ZXZhiyu Xiao

Zhiyu Xiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiyu Xiao has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Zhengfei Zhuang

    MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China

    3 shared publications
  • Min Hu

    MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China

    2 shared publications
  • Dingshan Zheng

    College of Biophotonics, South China Normal University, Guangzhou, P. R. China

    1 shared publication
  • Lei Liu

    College of Photonics, School of Optoelectronic Science and Engineering, South China Normal University , Tianhe District, Guangzhou 510898

    1 shared publication
  • Lingmin Xie

    MOE Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, School of Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510631, China

    1 shared publication
  • Lingmin Xie

    College of Photonics, School of Optoelectronic Science and Engineering, South China Normal University , Tianhe District, Guangzhou 510898

    1 shared publication

Latest Publications

  • Open Access

    Fluorescence resonance energy transfer as a molecular ruler: Quantitative and semi-quantitative measurement approaches and emerging AI-enabled tools

    by Shencai Peng, Shuo Tang, Dingshan Zheng, Zhiyu Xiao, Zhengyin Wang, Min Hu, Zhengfei Zhuang

    Fluorescence Resonance Energy Transfer (FRET) is an optical tool for probing nanoscale molecular interactions and dynamics. Although widely used, reliable quantitative and semi-quantitative estimation of FRET efficiency remains challenging because different measurement modalities rely on distinct photophysical assumptions, correction steps, and analytical models. In this review, we summarize major strategies for FRET efficiency estimation, including intensity-based approaches (e.g., sensitized emission and acceptor photobleaching), lifetime-based approaches (FLIM-FRET and time-resolved FRET), and representative assay formats such as FRET two-hybrid analysis, along with spectral, single-molecule, two-photon, and super-resolution variants. For each category, we compare the underlying physical principles, typical error sources and corrections, representative modeling strategies, and practical applicability across experimental constraints. We further synthesize recent advances in optical imaging and computational modeling and propose a practical workflow for integrating artificial intelligence into FRET quantification, covering data quality control, automated region-of-interest selection, calibration and parameter inference, and validation aimed at reproducible results. Finally, we discuss emerging opportunities enabled by on-instrument analytics (Edge AI and TinyML) for low-latency acquisition and analysis, and outline future directions toward high-throughput, cross-scale imaging and standardized quantitative workflows.


  • MDM2/p53-based live-cell quantitative FRET imaging for apoptosis drug discovery

    by Zhiyu Xiao, Lingmin Xie, Ziru Wu, Xinghong Cai, Zhengfei Zhuang, Tongsheng Chen


  • AutoFRET: An Image Processing-Based ROI Automated Selection Method for Quantitative FRET Measurements

    by Weijing Liang, Zhiyu Xiao, Lingmin Xie, Xingbang Xiong, Lei Liu, Min Hu, Zhengfei Zhuang

    The emission-based fluorescence resonance energy transfer (E-FRET), renowned for its rapid detection, noninvasiveness towards fluorophores, and compatibility with both wide-field and confocal microscopy, is extensively employed in dynamically monitoring intermolecular interactions within living cells. However, E-FRET requires manual screening of hundreds to thousands of images for regions meeting specific criteria, a labor-intensive process devoid of mature automation solutions. In this article, we introduce AutoFRET, the automated and efficient solution tailored for E-FRET experimentation. AutoFRET harnesses image processing algorithms to swiftly and precisely identify target regions amidst vast image datasets. Furthermore, to mitigate the impact of dead cells in images on experimental results, we devise a novel cell morphology-based approach for their identification and exclusion. AutoFRET significantly reduces the time commitment for E-FRET experimental data analysis, condensing the entire process to the minute level. Comprehensive experimental evaluations reveal an average accuracy exceeding 95% for AutoFRET. This research presents a highly automated and reliable platform that expeditiously quantifies molecular interactions in living cells leveraging FRET technology, poised to contribute to advancements in quantitative biological research.