Edson Caoru Kitani
Research Subjects
Edson Caoru Kitani has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- André de Souza Mendes
FEI University Center, So Bernardo do Campo, Brazil
1 shared publication - Bartira de Aguiar Roza
Universidade Federal de São Paulo
1 shared publication - Cirilo De Paula Silva
Escola Politcnica da Universidade de So Paulo, So Paulo, Brazil
1 shared publication - Fabrizio Leonardi
FEI University Center, So Bernardo do Campo, Brazil
1 shared publication - Flavio Pola dos Reis
Instituto do Coracao, Hospital das Clinicas HCFMUSP, Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, Brazil
1 shared publication - Leopoldo Rideki Yoshioka
Escola Politcnica, Universidade de So Paulo, So Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 144 (4)
Validation of the thermal stability of EMAIS-SR autonomous packaging for preservation of porcine lungs: cooling curve in an experimental model
BACKGROUND: Intermediate temperatures (10°C) better preserve mitochondrial function and extend ischemic time, which are fundamental for lung preservation during transplantation. The EMAIS-SR device was developed as a reusable, cost-effective alternative to maintain the 10°C set-point, thereby overcoming logistical and economic barriers in organ transport. OBJECTIVE: This study aimed to validate the thermal stability of the EMAIS-SR system in a swine model by evaluating the organ-cooling curve and the time spent within the target temperature range. DESIGN AND SETTING: Validation study using experimental surgery on porcine organs. METHODS: Lung blocks were harvested from two Landrace swine in independent experiments (P1, P2). The organs were placed in triple sterile packaging. Thermal stability was monitored for 48 h by using four negative temperature coefficient (NTC) thermistors (three intrapulmonary and one extrapulmonary) with data acquisition at a 0.1-s interval. Another datalogger (Hantek ® HTM208B) was used for control and validation. Thermal distribution was further characterized by infrared thermography (FLIR C3-X). RESULTS: In Experiment 1 (P1), intrapulmonary temperatures reached the predefined target range (≤ 12°C) approximately 1.4 h after lung extraction, and the mean temperature recorded in the container was 8.01 °C (standard deviation, 2.88°C). In Experiment 2 (P2), a mean temperature reduction of 6.6°C was observed, bringing the intrapulmonary temperature to the target range (≤ 12°C) within approximately 2 h post-extraction. CONCLUSION: The EMAIS-SR device effectively maintained lung-preservation temperatures within the target 8°C–12°C range over 48 h. These results demonstrate the system’s technical feasibility and its capacity to provide consistent thermal stability across intrapulmonary compartments.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 144 (4)
Open AccessValidation of the thermal stability of EMAIS-SR autonomous packaging for preservation of porcine lungs: cooling curve in an experimental model
BACKGROUND: Intermediate temperatures (10°C) better preserve mitochondrial function and extend ischemic time, which are fundamental for lung preservation during transplantation. The EMAIS-SR device was developed as a reusable, cost-effective alternative to maintain the 10°C set-point, thereby overcoming logistical and economic barriers in organ transport. OBJECTIVE: This study aimed to validate the thermal stability of the EMAIS-SR system in a swine model by evaluating the organ-cooling curve and the time spent within the target temperature range. DESIGN AND SETTING: Validation study using experimental surgery on porcine organs. METHODS: Lung blocks were harvested from two Landrace swine in independent experiments (P1, P2). The organs were placed in triple sterile packaging. Thermal stability was monitored for 48 h by using four negative temperature coefficient (NTC) thermistors (three intrapulmonary and one extrapulmonary) with data acquisition at a 0.1-s interval. Another datalogger (Hantek ® HTM208B) was used for control and validation. Thermal distribution was further characterized by infrared thermography (FLIR C3-X). RESULTS: In Experiment 1 (P1), intrapulmonary temperatures reached the predefined target range (≤ 12°C) approximately 1.4 h after lung extraction, and the mean temperature recorded in the container was 8.01 °C (standard deviation, 2.88°C). In Experiment 2 (P2), a mean temperature reduction of 6.6°C was observed, bringing the intrapulmonary temperature to the target range (≤ 12°C) within approximately 2 h post-extraction. CONCLUSION: The EMAIS-SR device effectively maintained lung-preservation temperatures within the target 8°C–12°C range over 48 h. These results demonstrate the system’s technical feasibility and its capacity to provide consistent thermal stability across intrapulmonary compartments.
- Open Access
- 9 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 158660-158678
Design and Experimental Validation of Modular Autonomous Driving Platform for Off-Road 8 × 4 Trucks in Agricultural Operation
This study introduces and experimentally validates an autonomous driving platform for off-road $8\times 4$ heavy-duty trucks, aimed at sugarcane harvesting operations. The system integrates a minimally invasive drive-by-wire interface for throttle, braking, and steering; a GNSS-based localization module; and a lightweight perception suite comprising a 2D LiDAR and a monocular camera. A modular ROS2-based architecture supports real-time perception, planning, and control. The platform was tested on an off-road track in Brazil across eight driving scenarios, including straight paths, curves, and obstacle avoidance at varying speeds. A spatial evaluation framework was implemented using arc-length reparameterization and KD-Tree nearest-neighbor matching to compare actual and reference trajectories. Metrics included lateral and heading RMSE, IAE, ITAE, jerk, and obstacle clearance. Results showed consistent high lateral tracking accuracy, with RMSE reaching 0.15 m in straight segments and remaining below 1.0 m in most complex scenarios. Scenario T8, involving curvature and obstacle deviation, surpassed this threshold due to increased control demands. Across 40 runs, heading RMSE remained below 10°, obstacle clearance above 1.5 m, and jerk below 0.5 m/s3. Geometrically modeled references yielded more stable heading control, while manually recorded paths resulted in smoother dynamic profiles. Statistical analysis confirmed that increased trajectory complexity degrades performance. Scenario T6 outperformed others in lateral stability, though results were statistically like T1 under simpler conditions. The platform demonstrated reliable tracking and real-time operation in scenarios representative of off-road agricultural tasks. Future work will focus on mitigating GNSS latency, improving post-obstacle recovery, and integrating sensor redundancy and adaptive planning to enhance deployment in agricultural logistics.
- 9 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 158660-158678
Open AccessDesign and Experimental Validation of Modular Autonomous Driving Platform for Off-Road 8 × 4 Trucks in Agricultural Operation
This study introduces and experimentally validates an autonomous driving platform for off-road $8\times 4$ heavy-duty trucks, aimed at sugarcane harvesting operations. The system integrates a minimally invasive drive-by-wire interface for throttle, braking, and steering; a GNSS-based localization module; and a lightweight perception suite comprising a 2D LiDAR and a monocular camera. A modular ROS2-based architecture supports real-time perception, planning, and control. The platform was tested on an off-road track in Brazil across eight driving scenarios, including straight paths, curves, and obstacle avoidance at varying speeds. A spatial evaluation framework was implemented using arc-length reparameterization and KD-Tree nearest-neighbor matching to compare actual and reference trajectories. Metrics included lateral and heading RMSE, IAE, ITAE, jerk, and obstacle clearance. Results showed consistent high lateral tracking accuracy, with RMSE reaching 0.15 m in straight segments and remaining below 1.0 m in most complex scenarios. Scenario T8, involving curvature and obstacle deviation, surpassed this threshold due to increased control demands. Across 40 runs, heading RMSE remained below 10°, obstacle clearance above 1.5 m, and jerk below 0.5 m/s3. Geometrically modeled references yielded more stable heading control, while manually recorded paths resulted in smoother dynamic profiles. Statistical analysis confirmed that increased trajectory complexity degrades performance. Scenario T6 outperformed others in lateral stability, though results were statistically like T1 under simpler conditions. The platform demonstrated reliable tracking and real-time operation in scenarios representative of off-road agricultural tasks. Future work will focus on mitigating GNSS latency, improving post-obstacle recovery, and integrating sensor redundancy and adaptive planning to enhance deployment in agricultural logistics.