Gabriel André da Silva Mendes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gabriel André da Silva Mendes has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Caio Perret
Neurosurgery, Hospital Municipal Miguel Couto, Rio de Janeiro, BRA
1 shared publication - Christian Ferreira
Phelps Hospital, Northwell Health
1 shared publication - Fernando Campos Gomes Pinto
Department of Neurosurgery, University of São Paulo, São Paulo, Brazil
1 shared publication - Gabriel Semione
Department of Medicine, University of West Santa Catarina, Joaçaba, Brazil
1 shared publication - Milene Zanella Capitanio
Faculty of Medicine, Community University of Chapecó Region, Chapecó 89809-900, Brazil
1 shared publication - Raphael Bertani
Department of Neurosurgery, University of São Paulo
1 shared publication
Latest Publications
- Open Access
- 7 October 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (10) , 2436
Shunt Dysfunction Assessment in Shunted Patients via Multiparametric Non-Invasive ICP Waveform Monitoring
Background/Objectives: Ventriculoperitoneal shunts are the standard treatment for adults diagnosed with several CSF disorders, but often face dysfunction, leading interest in non-invasive methods for diagnosing shunt issues. This study evaluates the potential of non-invasive intracranial pressure waveform monitoring (nICPw) with the brain4care (B4C) system to distinguish overdrainage, underdrainage, and normal shunt function in patients with CSF disorders. Methods: In this single-center, observational study at Hospital das Clínicas, Brazil, adult patients with CSF shunts were enrolled. Patients were categorized as Overdrainage or Underdrainage, based on clinical parameters, with an Asymptomatic group. The B4C system provided nICPw monitoring, and six parameters (including various P2/P1 ratios) were analyzed via MANOVA and ANOVA. Results: Among 30 patients (6 overdrainage, 6 underdrainage, 18 asymptomatic), five asymptomatic patients were excluded from the main analysis due to incomplete data collection, leaving 25 patients. Overdrainage patients had significantly higher ΔP2/P1 values (0.618 ± 0.210) than asymptomatic ones (0.227 ± 0.171). After excluding outliers, differences were more pronounced (H = 10.89; p < 0.01). Underdrainage patients had intermediate ΔP2/P1 values (0.387 ± 0.179) and consistently higher P2/P1 averages (>1.3). ROC analysis indicated that ΔP2/P1 > 0.3 suggested shunt dysfunction (AUC = 0.731), while the highest P2/P1 offered stronger discrimination (AUC = 0.782). A global average P2/P1 > 1.3 was linked to underdrainage, with the lowest P2/P1 values differentiating overdrainage (0.948 ± 0.321) from underdrainage (1.143 ± 0.156). Conclusions: nICPw monitoring with the B4C system demonstrated potential for detecting shunt dysfunction. Combining parameters, especially ΔP2/P1 and highest P2/P1, improves diagnostic accuracy, offering a non-invasive method that may aid in distinguishing normal from abnormal shunt function.
- 7 October 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (10) , 2436
Open AccessShunt Dysfunction Assessment in Shunted Patients via Multiparametric Non-Invasive ICP Waveform Monitoring
Background/Objectives: Ventriculoperitoneal shunts are the standard treatment for adults diagnosed with several CSF disorders, but often face dysfunction, leading interest in non-invasive methods for diagnosing shunt issues. This study evaluates the potential of non-invasive intracranial pressure waveform monitoring (nICPw) with the brain4care (B4C) system to distinguish overdrainage, underdrainage, and normal shunt function in patients with CSF disorders. Methods: In this single-center, observational study at Hospital das Clínicas, Brazil, adult patients with CSF shunts were enrolled. Patients were categorized as Overdrainage or Underdrainage, based on clinical parameters, with an Asymptomatic group. The B4C system provided nICPw monitoring, and six parameters (including various P2/P1 ratios) were analyzed via MANOVA and ANOVA. Results: Among 30 patients (6 overdrainage, 6 underdrainage, 18 asymptomatic), five asymptomatic patients were excluded from the main analysis due to incomplete data collection, leaving 25 patients. Overdrainage patients had significantly higher ΔP2/P1 values (0.618 ± 0.210) than asymptomatic ones (0.227 ± 0.171). After excluding outliers, differences were more pronounced (H = 10.89; p < 0.01). Underdrainage patients had intermediate ΔP2/P1 values (0.387 ± 0.179) and consistently higher P2/P1 averages (>1.3). ROC analysis indicated that ΔP2/P1 > 0.3 suggested shunt dysfunction (AUC = 0.731), while the highest P2/P1 offered stronger discrimination (AUC = 0.782). A global average P2/P1 > 1.3 was linked to underdrainage, with the lowest P2/P1 values differentiating overdrainage (0.948 ± 0.321) from underdrainage (1.143 ± 0.156). Conclusions: nICPw monitoring with the B4C system demonstrated potential for detecting shunt dysfunction. Combining parameters, especially ΔP2/P1 and highest P2/P1, improves diagnostic accuracy, offering a non-invasive method that may aid in distinguishing normal from abnormal shunt function.