Viviana de Luca
Research Subjects
Research Interests
Viviana de Luca has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alberto Catena
STMicroelectronics, SIC Campus, Via Passo Martino, SP69, 95121 Catania, CT, Italy
1 shared publication - Björn Magnusson
STMicroelectronics Silicon Carbide AB
1 shared publication - Gennadi Polisski
Semilab
1 shared publication - Jimmy Thörnberg
STMicroelectronics
1 shared publication - Marshall Wilson
Semilab SDI
1 shared publication - Stella Giuffrida
STMicroelectronics Silicon Carbide AB
1 shared publication
Latest Publications
- Open Access
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 19-26
Coherency between Epitaxial Defectivity, Surface Voltage, Photoluminescence Mapping and Electrical Wafer Sorting for 200mm SiC Wafers
Electrical Wafer Sorting (EWS) on 12 000, 650 V SiC MOSFETs devices from 7 wafers of 200 mm 4H-SiC are compared with electrical deviations and defectivity of initial epitaxial layers measured using Charge biased non-Contact Voltage imaging, QUAD (Quality Uniformity And Defects), and optical surface detection with PL-imaging, respectively. We successfully demonstrate an increased prediction rate in both KR (kill-ratio) and YI (yield-impact) compared to conventional PL-imaging. It is also shown that QUAD not only supplements PL-imaging but supersedes it predicting failure in some electrical test conditions. We therefore show that the combination of QUAD and PL-imaging results significantly improves the accuracy of device failure prediction by uniquely locating faults in the wafers, and thus, improving foresight of successful device fabrication.
- 10 September 2025
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 376, 19-26
Open AccessCoherency between Epitaxial Defectivity, Surface Voltage, Photoluminescence Mapping and Electrical Wafer Sorting for 200mm SiC Wafers
Electrical Wafer Sorting (EWS) on 12 000, 650 V SiC MOSFETs devices from 7 wafers of 200 mm 4H-SiC are compared with electrical deviations and defectivity of initial epitaxial layers measured using Charge biased non-Contact Voltage imaging, QUAD (Quality Uniformity And Defects), and optical surface detection with PL-imaging, respectively. We successfully demonstrate an increased prediction rate in both KR (kill-ratio) and YI (yield-impact) compared to conventional PL-imaging. It is also shown that QUAD not only supplements PL-imaging but supersedes it predicting failure in some electrical test conditions. We therefore show that the combination of QUAD and PL-imaging results significantly improves the accuracy of device failure prediction by uniquely locating faults in the wafers, and thus, improving foresight of successful device fabrication.