Meiru Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Meiru Guo has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Dongshan Lian
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Jingzhi Huang
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Runze Yang
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Shouru Gao
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Yongmeng Liu
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Jiean Li
Center of Ultra-Precision Optoelectronic Instrument Engineering and the Key Laboratory of Ultra-Precision Intelligent Instrumentation Engineering, Harbin Institute of Technology, Harbin, China
1 shared publication
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Measurement Approach for Radius Gauge Based on Telecentric Backlight Projection
As an important gauge for measuring incomplete arc components in aero-engines, the measurement accuracy of standard radius gauges is crucial. To improve the accuracy and efficiency of radius gauge with short arc contour, this paper proposes a radius gauge arc contour dimension measurement approach based on telecentric backlight projection. A radius gauge arc contour dimension measurement system is designed, and projection images of the measured radius gauges are captured using an area scan camera equipped with a bilateral telecentric lens. A systematic calibration method is introduced to determine the coordinate transformation parameters, lens distortion parameters, and camera installation tilt angle. These calibrated parameters are used to compensate the arc profile image coordinates. Additionally,to address the issue of low arc fitting accuracy for small central angles in traditional arc fitting algorithms, an improved Kasa arc fitting algorithm based on the Huber loss function is proposed, which is used to fit and obtain the curvature radius of the radius gauge. Numerical simulations were conducted to validate the accuracy of the proposed algorithm. The proposed method was applied to measure a standard ring gauge with a reference radius of 10.000 mm, yielding a measured radius of 10.001 mm with a standard deviation of 0.001 mm. Eight different standard radius gauges were also measured, and the measurement deviations of all the tested radius gauges were within 0.02 mm, with standard deviations less than 0.003 mm. The proposed measurement approach can be extended to the radius parameter measurement of other components containing incomplete arcs.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
A Measurement Approach for Radius Gauge Based on Telecentric Backlight Projection
As an important gauge for measuring incomplete arc components in aero-engines, the measurement accuracy of standard radius gauges is crucial. To improve the accuracy and efficiency of radius gauge with short arc contour, this paper proposes a radius gauge arc contour dimension measurement approach based on telecentric backlight projection. A radius gauge arc contour dimension measurement system is designed, and projection images of the measured radius gauges are captured using an area scan camera equipped with a bilateral telecentric lens. A systematic calibration method is introduced to determine the coordinate transformation parameters, lens distortion parameters, and camera installation tilt angle. These calibrated parameters are used to compensate the arc profile image coordinates. Additionally,to address the issue of low arc fitting accuracy for small central angles in traditional arc fitting algorithms, an improved Kasa arc fitting algorithm based on the Huber loss function is proposed, which is used to fit and obtain the curvature radius of the radius gauge. Numerical simulations were conducted to validate the accuracy of the proposed algorithm. The proposed method was applied to measure a standard ring gauge with a reference radius of 10.000 mm, yielding a measured radius of 10.001 mm with a standard deviation of 0.001 mm. Eight different standard radius gauges were also measured, and the measurement deviations of all the tested radius gauges were within 0.02 mm, with standard deviations less than 0.003 mm. The proposed measurement approach can be extended to the radius parameter measurement of other components containing incomplete arcs.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Telecentric Imaging-Based Dimensional Measurement for Rotational Components With Magnification and Edge Localization Error Correction
To ensure high accuracy in measuring the diameters of rotational components, this study presents a measurement method based on a telecentric imaging system with magnification and edge localization error correction. A rotational component diameter measurement system is designed, where projection images of the axial cross section of the measured component are captured using an area-scan camera equipped with a bilateral telecentric lens. A calibration method involving both a standard sphere and a pin gauge is proposed to accurately correct magnification and edge localization errors of the system. The diameter measurement results are then obtained by incorporating these error corrections. The effectiveness of the proposed method is demonstrated by measuring two pin gauges with diameters of 12.5 and 7.5 mm, as well as a 20-mm steel ball. Compared to the precalibration results, the measurement error decreased by 0.0350, 0.0424, and 0.0332 mm. In addition, compared with the checkerboard calibration method, the proposed method demonstrated an error reduction of 0.0006, 0.0012, and 0.0024 mm. The proposed method can be extended to telecentric optical imaging measurements for other geometric parameters.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Telecentric Imaging-Based Dimensional Measurement for Rotational Components With Magnification and Edge Localization Error Correction
To ensure high accuracy in measuring the diameters of rotational components, this study presents a measurement method based on a telecentric imaging system with magnification and edge localization error correction. A rotational component diameter measurement system is designed, where projection images of the axial cross section of the measured component are captured using an area-scan camera equipped with a bilateral telecentric lens. A calibration method involving both a standard sphere and a pin gauge is proposed to accurately correct magnification and edge localization errors of the system. The diameter measurement results are then obtained by incorporating these error corrections. The effectiveness of the proposed method is demonstrated by measuring two pin gauges with diameters of 12.5 and 7.5 mm, as well as a 20-mm steel ball. Compared to the precalibration results, the measurement error decreased by 0.0350, 0.0424, and 0.0332 mm. In addition, compared with the checkerboard calibration method, the proposed method demonstrated an error reduction of 0.0006, 0.0012, and 0.0024 mm. The proposed method can be extended to telecentric optical imaging measurements for other geometric parameters.