Donghao Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Donghao Xie has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yinbao Cheng
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China
4 shared publications Bin Shen
Hangzhou Optical-Ruler Technology Co., Ltd, Hangzhou, People’s Republic of China
1 shared publication- Bo Tang
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China
1 shared publication - Hongli Li
Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Opto-Electronics Engineering, Hefei University of Technology, Hefei, Anhui, China
1 shared publication - Huan Liu
Zhoushan Institute of Calibration and Testing for Quality and Technology Supervision, Zhoushan 316000, China
1 shared publication - Jianghuan Shi
Ningbo Institute of Metrology and Testing, Ningbo 315048, China
1 shared publication
Latest Publications
- Open Access
- 19 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (9) , 209
Calibration Method and Uncertainty Evaluation for X-Ray Fluorescence Chlorine Analyzers
X-ray fluorescence (XRF) chlorine analyzers are widely used for chlorine determination in crude oil and petroleum products. Although analytical test procedures are standardized, a calibration-oriented uncertainty framework for the analyzer itself remains insufficiently developed. This study establishes a metrological framework for relative indication error and limit of detection (LOD), supported by repeatability and linearity evaluations, and compares uncertainty propagation using the Guide to the Expression of Uncertainty in Measurement (GUM) and the Monte Carlo method (MCM). For relative indication error, residual matrix mismatch was quantified using paired isooctane-based light-oil and 75 cSt mineral-oil reference materials and incorporated with measurement repeatability and certified-value uncertainty. At 100, 300 and 500 mg/L, GUM and MCM produced closely agreeing standard uncertainties of approximately 0.0115, 0.0103 and 0.0081, respectively. For LOD, both methods used the same dual-axis error-weighted regression, accounting for uncertainties in certified concentrations and mean instrumental responses; in the MCM, the regression was repeated for every simulated calibration data set. The resulting standard uncertainties were 0.0048 mg/L (GUM) and 0.0047 mg/L (MCM), and the MCM equal-tailed 95% coverage interval was 0.0122–0.0307 mg/L. The framework’s distinctive value is the consistent treatment of calibration measurands, matrix transfer and dual-axis error-weighted regression across both propagation methods. It provides an auditable GUM budget for routine calibration and certificate reporting, while MCM offers a verification route when repeated regression, finite-sample blank dispersion or asymmetric output intervals are important.
- 19 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (9) , 209
Open AccessCalibration Method and Uncertainty Evaluation for X-Ray Fluorescence Chlorine Analyzers
X-ray fluorescence (XRF) chlorine analyzers are widely used for chlorine determination in crude oil and petroleum products. Although analytical test procedures are standardized, a calibration-oriented uncertainty framework for the analyzer itself remains insufficiently developed. This study establishes a metrological framework for relative indication error and limit of detection (LOD), supported by repeatability and linearity evaluations, and compares uncertainty propagation using the Guide to the Expression of Uncertainty in Measurement (GUM) and the Monte Carlo method (MCM). For relative indication error, residual matrix mismatch was quantified using paired isooctane-based light-oil and 75 cSt mineral-oil reference materials and incorporated with measurement repeatability and certified-value uncertainty. At 100, 300 and 500 mg/L, GUM and MCM produced closely agreeing standard uncertainties of approximately 0.0115, 0.0103 and 0.0081, respectively. For LOD, both methods used the same dual-axis error-weighted regression, accounting for uncertainties in certified concentrations and mean instrumental responses; in the MCM, the regression was repeated for every simulated calibration data set. The resulting standard uncertainties were 0.0048 mg/L (GUM) and 0.0047 mg/L (MCM), and the MCM equal-tailed 95% coverage interval was 0.0122–0.0307 mg/L. The framework’s distinctive value is the consistent treatment of calibration measurands, matrix transfer and dual-axis error-weighted regression across both propagation methods. It provides an auditable GUM budget for routine calibration and certificate reporting, while MCM offers a verification route when repeated regression, finite-sample blank dispersion or asymmetric output intervals are important.
- 10 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (32) , 325001
A vine-copula-based method for evaluating the measurement uncertainty of airflow rate in aero-engine altitude simulation tests
In aero-engine altitude simulation tests, the inlet air flow rate is a key parameter for thrust calculation and inlet matching analysis, yet its measurement uncertainty is difficult to evaluate reliably. The input quantities exhibit significant synchronous variation and complex dependence, but the complete correlation structure is rarely obtainable in practice. Consequently, uncertainty evaluations based on the GUM often default to the independence assumption, and conventional Monte Carlo method (MCM) implementations sample each input variable independently when joint distribution information is unavailable. To address this, we propose a high-dimensional MCM approach within the GUM Supplement 1 framework that uses a vine copula to model and preserve input correlations during stochastic propagation, combined with a posterior predictive checking procedure for validation. Simulation results show that ignoring synchronous variation overestimates the standard uncertainty and coverage interval by approximately 16%, whereas the proposed method yields results nearly identical to the correlated reference values while maintaining a stable mean. Experimental data confirm that the method produces more convergent interval estimates and reveal that mean static pressure accounts for approximately 85% of the total uncertainty, identifying the primary target for optimization.
- 10 August 2026
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (32) , 325001
A vine-copula-based method for evaluating the measurement uncertainty of airflow rate in aero-engine altitude simulation tests
In aero-engine altitude simulation tests, the inlet air flow rate is a key parameter for thrust calculation and inlet matching analysis, yet its measurement uncertainty is difficult to evaluate reliably. The input quantities exhibit significant synchronous variation and complex dependence, but the complete correlation structure is rarely obtainable in practice. Consequently, uncertainty evaluations based on the GUM often default to the independence assumption, and conventional Monte Carlo method (MCM) implementations sample each input variable independently when joint distribution information is unavailable. To address this, we propose a high-dimensional MCM approach within the GUM Supplement 1 framework that uses a vine copula to model and preserve input correlations during stochastic propagation, combined with a posterior predictive checking procedure for validation. Simulation results show that ignoring synchronous variation overestimates the standard uncertainty and coverage interval by approximately 16%, whereas the proposed method yields results nearly identical to the correlated reference values while maintaining a stable mean. Experimental data confirm that the method produces more convergent interval estimates and reveal that mean static pressure accounts for approximately 85% of the total uncertainty, identifying the primary target for optimization.
- Open Access
Uncertainty Analysis and Evaluation of Gauge Measurement in Track Geometry Inspection Systems
To ensure the credibility of measurement data from the Track Geometry Detection System (TGDS) and to achieve its dynamic and accurate evaluation, this paper analyzes and assesses the sources of uncertainty in the measurement of track geometric irregularities by the track inspection system based on a calibration test bench in the laboratory. To address the issue that the track inspection system is prone to sporadic outliers under electromagnetic interference and vibration, while conventional statistical methods are sensitive to outliers and tend to overestimate the repeatability uncertainty, this paper introduces a robust statistical method based on median absolute deviation (MAD) to evaluate the uncertainty introduced by repeatability. This robust approach effectively suppresses the influence of outliers by using the median instead of the mean and absolute deviations instead of squared deviations, thereby yielding a more realistic and reliable estimate of repeatability. Taking track gauge measurement as an example for uncertainty evaluation, experimental results show that the expanded uncertainty U = 0.64 mm, which satisfies one-third of the tolerance requirement for track gauge measurement, verifying the feasibility of the proposed method. The quantitative results of uncertainty sources in this paper can be used as Type B input for uncertainty evaluation in field practical measurements, providing a reliable metrological basis for the uncertainty evaluation of track inspection systems. Meanwhile, the dynamic evaluation of track inspection systems is realized, filling the gap in their dynamic and reliable evaluation under complex interferences.
Open AccessUncertainty Analysis and Evaluation of Gauge Measurement in Track Geometry Inspection Systems
To ensure the credibility of measurement data from the Track Geometry Detection System (TGDS) and to achieve its dynamic and accurate evaluation, this paper analyzes and assesses the sources of uncertainty in the measurement of track geometric irregularities by the track inspection system based on a calibration test bench in the laboratory. To address the issue that the track inspection system is prone to sporadic outliers under electromagnetic interference and vibration, while conventional statistical methods are sensitive to outliers and tend to overestimate the repeatability uncertainty, this paper introduces a robust statistical method based on median absolute deviation (MAD) to evaluate the uncertainty introduced by repeatability. This robust approach effectively suppresses the influence of outliers by using the median instead of the mean and absolute deviations instead of squared deviations, thereby yielding a more realistic and reliable estimate of repeatability. Taking track gauge measurement as an example for uncertainty evaluation, experimental results show that the expanded uncertainty U = 0.64 mm, which satisfies one-third of the tolerance requirement for track gauge measurement, verifying the feasibility of the proposed method. The quantitative results of uncertainty sources in this paper can be used as Type B input for uncertainty evaluation in field practical measurements, providing a reliable metrological basis for the uncertainty evaluation of track inspection systems. Meanwhile, the dynamic evaluation of track inspection systems is realized, filling the gap in their dynamic and reliable evaluation under complex interferences.
- 25 September 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (9) , 095016
PSD-based parallelism measurement method of guideway and uncertainty evaluation
This study proposes a method for measuring guide rail parallelism based on position-sensitive detectors (PSDs), establishing a comprehensive uncertainty assessment framework. Parallelism errors are calculated using the public benchmark method and least squares fitting, with uncertainty components quantified via a dissemination of the value of quantity model. The reliability of the assessment is verified using the Monte Carlo method, yielding a 95% confidence interval of 10.0–14.0 μm. The innovative introduction of a conjugate prior Bayesian framework enables dynamic updating of repeatability uncertainty, reducing the expanded uncertainty by 10% (from 2.0 μm to 1.8 μm, k = 2). Comparative laser interferometer experiments demonstrate that while the interferometer offers higher precision (0.8 μm), the PSD system maintains 1.8 μm accuracy at a 33% lower cost (from ¥300 000 to ¥200 000). It supports 8 h of operation without an external power supply, offering superior portability and industrial adaptability.
- 25 September 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (9) , 095016
PSD-based parallelism measurement method of guideway and uncertainty evaluation
This study proposes a method for measuring guide rail parallelism based on position-sensitive detectors (PSDs), establishing a comprehensive uncertainty assessment framework. Parallelism errors are calculated using the public benchmark method and least squares fitting, with uncertainty components quantified via a dissemination of the value of quantity model. The reliability of the assessment is verified using the Monte Carlo method, yielding a 95% confidence interval of 10.0–14.0 μm. The innovative introduction of a conjugate prior Bayesian framework enables dynamic updating of repeatability uncertainty, reducing the expanded uncertainty by 10% (from 2.0 μm to 1.8 μm, k = 2). Comparative laser interferometer experiments demonstrate that while the interferometer offers higher precision (0.8 μm), the PSD system maintains 1.8 μm accuracy at a 33% lower cost (from ¥300 000 to ¥200 000). It supports 8 h of operation without an external power supply, offering superior portability and industrial adaptability.