Rebecca Gerber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rebecca Gerber has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- A. Redey
School of Engineering Science and the Nuclear Science Laboratory, Simon Fraser University, Burnaby, BC, Canada
2 shared publications - A. Woinoski
Department of Physics, Simon Fraser University, Burnaby, BC, Canada
2 shared publications - H. Asch
Department of Physics, Simon Fraser University, Burnaby, BC, Canada
2 shared publications - Krzysztof Starosta
Simon Fraser University
2 shared publications - Z. Yu
Simon Fraser University
2 shared publications - Avneet Bhuller
Department of Chemistry Simon Fraser University Burnaby British Columbia Canada
1 shared publication
Latest Publications
- Open Access
- 20 August 2026
- Published by Wiley in ChemCatChem
- Vol. 18 (16) , e71024
Potential‐ and pH‐Dependent Surface Oxidation of Niobium Nitride for the Oxygen Reduction Reaction: A DFT Study
Transition metal nitrides (TMNs) are promising oxygen reduction reaction (ORR) catalysts owing to their high conductivity, stability, and earth abundance. However, active TMN catalysts are often identified using conventional ORR descriptors that neglect the catalyst resting state. Here, we investigate the ORR performance of 14 TMNs using density functional theory (DFT) calculations and conventional *OH/*OOH descriptors. Although these descriptors identify several promising candidates, most TMNs bind oxygen too strongly, causing conventional activity predictions to fail. Using Nb 4 N 5 (100) as a model system, we construct surface phase and Pourbaix diagrams to identify the relevant surface state as a function of potential and pH. Nb 4 N 5 (100) becomes increasingly oxygen‐covered above 0.40 V under acidic conditions, with oxidation occurring at lower potentials as pH increases. Oxygen‐covered surfaces alter ORR energetics and favor a dissociative pathway, challenging the commonly assumed associative mechanism. Despite accounting for surface oxidation, Nb 4 N 5 (100) remains a poor ORR catalyst because it excessivly stabilizes oxygenated intermediates. These findings demonstrate that realistic surface states must be considered alongside conventional descriptors when evaluating ORR catalysts.
- 20 August 2026
- Published by Wiley in ChemCatChem
- Vol. 18 (16) , e71024
Open AccessPotential‐ and pH‐Dependent Surface Oxidation of Niobium Nitride for the Oxygen Reduction Reaction: A DFT Study
Transition metal nitrides (TMNs) are promising oxygen reduction reaction (ORR) catalysts owing to their high conductivity, stability, and earth abundance. However, active TMN catalysts are often identified using conventional ORR descriptors that neglect the catalyst resting state. Here, we investigate the ORR performance of 14 TMNs using density functional theory (DFT) calculations and conventional *OH/*OOH descriptors. Although these descriptors identify several promising candidates, most TMNs bind oxygen too strongly, causing conventional activity predictions to fail. Using Nb 4 N 5 (100) as a model system, we construct surface phase and Pourbaix diagrams to identify the relevant surface state as a function of potential and pH. Nb 4 N 5 (100) becomes increasingly oxygen‐covered above 0.40 V under acidic conditions, with oxidation occurring at lower potentials as pH increases. Oxygen‐covered surfaces alter ORR energetics and favor a dissociative pathway, challenging the commonly assumed associative mechanism. Despite accounting for surface oxidation, Nb 4 N 5 (100) remains a poor ORR catalyst because it excessivly stabilizes oxygenated intermediates. These findings demonstrate that realistic surface states must be considered alongside conventional descriptors when evaluating ORR catalysts.
- Open Access
- 24 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Novel application of the 8 π gamma-ray spectrometer for 3 γ positron emission tomography
- 24 November 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Open AccessNovel application of the 8 π gamma-ray spectrometer for 3 γ positron emission tomography
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (9) , 3102-3108
A Versatile Digital Data Acquisition System for the 8π Gamma-Ray Spectrometer
The 8π gamma-ray spectrometer is a highly-efficient and selective ball array of Bismuth Germanium Oxide (BGO) detectors. In 2014, it was relocated from TRIUMF, Canada’s particle accelerator centre, to the Simon Fraser University Nuclear Science Laboratory, where it has been recommissioned with upgraded components for rare decay spectroscopy. In its current configuration, 8π has 12 BGO pentagon detectors and 60 BGO hexagon detectors arranged in an icosahedral symmetry. Together, they provide 132 readout channels and approximately 95% solid-angle coverage. A unique digital Data Acquisition System (DAQ) has been developed around the existing 8π BGO detectors for the study of rare decays. This system allows for the fine-tuning of logic and digitization parameters through a web interface, eliminating the need for physical reconfiguration and providing a level of flexibility not previously offered. This upgraded DAQ system includes three synchronized VF48 digitizers for waveform digitization, two XLM72S modules for online multiplicity filtering, and additional components for thresholding and pile-up handling functionality. Performance metrics such as energy resolution, timing resolution, and efficiency were measured, demonstrating the functionality of all 8π subsystems. The spectrometer is fully prepared for experiments demanding efficient and selective time-resolved gamma-ray spectroscopy. Designed with future expansion in mind, the 8π can easily support additional detectors, making it well-suited for a wide range of future experiments.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (9) , 3102-3108
A Versatile Digital Data Acquisition System for the 8π Gamma-Ray Spectrometer
The 8π gamma-ray spectrometer is a highly-efficient and selective ball array of Bismuth Germanium Oxide (BGO) detectors. In 2014, it was relocated from TRIUMF, Canada’s particle accelerator centre, to the Simon Fraser University Nuclear Science Laboratory, where it has been recommissioned with upgraded components for rare decay spectroscopy. In its current configuration, 8π has 12 BGO pentagon detectors and 60 BGO hexagon detectors arranged in an icosahedral symmetry. Together, they provide 132 readout channels and approximately 95% solid-angle coverage. A unique digital Data Acquisition System (DAQ) has been developed around the existing 8π BGO detectors for the study of rare decays. This system allows for the fine-tuning of logic and digitization parameters through a web interface, eliminating the need for physical reconfiguration and providing a level of flexibility not previously offered. This upgraded DAQ system includes three synchronized VF48 digitizers for waveform digitization, two XLM72S modules for online multiplicity filtering, and additional components for thresholding and pile-up handling functionality. Performance metrics such as energy resolution, timing resolution, and efficiency were measured, demonstrating the functionality of all 8π subsystems. The spectrometer is fully prepared for experiments demanding efficient and selective time-resolved gamma-ray spectroscopy. Designed with future expansion in mind, the 8π can easily support additional detectors, making it well-suited for a wide range of future experiments.