OGOmar A. M. Gharib
Omar A. M. Gharib
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Omar A. M. Gharib has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Carass
Johns Hopkins University
1 shared publication - Blake E. Dewey
Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, MD, USA
1 shared publication - Jerry L. Prince
Johns Hopkins University
1 shared publication - Samuel W. Remedios
Johns Hopkins University
1 shared publication
Latest Publications
- 20 September 2025
- Published by Springer Nature
- Vol. 15961, 186-196
Exploring the Feasibility of Zero-Shot Super-Resolution in Preclinical Imaging
Preclinical imaging studies are vital to the research, development, and evaluation of new medical therapies. Images acquired during these studies often have high in-plane resolution but low through-plane resolution, resulting in highly anisotropic volumes that hamper downstream volumetric analysis. Additionally, since there are no image acquisition standards across studies, training data for conventional supervised super-resolution (SR) methods is limited. In this work, we compare two SR methods that do not require additional training data. The first is ECLARE, a self-SR approach that creates its own training data from in-plane patches drawn from the anisotropic volume. The second is Biplanar Denoising diffusion null space model (DDNM) Averaging (BiDA), a proposed method leveraging two independently pre-trained denoising diffusion probabilistic models and the DDNM posterior sampling technique. We evaluate both methods first on rat data at two scale factors (\(2.5\times \) and \(5\times \)) and compare signal recovery and downstream task performance. We further evaluate these methods on a different species (mice) to measure their generalizability. Both methods experimentally resulted in good signal recovery performance, but only the images super-resolved by BiDA were accurately skullstripped downstream. Although both methods performed well on the in-domain rat data, BiDA did not fully generalize to the out-of-domain mouse data.- 20 September 2025
- Published by Springer Nature
- Vol. 15961, 186-196
Exploring the Feasibility of Zero-Shot Super-Resolution in Preclinical Imaging
Preclinical imaging studies are vital to the research, development, and evaluation of new medical therapies. Images acquired during these studies often have high in-plane resolution but low through-plane resolution, resulting in highly anisotropic volumes that hamper downstream volumetric analysis. Additionally, since there are no image acquisition standards across studies, training data for conventional supervised super-resolution (SR) methods is limited. In this work, we compare two SR methods that do not require additional training data. The first is ECLARE, a self-SR approach that creates its own training data from in-plane patches drawn from the anisotropic volume. The second is Biplanar Denoising diffusion null space model (DDNM) Averaging (BiDA), a proposed method leveraging two independently pre-trained denoising diffusion probabilistic models and the DDNM posterior sampling technique. We evaluate both methods first on rat data at two scale factors (\(2.5\times \) and \(5\times \)) and compare signal recovery and downstream task performance. We further evaluate these methods on a different species (mice) to measure their generalizability. Both methods experimentally resulted in good signal recovery performance, but only the images super-resolved by BiDA were accurately skullstripped downstream. Although both methods performed well on the in-domain rat data, BiDA did not fully generalize to the out-of-domain mouse data.