Mona Bazooband
Mona Bazooband has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Hamed Bahrami Maleki
Department of Prosthodontics, School of Dentistry Ilam University of Medical Sciences Ilam Iran
1 shared publication- Hamed Bahrami Maleki
Department of Prosthodontics, School of Dentistry, Ilam University of Medical Sciences, Ilam, Iran
1 shared publication - Nima Ahmadyan
Department of Prosthodontics, School of Dentistry, Ilam University of Medical Sciences, Ilam, Iran
1 shared publication Parviz Amini
Department of Prosthodontics, School of Dentistry Kerman University of Medical Sciences Kerman Iran
1 shared publication
Latest Publications
- Open Access
- 2 October 2026
- Published by Springer Nature in BMC Oral Health
Fracture resistance and failure modes of post and core systems in endodontically treated teeth with severely enlarged root canals: an in vitro study
Background: This in vitro study compared fracture resistance and failure mode distribution among endodontically treated maxillary second premolars with experimentally enlarged canals restored with custom CAD/CAM zirconia, cast nickel–chromium (Ni-Cr), cast gold-colored copper-based dental alloy (NPG) post-and-core systems, or a prefabricated glass fiber post with a composite core. Methods: Forty extracted maxillary second premolars underwent root canal treatment and coronal canal enlargement, leaving an approximately 1.5 mm coronal dentin wall at four measured sites. Specimens were randomly allocated to four groups ( n = 10), restored with standardized full metal crowns, thermocycled, and subjected to cyclic mechanical loading. Fracture resistance and failure modes were evaluated. Data were analyzed using Kruskal–Wallis and Dunn’s tests with Bonferroni correction; failure modes were analyzed using Fisher’s exact test (α = 0.05). Results: Median fracture resistance was 492.27 N (IQR, 345.90–688.75) for the custom CAD/CAM zirconia post-and-core group, 369.44 N (IQR, 245.75–547.16) for the cast Ni-Cr post-and-core group, 173.66 N (IQR, 150.21–320.40) for the cast NPG post-and-core group, and 127.96 N (IQR, 100.13–143.03) for the glass fiber post group. Fracture resistance distributions differed significantly (H = 17.918, df = 3, P <.001). The glass fiber post group had lower fracture resistance than the custom CAD/CAM zirconia (adjusted P <.001) and cast Ni-Cr post-and-core groups (adjusted P =.012). The custom CAD/CAM zirconia post-and-core group had the highest observed median but did not differ significantly from the cast Ni-Cr (adjusted P = 1.000) or cast NPG post-and-core group (adjusted P =.077). Failure mode distribution also differed significantly ( P =.010); favorable failures occurred in 70% of fiber post specimens, 30% of NPG post-and-core specimens, and 10% of both zirconia and Ni-Cr post-and-core specimens. Conclusions: The tested systems differed in fracture resistance and failure mode distribution. The custom CAD/CAM zirconia post-and-core group had the highest observed median fracture resistance; however, it was not statistically different from either the cast Ni-Cr or cast NPG post-and-core group. The prefabricated glass fiber post group had significantly lower fracture resistance than the custom CAD/CAM zirconia and cast Ni-Cr post-and-core groups but showed the greatest proportion of favorable failures.
- 2 October 2026
- Published by Springer Nature in BMC Oral Health
Open AccessFracture resistance and failure modes of post and core systems in endodontically treated teeth with severely enlarged root canals: an in vitro study
Background: This in vitro study compared fracture resistance and failure mode distribution among endodontically treated maxillary second premolars with experimentally enlarged canals restored with custom CAD/CAM zirconia, cast nickel–chromium (Ni-Cr), cast gold-colored copper-based dental alloy (NPG) post-and-core systems, or a prefabricated glass fiber post with a composite core. Methods: Forty extracted maxillary second premolars underwent root canal treatment and coronal canal enlargement, leaving an approximately 1.5 mm coronal dentin wall at four measured sites. Specimens were randomly allocated to four groups ( n = 10), restored with standardized full metal crowns, thermocycled, and subjected to cyclic mechanical loading. Fracture resistance and failure modes were evaluated. Data were analyzed using Kruskal–Wallis and Dunn’s tests with Bonferroni correction; failure modes were analyzed using Fisher’s exact test (α = 0.05). Results: Median fracture resistance was 492.27 N (IQR, 345.90–688.75) for the custom CAD/CAM zirconia post-and-core group, 369.44 N (IQR, 245.75–547.16) for the cast Ni-Cr post-and-core group, 173.66 N (IQR, 150.21–320.40) for the cast NPG post-and-core group, and 127.96 N (IQR, 100.13–143.03) for the glass fiber post group. Fracture resistance distributions differed significantly (H = 17.918, df = 3, P <.001). The glass fiber post group had lower fracture resistance than the custom CAD/CAM zirconia (adjusted P <.001) and cast Ni-Cr post-and-core groups (adjusted P =.012). The custom CAD/CAM zirconia post-and-core group had the highest observed median but did not differ significantly from the cast Ni-Cr (adjusted P = 1.000) or cast NPG post-and-core group (adjusted P =.077). Failure mode distribution also differed significantly ( P =.010); favorable failures occurred in 70% of fiber post specimens, 30% of NPG post-and-core specimens, and 10% of both zirconia and Ni-Cr post-and-core specimens. Conclusions: The tested systems differed in fracture resistance and failure mode distribution. The custom CAD/CAM zirconia post-and-core group had the highest observed median fracture resistance; however, it was not statistically different from either the cast Ni-Cr or cast NPG post-and-core group. The prefabricated glass fiber post group had significantly lower fracture resistance than the custom CAD/CAM zirconia and cast Ni-Cr post-and-core groups but showed the greatest proportion of favorable failures.
- Open Access
- 16 September 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70222
The Effects of Laboratory Contamination of Implant Abutment Screw and Connection on Reverse Torque Value – An In Vitro Study
Objectives: This in vitro experimental study aimed to evaluate the effects of laboratory contamination of implant abutment screws and connection surfaces on reverse torque values (RTVs), as an indicator of screw preload loss.Material and Methods: Forty‐five Dentis One Q implants and 45 CCM UCLA abutments were randomly assigned into three groups (n = 15 per group). Group 1 (control) involved uncontaminated abutments and screws with no restorations. Group 2 (screw contamination) used new abutments attached with screws contaminated by laboratory materials (porcelain powder, metal debris, and polishing paste). Group 3 (connection contamination) included screw‐retained restorations fabricated under contaminated conditions and attached using new screws. All samples were subjected to standardized torque (250 N·cm), thermocycling (1500 cycles between 5°C and 55°C), and subsequent RTV measurement. One‐way ANOVA and Tukey's post hoc tests were used for statistical analysis (α = 0.05).Results: Mean RTVs (SD) were 218 (0.15) N·cm (control), 181 (0.14) N·cm (screw contamination), and 207 (0.11) N·cm (connection contamination). RTVs in the screw contamination group were significantly lower than both the control (p < 0.001) and connection contamination groups (p < 0.001). The difference between the control and connection contamination groups was not statistically significant (p = 0.08).Conclusions: Laboratory contamination of implant components can significantly reduce reverse torque values, particularly in cases of screw contamination, indicating an increased risk of screw loosening. Contamination control during prosthetic procedures is essential to maintaining implant stability.
- 16 September 2025
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70222
Open AccessThe Effects of Laboratory Contamination of Implant Abutment Screw and Connection on Reverse Torque Value – An In Vitro Study
Objectives: This in vitro experimental study aimed to evaluate the effects of laboratory contamination of implant abutment screws and connection surfaces on reverse torque values (RTVs), as an indicator of screw preload loss.Material and Methods: Forty‐five Dentis One Q implants and 45 CCM UCLA abutments were randomly assigned into three groups (n = 15 per group). Group 1 (control) involved uncontaminated abutments and screws with no restorations. Group 2 (screw contamination) used new abutments attached with screws contaminated by laboratory materials (porcelain powder, metal debris, and polishing paste). Group 3 (connection contamination) included screw‐retained restorations fabricated under contaminated conditions and attached using new screws. All samples were subjected to standardized torque (250 N·cm), thermocycling (1500 cycles between 5°C and 55°C), and subsequent RTV measurement. One‐way ANOVA and Tukey's post hoc tests were used for statistical analysis (α = 0.05).Results: Mean RTVs (SD) were 218 (0.15) N·cm (control), 181 (0.14) N·cm (screw contamination), and 207 (0.11) N·cm (connection contamination). RTVs in the screw contamination group were significantly lower than both the control (p < 0.001) and connection contamination groups (p < 0.001). The difference between the control and connection contamination groups was not statistically significant (p = 0.08).Conclusions: Laboratory contamination of implant components can significantly reduce reverse torque values, particularly in cases of screw contamination, indicating an increased risk of screw loosening. Contamination control during prosthetic procedures is essential to maintaining implant stability.