generation method for distribution network simulation models, integrating model library predefinition, multi-level equivalent modeling, and multi-agent collaboration into an automated pipeline. Three agents collaborate through a unified message bus, task queue, and device model library as follows: Monitor Agent performs time-series data acquisition, national-standard threshold evaluation, and topology verification to trigger modeling tasks; Energy-flow-Model Agent uses a hierarchical model library and LLM (Large Language Model) to automatically match standardized models, parses CIM topology, and applies Thevenin/Ward/three-phase admittance matrix multi-level equivalent modeling to construct Energy Flow Network (EFN) computation graphs; Device-Model-Data Agent supplies missing impedance parameters via a public device standard library. The pipeline automatically generates 15 min granularity current-state assessment models synchronized with operating conditions. Validation on eight consecutive days of 10 kV feeder field measurements (96-time sections/day, 91 transformer areas) shows three-phase voltage mean MAPE of 2.52% and 98.9% correct trigger rate with no false activations or missed detections, achieving end-to-end automation from archive parsing to model generation.
- Open Access
Dynamic Intelligent Method for Voltage Violation Management in High-Renewable-Penetration Distribution Networks
This paper proposes a dynamic intelligent method for voltage violation management in high-renewable-penetration distribution networks. The method employs a dual-agent architecture: DERMS_Agent coordinates task scheduling, data management, and computational resource allocation, while Solution_Agent performs three-phase unbalanced power flow calculation and MIQP-based voltage violation joint optimization. Four key technical contributions are presented. (i) An asymmetric nodal admittance matrix is developed to incorporate transformer tap-phase-shift and capacitor branches within a unified formulation. (ii) Five categories of analytical sensitivities are systematically derived, covering transformer tap, phase shift, and capacitor compensation effects for both voltage regulation and harmonic suppression. (iii) A three-parameter MIQP joint optimization model is constructed with voltage deviation minimization as the objective and three-phase unbalance and resonance avoidance as constraints. (iv) A two-stage hybrid solution strategy combining Ipopt continuous relaxation with Gurobi neighborhood enumeration is designed to achieve real-time solvability. Validation on a real 10 kV feeder with 91 transformer areas over 768 time sections (8 days) demonstrates a 95.6% voltage violation resolution rate within the first three polling cycles and an average single-section solution time of 0.83 s, satisfying the real-time requirements of 15 min operational control cycles.
Open AccessDynamic Intelligent Method for Voltage Violation Management in High-Renewable-Penetration Distribution Networks
This paper proposes a dynamic intelligent method for voltage violation management in high-renewable-penetration distribution networks. The method employs a dual-agent architecture: DERMS_Agent coordinates task scheduling, data management, and computational resource allocation, while Solution_Agent performs three-phase unbalanced power flow calculation and MIQP-based voltage violation joint optimization. Four key technical contributions are presented. (i) An asymmetric nodal admittance matrix is developed to incorporate transformer tap-phase-shift and capacitor branches within a unified formulation. (ii) Five categories of analytical sensitivities are systematically derived, covering transformer tap, phase shift, and capacitor compensation effects for both voltage regulation and harmonic suppression. (iii) A three-parameter MIQP joint optimization model is constructed with voltage deviation minimization as the objective and three-phase unbalance and resonance avoidance as constraints. (iv) A two-stage hybrid solution strategy combining Ipopt continuous relaxation with Gurobi neighborhood enumeration is designed to achieve real-time solvability. Validation on a real 10 kV feeder with 91 transformer areas over 768 time sections (8 days) demonstrates a 95.6% voltage violation resolution rate within the first three polling cycles and an average single-section solution time of 0.83 s, satisfying the real-time requirements of 15 min operational control cycles.
- Open Access
AI-Based Customized Simulation Setup, Process Control, and Result Processing Technology for Distribution Networks
To address the two fundamental contradictions in distribution network digital simulation systems: “diversified simulation requirements versus standardized configuration” and “massive simulation outputs versus sparse decision-making information”, this paper builds upon existing work on Common Information Model (CIM)-based automatic simulation model generation and dynamic voltage regulation simulation and further constructs a user-oriented intelligent simulation service layer. This layer is collaboratively composed of an Orchestration_Agent (simulation orchestration agent) and an Analysis_Agent (result analysis agent), tasked with three responsibilities: based on multi-level simulation granularity (L0–L3) and a simulation template library, leveraging a large language model (LLM) to achieve natural language requirements parsing and automatic workflow orchestration; based on a simulation knowledge graph, implementing parameter recommendation, verification, and anomaly-adaptive recovery for process control; and based on a hybrid architecture of rule templates, statistical analysis, and causal graph models, achieving automatic result analysis, root cause reasoning, and structured report generation, with case feedback driving knowledge base iteration. Validation was conducted on data from a real 10 kV feeder with 91 distribution transformer areas over 30 consecutive days (2880 time cross-sections): comprehensive requirements-parsing accuracy of 96.3%, automatic parameter configuration coverage rate of 94.7%, anomaly identification recall/precision of 94.0%/96.9%, root cause reasoning accuracy of 92.1%, and the median end-to-end time per simulation shortened from approximately 36 min under the manual mode to 4.7 min. The results demonstrate that the proposed service layer provides a viable engineering technology pathway for the evolution of distribution network simulation from tool-oriented to service-oriented.
Open AccessAI-Based Customized Simulation Setup, Process Control, and Result Processing Technology for Distribution Networks
To address the two fundamental contradictions in distribution network digital simulation systems: “diversified simulation requirements versus standardized configuration” and “massive simulation outputs versus sparse decision-making information”, this paper builds upon existing work on Common Information Model (CIM)-based automatic simulation model generation and dynamic voltage regulation simulation and further constructs a user-oriented intelligent simulation service layer. This layer is collaboratively composed of an Orchestration_Agent (simulation orchestration agent) and an Analysis_Agent (result analysis agent), tasked with three responsibilities: based on multi-level simulation granularity (L0–L3) and a simulation template library, leveraging a large language model (LLM) to achieve natural language requirements parsing and automatic workflow orchestration; based on a simulation knowledge graph, implementing parameter recommendation, verification, and anomaly-adaptive recovery for process control; and based on a hybrid architecture of rule templates, statistical analysis, and causal graph models, achieving automatic result analysis, root cause reasoning, and structured report generation, with case feedback driving knowledge base iteration. Validation was conducted on data from a real 10 kV feeder with 91 distribution transformer areas over 30 consecutive days (2880 time cross-sections): comprehensive requirements-parsing accuracy of 96.3%, automatic parameter configuration coverage rate of 94.7%, anomaly identification recall/precision of 94.0%/96.9%, root cause reasoning accuracy of 92.1%, and the median end-to-end time per simulation shortened from approximately 36 min under the manual mode to 4.7 min. The results demonstrate that the proposed service layer provides a viable engineering technology pathway for the evolution of distribution network simulation from tool-oriented to service-oriented.
- Open Access
Research on Bo-BiLSTM-Based Synchronous Load Transfer Control Technology for Distribution Networks
The operational modes and fault characteristics of distribution networks incorporating distributed generation are becoming increasingly complex. This complexity increases the difficulty of predicting switch control action times and leads to scattered samples with data scarcity. Consequently, it imposes higher demands on rapid fault isolation and load transfer control following system failures. To address this issue, this paper proposes a switch action time prediction and synchronous load transfer control method based on Bayesian optimization of bidirectional long short-term memory (Bo-BiLSTM) networks. A distribution network simulation model incorporating distributed generation was constructed using MATLAB/Simulink (R2023a). Three-phase voltage and current at the Point of Common Coupling (PCC) were extracted as feature parameters to establish a switch operation timing database. Bayesian optimization was employed to tune the BiLSTM hyperparameters, constructing the Bo-BiLSTM prediction model to achieve high-precision forecasting of switch operation times under fault conditions. Subsequently, a load-synchronized transfer control strategy was proposed based on the prediction results. A dynamic delay mechanism was designed to achieve “open first and then close” sequential coordinated control. Physical experiments verified that the time difference between opening and closing was controlled within 2–12 milliseconds (ms), meeting the engineering requirement of less than 20 ms. The results demonstrate that the proposed control method enhances switch operation time prediction accuracy while effectively supporting rapid fault isolation and seamless load transfer in distribution networks, thereby improving system reliability and control precision.
Open AccessResearch on Bo-BiLSTM-Based Synchronous Load Transfer Control Technology for Distribution Networks
The operational modes and fault characteristics of distribution networks incorporating distributed generation are becoming increasingly complex. This complexity increases the difficulty of predicting switch control action times and leads to scattered samples with data scarcity. Consequently, it imposes higher demands on rapid fault isolation and load transfer control following system failures. To address this issue, this paper proposes a switch action time prediction and synchronous load transfer control method based on Bayesian optimization of bidirectional long short-term memory (Bo-BiLSTM) networks. A distribution network simulation model incorporating distributed generation was constructed using MATLAB/Simulink (R2023a). Three-phase voltage and current at the Point of Common Coupling (PCC) were extracted as feature parameters to establish a switch operation timing database. Bayesian optimization was employed to tune the BiLSTM hyperparameters, constructing the Bo-BiLSTM prediction model to achieve high-precision forecasting of switch operation times under fault conditions. Subsequently, a load-synchronized transfer control strategy was proposed based on the prediction results. A dynamic delay mechanism was designed to achieve “open first and then close” sequential coordinated control. Physical experiments verified that the time difference between opening and closing was controlled within 2–12 milliseconds (ms), meeting the engineering requirement of less than 20 ms. The results demonstrate that the proposed control method enhances switch operation time prediction accuracy while effectively supporting rapid fault isolation and seamless load transfer in distribution networks, thereby improving system reliability and control precision.
- Open Access
Smooth Droop Control Strategy for Multi-Functional Inverters in Microgrids Considering Unplanned Off-Grid Transition and Dynamic Unbalanced Loads
If unplanned off-grid events occur in microgrids, stable operation is disrupted. In particular, dynamic unbalanced loads, power pulse, and voltage changes also lead to system instability. To overcome these issues, this paper develops a smooth droop control strategy for multi-functional inverters. By introducing a QPR (quasi-proportional resonant) controller, the load voltage regulator is designed to compensate for the harmonic and unbalanced voltages of microgrids. Compared with traditional strategies, the proposed multi-functional inverter can reduce voltage pulses by more than 60%, and the off-grid voltage THD (total harmonic distortion) is decreased from 7% to less than 3%. At the same time, dynamic unbalanced loads and non-linear dynamic loads are both considered, and the derived strategy achieves smoother grid-connected and off-grid switching. In grid-connected mode (the microgrid connects to the distribution network at the PCC), the peak voltages and overshoots across transitions are definitely decreased, and continuous monitoring shows that the grid’s current THD stays steadily below 3%. This meets compatibility requirements, avoids harmonic interference on distribution networks, and follows the core principle of IEC TS 62898-1:2023. The simulation and experimental results verify the effectiveness of the proposed multi-function inverter control strategy for grid-connected inverters.
Open AccessSmooth Droop Control Strategy for Multi-Functional Inverters in Microgrids Considering Unplanned Off-Grid Transition and Dynamic Unbalanced Loads
If unplanned off-grid events occur in microgrids, stable operation is disrupted. In particular, dynamic unbalanced loads, power pulse, and voltage changes also lead to system instability. To overcome these issues, this paper develops a smooth droop control strategy for multi-functional inverters. By introducing a QPR (quasi-proportional resonant) controller, the load voltage regulator is designed to compensate for the harmonic and unbalanced voltages of microgrids. Compared with traditional strategies, the proposed multi-functional inverter can reduce voltage pulses by more than 60%, and the off-grid voltage THD (total harmonic distortion) is decreased from 7% to less than 3%. At the same time, dynamic unbalanced loads and non-linear dynamic loads are both considered, and the derived strategy achieves smoother grid-connected and off-grid switching. In grid-connected mode (the microgrid connects to the distribution network at the PCC), the peak voltages and overshoots across transitions are definitely decreased, and continuous monitoring shows that the grid’s current THD stays steadily below 3%. This meets compatibility requirements, avoids harmonic interference on distribution networks, and follows the core principle of IEC TS 62898-1:2023. The simulation and experimental results verify the effectiveness of the proposed multi-function inverter control strategy for grid-connected inverters.
- Open Access
- 16 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3299
Research on Synchronous Transfer Control Technology for Distribution Network Load Based on Imprecise Probability
As the penetration rate of distributed power sources increases and distribution network structures grow increasingly complex, the uncertainty in switch action control during load transfer has become a critical issue affecting grid safety and reliability. Traditional control methods based on precise probability-based predictive control are susceptible to bias introduced by prior settings under small-sample conditions, making it difficult to meet the stringent requirements of time-synchronized control. To address this, this study proposes an imprecise probability-based synchronous load transfer control method for distribution networks. By integrating the Imprecise Dirichlet model (IDM) with a Naive Credal Classifier (NCC), it constructs an interval predictive control model for switching action timing. This approach effectively mitigates the prior dependency issue and enhances estimation robustness under small-sample conditions. Combined with a dynamic delay strategy, this approach strictly controls the interval between disconnection and reconnection actions within 20 ms, preventing circulating current risks and ensuring transfer reliability. The simulation and experimental results demonstrate that the proposed method outperforms traditional Bayesian classifiers in both time prediction control accuracy and model robustness, providing a theoretical foundation and a reference for engineering applications for secure action control in distribution networks.
- 16 October 2025
- Published by MDPI AG in Mathematics
- Vol. 13 (20) , 3299
Open AccessResearch on Synchronous Transfer Control Technology for Distribution Network Load Based on Imprecise Probability
As the penetration rate of distributed power sources increases and distribution network structures grow increasingly complex, the uncertainty in switch action control during load transfer has become a critical issue affecting grid safety and reliability. Traditional control methods based on precise probability-based predictive control are susceptible to bias introduced by prior settings under small-sample conditions, making it difficult to meet the stringent requirements of time-synchronized control. To address this, this study proposes an imprecise probability-based synchronous load transfer control method for distribution networks. By integrating the Imprecise Dirichlet model (IDM) with a Naive Credal Classifier (NCC), it constructs an interval predictive control model for switching action timing. This approach effectively mitigates the prior dependency issue and enhances estimation robustness under small-sample conditions. Combined with a dynamic delay strategy, this approach strictly controls the interval between disconnection and reconnection actions within 20 ms, preventing circulating current risks and ensuring transfer reliability. The simulation and experimental results demonstrate that the proposed method outperforms traditional Bayesian classifiers in both time prediction control accuracy and model robustness, providing a theoretical foundation and a reference for engineering applications for secure action control in distribution networks.
- Open Access
- 26 September 2025
- Published by MDPI AG in Preprints.org
Research on Bo-BiLSTM-Based Synchronous Load Transfer Control Technology for Distribution Networks
The operational modes and fault characteristics of distribution networks incorporating distributed generation are becoming increasingly complex. This complexity increases the difficulty of predicting switch control action times, leads to scattered samples and data scarcity, and imposes higher demands on rapid fault isolation and load transfer control following system failures. To address this issue, this paper proposes a switch action time prediction and synchronous load transfer control method based on Bayesian optimization of bidirectional long short-term memory networks (Bo-BiLSTM). A distribution network simulation model incorporating distributed generation was constructed using MATLAB/Simulink. Three-phase voltage and current at the point of common coupling (PCC) were extracted as feature parameters to establish a switch operation timing database. Bayesian optimization was employed to tune the BiLSTM hyperparameters, constructing the Bo-BiLSTM prediction model to achieve high-precision forecasting of switch operation times under fault conditions. Subsequently, a load-synchronized transfer control strategy was proposed based on the prediction results. A dynamic delay mechanism was designed to achieve “disconnect-first, reconnect-later” sequential coordinated control. Physical experiments verified that the time difference between disconnection and reconnection was controlled within 2–12 ms, meeting the engineering requirement of less than 20 ms. Results demonstrate that the proposed control method enhances switch operation time prediction accuracy while effectively supporting rapid fault isolation and seamless load transfer in distribution networks, thereby improving system reliability and control precision.
- 26 September 2025
- Published by MDPI AG in Preprints.org
Open AccessResearch on Bo-BiLSTM-Based Synchronous Load Transfer Control Technology for Distribution Networks
The operational modes and fault characteristics of distribution networks incorporating distributed generation are becoming increasingly complex. This complexity increases the difficulty of predicting switch control action times, leads to scattered samples and data scarcity, and imposes higher demands on rapid fault isolation and load transfer control following system failures. To address this issue, this paper proposes a switch action time prediction and synchronous load transfer control method based on Bayesian optimization of bidirectional long short-term memory networks (Bo-BiLSTM). A distribution network simulation model incorporating distributed generation was constructed using MATLAB/Simulink. Three-phase voltage and current at the point of common coupling (PCC) were extracted as feature parameters to establish a switch operation timing database. Bayesian optimization was employed to tune the BiLSTM hyperparameters, constructing the Bo-BiLSTM prediction model to achieve high-precision forecasting of switch operation times under fault conditions. Subsequently, a load-synchronized transfer control strategy was proposed based on the prediction results. A dynamic delay mechanism was designed to achieve “disconnect-first, reconnect-later” sequential coordinated control. Physical experiments verified that the time difference between disconnection and reconnection was controlled within 2–12 ms, meeting the engineering requirement of less than 20 ms. Results demonstrate that the proposed control method enhances switch operation time prediction accuracy while effectively supporting rapid fault isolation and seamless load transfer in distribution networks, thereby improving system reliability and control precision.
- Open Access
- 18 September 2025
- Published by MDPI AG in Preprints.org
Research on Distribution Network Load Synchronous Transfer Control Technology Based on Imprecise Probability
As the penetration rate of distributed power sources increases and distribution network structures grow increasingly complex, the uncertainty in switch action control during load transfer has become a critical issue affecting grid safety and reliability. Traditional control methods based on precise probability-based predictive control are susceptible to bias introduced by prior settings under small-sample conditions, making it difficult to meet the stringent requirements of time-synchronized control. To address this, this study proposes an imprecise probability-based synchronous load transfer control method for distribution networks. By integrating the Imprecise Dirichlet model (IDM) with a Naive Credal Classifier (NCC), it constructs an interval predictive control model for switching action timing. This approach effectively mitigates the prior-dependency issue and enhances estimation robustness under small sample conditions. Combined with a dynamic delay strategy, this approach strictly controls the interval between disconnection and reconnection actions within 20 ms, preventing circulating current risks and ensuring transfer reliability. Simulation and experimental results demonstrate that the proposed method outperforms traditional Bayesian classifiers in both time prediction control accuracy and model robustness, providing a theoretical foundation and a reference for engineering applications for secure action control in distribution networks.
- 18 September 2025
- Published by MDPI AG in Preprints.org
Open AccessResearch on Distribution Network Load Synchronous Transfer Control Technology Based on Imprecise Probability
As the penetration rate of distributed power sources increases and distribution network structures grow increasingly complex, the uncertainty in switch action control during load transfer has become a critical issue affecting grid safety and reliability. Traditional control methods based on precise probability-based predictive control are susceptible to bias introduced by prior settings under small-sample conditions, making it difficult to meet the stringent requirements of time-synchronized control. To address this, this study proposes an imprecise probability-based synchronous load transfer control method for distribution networks. By integrating the Imprecise Dirichlet model (IDM) with a Naive Credal Classifier (NCC), it constructs an interval predictive control model for switching action timing. This approach effectively mitigates the prior-dependency issue and enhances estimation robustness under small sample conditions. Combined with a dynamic delay strategy, this approach strictly controls the interval between disconnection and reconnection actions within 20 ms, preventing circulating current risks and ensuring transfer reliability. Simulation and experimental results demonstrate that the proposed method outperforms traditional Bayesian classifiers in both time prediction control accuracy and model robustness, providing a theoretical foundation and a reference for engineering applications for secure action control in distribution networks.
- Open Access
High-Impedance Grounding Fault Protection in Distribution Networks Based on Single-Phase Isolation Transformer and Phase-Edge Additional Capacitance
High impedance grounding faults (HIGFs) are a common yet difficult-to-detect issue in distribution networks. Characterized by low fault currents and prolonged durations, they pose a significant risk of triggering secondary hazards such as wildfires. Existing HIGF prevention and control technologies face challenges in effectively addressing arc ignition, fault current limitation, and wildfire mitigation. To tackle these limitations, this paper proposes a novel asymmetric operational structure incorporating a single-phase isolation transformer and supplementary edge-phase capacitance. Through theoretical modeling and simulation analysis, the interrelations among fault current, phase voltage, zero-sequence voltage, and HIGF characteristics are systematically explored. A coordinated control strategy is developed to optimize three-phase voltage distribution within the distribution network. Simulation results demonstrate that the proposed configuration significantly reduces edge-phase voltages, suppresses fault current levels, prevents arc initiation, extends arc ignition delay times, and consequently mitigates wildfire risk. This study presents a new technical pathway for HIGF prevention and control, offering both practical engineering value and theoretical insight.
Open AccessHigh-Impedance Grounding Fault Protection in Distribution Networks Based on Single-Phase Isolation Transformer and Phase-Edge Additional Capacitance
High impedance grounding faults (HIGFs) are a common yet difficult-to-detect issue in distribution networks. Characterized by low fault currents and prolonged durations, they pose a significant risk of triggering secondary hazards such as wildfires. Existing HIGF prevention and control technologies face challenges in effectively addressing arc ignition, fault current limitation, and wildfire mitigation. To tackle these limitations, this paper proposes a novel asymmetric operational structure incorporating a single-phase isolation transformer and supplementary edge-phase capacitance. Through theoretical modeling and simulation analysis, the interrelations among fault current, phase voltage, zero-sequence voltage, and HIGF characteristics are systematically explored. A coordinated control strategy is developed to optimize three-phase voltage distribution within the distribution network. Simulation results demonstrate that the proposed configuration significantly reduces edge-phase voltages, suppresses fault current levels, prevents arc initiation, extends arc ignition delay times, and consequently mitigates wildfire risk. This study presents a new technical pathway for HIGF prevention and control, offering both practical engineering value and theoretical insight.