The Effects of Laboratory Contamination of Implant Abutment Screw and Connection on Reverse Torque Value – An In Vitro Study
Authors:
Open Access
- 16 September 2025
- journal article
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 11 (5) , e70222
Abstract
Objectives: This in vitro experimental study aimed to evaluate the effects of laboratory contamination of implant abutment screws and connection surfaces on reverse torque values (RTVs), as an indicator of screw preload loss.Material and Methods: Forty‐five Dentis One Q implants and 45 CCM UCLA abutments were randomly assigned into three groups (n = 15 per group). Group 1 (control) involved uncontaminated abutments and screws with no restorations. Group 2 (screw contamination) used new abutments attached with screws contaminated by laboratory materials (porcelain powder, metal debris, and polishing paste). Group 3 (connection contamination) included screw‐retained restorations fabricated under contaminated conditions and attached using new screws. All samples were subjected to standardized torque (250 N·cm), thermocycling (1500 cycles between 5°C and 55°C), and subsequent RTV measurement. One‐way ANOVA and Tukey's post hoc tests were used for statistical analysis (α = 0.05).Results: Mean RTVs (SD) were 218 (0.15) N·cm (control), 181 (0.14) N·cm (screw contamination), and 207 (0.11) N·cm (connection contamination). RTVs in the screw contamination group were significantly lower than both the control (p < 0.001) and connection contamination groups (p < 0.001). The difference between the control and connection contamination groups was not statistically significant (p = 0.08).Conclusions: Laboratory contamination of implant components can significantly reduce reverse torque values, particularly in cases of screw contamination, indicating an increased risk of screw loosening. Contamination control during prosthetic procedures is essential to maintaining implant stability.Keywords
This publication has 30 references indexed in Scilit:
- Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connectionsThe Journal of Prosthetic Dentistry, 2020
- The Relationship Between Time of Retightening and Preload Loss of Abutment Screws for Two Different Implant Designs: An In Vitro StudyJournal of Oral Implantology, 2020
- Mechanism of and factors associated with the loosening of the implant abutment screw: A reviewJournal of Esthetic and Restorative Dentistry, 2019
- Influence of the difference between implant body and screw materials on abutment screw looseningDental Materials Journal, 2019
- A Comparison of Torque Stress on Abutment Screw of External Hexagon and Morse Taper ImplantThe Journal of Contemporary Dental Practice, 2018
- The influence of implant–abutment connection on the screw loosening and microleakageInternational Journal of Implant Dentistry, 2018
- The Effect of Contamination of Implant Screws on Reverse TorqueThe International Journal of Oral and Maxillofacial Implants, 2015
- Effect of Fluid Contamination on Reverse Torque Values in Bone-Level ImplantsImplant Dentistry, 2014
- Implant Abutment Screw Reverse Torque Values Before and After Plasma CleaningThe International Journal of Prosthodontics, 2013
- The dynamic natures of implant loadingThe Journal of Prosthetic Dentistry, 2009