Rémy Coulomb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rémy Coulomb has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Pascal Kouyoumdjian
Centre Hospitalier Universitaire de Nîmes, Nîmes, France
5 shared publications - Youssef Jamaleddine
Department of Orthopedic Surgery, Lebanese American University Medical Center‐Rizk Hospital, Beirut, Lebanon
5 shared publications - Thomas Grosso
Centre Hospitalier Universitaire de Nîmes, Nîmes, France
2 shared publications - Ahmad Haj Hussein
Lebanese American University Medical Center‐Rizk Hospital, Beirut, Lebanon
1 shared publication - Daniel Donici
Centre Hospitalier Universitaire de Nîmes, Nîmes, France
1 shared publication - Emeline Chapron
Department of orthopedic Surgery, Centre Hospitalier Universitaire de Nîmes, Nîmes, France
1 shared publication
Latest Publications
- 21 July 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (11) , 2847-2853
High pelvic incidence is associated with inferior one-year outcomes after hip arthroscopy for femoroacetabular impingement: a multicentre study with spinopelvic analysis
- 21 July 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (11) , 2847-2853
High pelvic incidence is associated with inferior one-year outcomes after hip arthroscopy for femoroacetabular impingement: a multicentre study with spinopelvic analysis
- 21 January 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 537-538
Authors’ Reply to the Letter to the editor on “CT-based three-dimensional planning predicts cup size with near-perfect accuracy in robotic total hip arthroplasty”
- 21 January 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 537-538
Authors’ Reply to the Letter to the editor on “CT-based three-dimensional planning predicts cup size with near-perfect accuracy in robotic total hip arthroplasty”
- 5 January 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 469-477
Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement
Background Modular dual mobility (MDM) cups are widely used in primary total hip arthroplasty (THA) to reduce dislocation, but their impact on range of motion (ROM) to impingement versus single-mobility (SM) cups remains uncertain. Methods In this paired robotic-simulation study, 108 primary robotic-assisted THAs were virtually planned twice with CT-based software, once with an SM cup and once with an MDM cup. Cup and stem orientation were optimised to restore intra-articular length and global offset within 5 mm of the contralateral hip and to avoid impingement. ROM to first impingement was measured in extension/external rotation (ER), flexion/internal rotation (IR) with physiological pelvic tilt, and flexion/IR with 20° adduction. The mode of first impingement (intra-articular, extra-articular, or mixed) was recorded. Results Compared with SM, MDM cups increased ROM to impingement in extension and ER but slightly reduced ROM in flexion and IR at several test positions. Maximal extension to impingement and ER in extension were higher with MDM, whereas flexion with pelvic anteversion and IR at 100° flexion were lower. ROM to impingement was not uniformly greater with MDM, and first contact often shifted from intra-articular implant-on-implant impingement toward extra-articular impingement. Conclusion In robotic THA, MDM cups provide selective gains in ROM to impingement and shift the impingement towards extra-articular structures rather than providing a global increase in safe ROM. Clinically, MDM may suit patients needing extension/ER reserve or with anterior instability risk, and planning should consider osteophytes and bony constraints. Further prospective clinical validation is warranted.
- 5 January 2026
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 469-477
Beyond jump distance: modular dual mobility versus single mobility cups in robotic total hip arthroplasty - simulation of hip kinematics and impingement
Background Modular dual mobility (MDM) cups are widely used in primary total hip arthroplasty (THA) to reduce dislocation, but their impact on range of motion (ROM) to impingement versus single-mobility (SM) cups remains uncertain. Methods In this paired robotic-simulation study, 108 primary robotic-assisted THAs were virtually planned twice with CT-based software, once with an SM cup and once with an MDM cup. Cup and stem orientation were optimised to restore intra-articular length and global offset within 5 mm of the contralateral hip and to avoid impingement. ROM to first impingement was measured in extension/external rotation (ER), flexion/internal rotation (IR) with physiological pelvic tilt, and flexion/IR with 20° adduction. The mode of first impingement (intra-articular, extra-articular, or mixed) was recorded. Results Compared with SM, MDM cups increased ROM to impingement in extension and ER but slightly reduced ROM in flexion and IR at several test positions. Maximal extension to impingement and ER in extension were higher with MDM, whereas flexion with pelvic anteversion and IR at 100° flexion were lower. ROM to impingement was not uniformly greater with MDM, and first contact often shifted from intra-articular implant-on-implant impingement toward extra-articular impingement. Conclusion In robotic THA, MDM cups provide selective gains in ROM to impingement and shift the impingement towards extra-articular structures rather than providing a global increase in safe ROM. Clinically, MDM may suit patients needing extension/ER reserve or with anterior instability risk, and planning should consider osteophytes and bony constraints. Further prospective clinical validation is warranted.
- 27 November 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 411-417
Computerised Tomography based three dimensional planning predicts cup size with near-perfect accuracy in robotic total hip arthroplasty: a study of six hundred and nineteen hips
Introduction Accurate cup sizing is crucial in total hip arthroplasty (THA). Conventional templating and intra-operative head sizing show inconsistent accuracy, whereas CT-based planning in robotic-assisted THA may offer superior precision. We aimed to compare implanted cup size with both CT-based planning and intra-operative native head sizing, hypothesising that CT planning would provides greater accuracy and consistency. Methods This single-centre study included 619 consecutive robot-assisted primary THAs templated with pre-operative CT scans. Implanted cup size was compared with the pre-operative CT-planned size in all hips, and with the intra-operative measurement of the native femoral head in 299 hips. Results : CT-based planning closely predicted the implanted cup (exact 94.3%; ±1 size 98.7%; mean difference 0.05 ± 0.67 mm; r = 0.984, p < 0.001). Implant–native head comparisons showed larger mismatches (3.14 ± 2.31 mm; exact 9.4%; ±1 size 40.5%; r = 0.817, p < 0.001). Plan-implant agreement was modestly better in females (p = 0.039) and in smaller head categories (< 50 and 50–54 mm) versus > 54 mm (p = 0.007). For implant versus head, mismatch magnitude varied by head size, smaller heads tended toward greater relative oversizing, without a sex effect (p = 0.76). Conclusion In robotic THA, CT-based 3-D planning provides near-perfect cup-size prediction and substantially outperforms using the native head as a sizing reference. Residual variation reflects patient-specific factors, chiefly native head size and, to a lesser extent, sex, which should be considered alongside the CT plan. Using native head diameter as a complementary check may further refine pre-operative algorithms and guide intra-operative choices, optimizing component selection for long-term stability and function.
- 27 November 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 411-417
Computerised Tomography based three dimensional planning predicts cup size with near-perfect accuracy in robotic total hip arthroplasty: a study of six hundred and nineteen hips
Introduction Accurate cup sizing is crucial in total hip arthroplasty (THA). Conventional templating and intra-operative head sizing show inconsistent accuracy, whereas CT-based planning in robotic-assisted THA may offer superior precision. We aimed to compare implanted cup size with both CT-based planning and intra-operative native head sizing, hypothesising that CT planning would provides greater accuracy and consistency. Methods This single-centre study included 619 consecutive robot-assisted primary THAs templated with pre-operative CT scans. Implanted cup size was compared with the pre-operative CT-planned size in all hips, and with the intra-operative measurement of the native femoral head in 299 hips. Results : CT-based planning closely predicted the implanted cup (exact 94.3%; ±1 size 98.7%; mean difference 0.05 ± 0.67 mm; r = 0.984, p < 0.001). Implant–native head comparisons showed larger mismatches (3.14 ± 2.31 mm; exact 9.4%; ±1 size 40.5%; r = 0.817, p < 0.001). Plan-implant agreement was modestly better in females (p = 0.039) and in smaller head categories (< 50 and 50–54 mm) versus > 54 mm (p = 0.007). For implant versus head, mismatch magnitude varied by head size, smaller heads tended toward greater relative oversizing, without a sex effect (p = 0.76). Conclusion In robotic THA, CT-based 3-D planning provides near-perfect cup-size prediction and substantially outperforms using the native head as a sizing reference. Residual variation reflects patient-specific factors, chiefly native head size and, to a lesser extent, sex, which should be considered alongside the CT plan. Using native head diameter as a complementary check may further refine pre-operative algorithms and guide intra-operative choices, optimizing component selection for long-term stability and function.
- 23 September 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (11) , 2615-2623
Does three-dimensional planning of anterior acetabular component overhang affect short-term functional outcomes after robotic-assisted total hip arthroplasty?
Purpose Three-dimensional robotic planning may oblige the surgeon to accept an anterior overhang of the acetabular cup. Whether this planned overhang compromises short-term outcomes is unknown. Methods We retrospectively reviewed 437 consecutive robotic total hip arthroplasties (THA) performed between November 2018 and March 2022; 192 hips with complete 3-D screenshots and 12-month follow-up formed the study cohort. Anterior overhang on the definitive plan was graded minor (≤ 2 mm), moderate (between 2 and 4 mm), or major (≥ 4 mm). Primary outcome was psoas pain at one year, defined by pain on resisted-hip-flexion testing; psoas impingement was confirmed if infiltration or tenotomy was performed. Secondary endpoints were Harris Hip Score (HHS), Oxford Hip Score (OHS) and Forgotten Joint Score (FJS-12). Results Planned overhang occurred in 52 of 192 hips (27%): 33 minor, 18 moderate and one major. Psoas pain was more frequent with overhang (16% vs. 3.8%; p = 0.008); no differences were recorded for confirmed psoas impingement, groin pain, re-operation or revision of implants. Differences of mean HHS, OHS and FJS-12 at three and twelve months were non-significant between groups. Anterior wall index < 0.33, lateral center-edge angle < 25° and female sex are associated with overhang. Conclusions Minor anterior cup overhang is common in robotic THA. It increases the likelihood of clinical psoas impingement but does not impair early hip function or raise revision risk. Accepting minor overhang is clinically acceptable when necessary, provided patients are counselled about increased psoas pain risk and high-risk anatomies are monitored.
- 23 September 2025
- Published by Springer Nature in International Orthopaedics
- Vol. 49 (11) , 2615-2623
Does three-dimensional planning of anterior acetabular component overhang affect short-term functional outcomes after robotic-assisted total hip arthroplasty?
Purpose Three-dimensional robotic planning may oblige the surgeon to accept an anterior overhang of the acetabular cup. Whether this planned overhang compromises short-term outcomes is unknown. Methods We retrospectively reviewed 437 consecutive robotic total hip arthroplasties (THA) performed between November 2018 and March 2022; 192 hips with complete 3-D screenshots and 12-month follow-up formed the study cohort. Anterior overhang on the definitive plan was graded minor (≤ 2 mm), moderate (between 2 and 4 mm), or major (≥ 4 mm). Primary outcome was psoas pain at one year, defined by pain on resisted-hip-flexion testing; psoas impingement was confirmed if infiltration or tenotomy was performed. Secondary endpoints were Harris Hip Score (HHS), Oxford Hip Score (OHS) and Forgotten Joint Score (FJS-12). Results Planned overhang occurred in 52 of 192 hips (27%): 33 minor, 18 moderate and one major. Psoas pain was more frequent with overhang (16% vs. 3.8%; p = 0.008); no differences were recorded for confirmed psoas impingement, groin pain, re-operation or revision of implants. Differences of mean HHS, OHS and FJS-12 at three and twelve months were non-significant between groups. Anterior wall index < 0.33, lateral center-edge angle < 25° and female sex are associated with overhang. Conclusions Minor anterior cup overhang is common in robotic THA. It increases the likelihood of clinical psoas impingement but does not impair early hip function or raise revision risk. Accepting minor overhang is clinically acceptable when necessary, provided patients are counselled about increased psoas pain risk and high-risk anatomies are monitored.