Huan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Huan Liu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Donghao Xie
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China
1 shared publication - Jianghuan Shi
Ningbo Institute of Metrology and Testing, Ningbo 315048, China
1 shared publication - Mengna Zhou
Zhoushan Institute of Calibration and Testing for Quality and Technology Supervision, Zhoushan 316000, China
1 shared publication - Xianlei Chen
Zhoushan Institute of Calibration and Testing for Quality and Technology Supervision, Zhoushan 316000, China
1 shared publication - Yinbao Cheng
College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China
1 shared publication
Latest Publications
- Open Access
- 19 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (9) , 209
Calibration Method and Uncertainty Evaluation for X-Ray Fluorescence Chlorine Analyzers
X-ray fluorescence (XRF) chlorine analyzers are widely used for chlorine determination in crude oil and petroleum products. Although analytical test procedures are standardized, a calibration-oriented uncertainty framework for the analyzer itself remains insufficiently developed. This study establishes a metrological framework for relative indication error and limit of detection (LOD), supported by repeatability and linearity evaluations, and compares uncertainty propagation using the Guide to the Expression of Uncertainty in Measurement (GUM) and the Monte Carlo method (MCM). For relative indication error, residual matrix mismatch was quantified using paired isooctane-based light-oil and 75 cSt mineral-oil reference materials and incorporated with measurement repeatability and certified-value uncertainty. At 100, 300 and 500 mg/L, GUM and MCM produced closely agreeing standard uncertainties of approximately 0.0115, 0.0103 and 0.0081, respectively. For LOD, both methods used the same dual-axis error-weighted regression, accounting for uncertainties in certified concentrations and mean instrumental responses; in the MCM, the regression was repeated for every simulated calibration data set. The resulting standard uncertainties were 0.0048 mg/L (GUM) and 0.0047 mg/L (MCM), and the MCM equal-tailed 95% coverage interval was 0.0122–0.0307 mg/L. The framework’s distinctive value is the consistent treatment of calibration measurands, matrix transfer and dual-axis error-weighted regression across both propagation methods. It provides an auditable GUM budget for routine calibration and certificate reporting, while MCM offers a verification route when repeated regression, finite-sample blank dispersion or asymmetric output intervals are important.
- 19 September 2026
- Published by MDPI AG in Chemosensors
- Vol. 14 (9) , 209
Open AccessCalibration Method and Uncertainty Evaluation for X-Ray Fluorescence Chlorine Analyzers
X-ray fluorescence (XRF) chlorine analyzers are widely used for chlorine determination in crude oil and petroleum products. Although analytical test procedures are standardized, a calibration-oriented uncertainty framework for the analyzer itself remains insufficiently developed. This study establishes a metrological framework for relative indication error and limit of detection (LOD), supported by repeatability and linearity evaluations, and compares uncertainty propagation using the Guide to the Expression of Uncertainty in Measurement (GUM) and the Monte Carlo method (MCM). For relative indication error, residual matrix mismatch was quantified using paired isooctane-based light-oil and 75 cSt mineral-oil reference materials and incorporated with measurement repeatability and certified-value uncertainty. At 100, 300 and 500 mg/L, GUM and MCM produced closely agreeing standard uncertainties of approximately 0.0115, 0.0103 and 0.0081, respectively. For LOD, both methods used the same dual-axis error-weighted regression, accounting for uncertainties in certified concentrations and mean instrumental responses; in the MCM, the regression was repeated for every simulated calibration data set. The resulting standard uncertainties were 0.0048 mg/L (GUM) and 0.0047 mg/L (MCM), and the MCM equal-tailed 95% coverage interval was 0.0122–0.0307 mg/L. The framework’s distinctive value is the consistent treatment of calibration measurands, matrix transfer and dual-axis error-weighted regression across both propagation methods. It provides an auditable GUM budget for routine calibration and certificate reporting, while MCM offers a verification route when repeated regression, finite-sample blank dispersion or asymmetric output intervals are important.