Computerised Tomography based three dimensional planning predicts cup size with near-perfect accuracy in robotic total hip arthroplasty: a study of six hundred and nineteen hips
- 27 November 2025
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 50 (2) , 411-417
Abstract
Introduction Accurate cup sizing is crucial in total hip arthroplasty (THA). Conventional templating and intra-operative head sizing show inconsistent accuracy, whereas CT-based planning in robotic-assisted THA may offer superior precision. We aimed to compare implanted cup size with both CT-based planning and intra-operative native head sizing, hypothesising that CT planning would provides greater accuracy and consistency. Methods This single-centre study included 619 consecutive robot-assisted primary THAs templated with pre-operative CT scans. Implanted cup size was compared with the pre-operative CT-planned size in all hips, and with the intra-operative measurement of the native femoral head in 299 hips. Results : CT-based planning closely predicted the implanted cup (exact 94.3%; ±1 size 98.7%; mean difference 0.05 ± 0.67 mm; r = 0.984, p < 0.001). Implant–native head comparisons showed larger mismatches (3.14 ± 2.31 mm; exact 9.4%; ±1 size 40.5%; r = 0.817, p < 0.001). Plan-implant agreement was modestly better in females (p = 0.039) and in smaller head categories (< 50 and 50–54 mm) versus > 54 mm (p = 0.007). For implant versus head, mismatch magnitude varied by head size, smaller heads tended toward greater relative oversizing, without a sex effect (p = 0.76). Conclusion In robotic THA, CT-based 3-D planning provides near-perfect cup-size prediction and substantially outperforms using the native head as a sizing reference. Residual variation reflects patient-specific factors, chiefly native head size and, to a lesser extent, sex, which should be considered alongside the CT plan. Using native head diameter as a complementary check may further refine pre-operative algorithms and guide intra-operative choices, optimizing component selection for long-term stability and function.Keywords
This publication has 18 references indexed in Scilit:
- Validation of CT‐Based Three‐Dimensional Preoperative Planning in Comparison with Acetate Templating for Primary Total Hip ArthroplastyOrthopaedic Surgery, 2022
- Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its ValidationIndian Journal of Orthopaedics, 2020
- Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysisInternational Orthopaedics, 2016
- Measuring the Femoral Head Size — An Additional Real-Time Intraoperative Monitoring Tool for the Accuracy of the Preoperative Process and Implant SelectionThe Journal of Arthroplasty, 2015
- Acetate Templating on Digital Images Is More Accurate Than Computer-based Templating for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2015
- Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographsJournal of Clinical Orthopaedics and Trauma, 2015
- A Comparison of Acetate and Digital Templating for Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2007
- The utility and precision of analogue and digital preoperative planning for total hip arthroplastyInternational Orthopaedics, 2007
- An AOA Critical Issue The Outcome of the Outcomes Movement*Journal of Bone and Joint Surgery, 2004
- Determination of accuracy of preoperative templating of noncemented femoral prosthesesThe Journal of Arthroplasty, 1995