Ian Polyzois
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ian Polyzois has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jaskaran Singh
Section of Orthopaedic Surgery, Department of Surgery, University of Manitoba, Winnipeg, Canada
1 shared publication - Michael Goytan
Max Rady College of Medicine, University of Manitoba, Winnipeg, MB, Canada
1 shared publication Sara Gustafson
Orthopaedic Innovation Centre, Winnipeg, Manitoba, Canada
1 shared publication- Thomas Robert Turgeon
Department of Surgery, University of Manitoba, Winnipeg, MB, Canada
1 shared publication Trevor Gascoyne
Orthopaedic Innovation Centre, Winnipeg, Manitoba, Canada
1 shared publication- Yunhua Luo
Department of Mechanical Engineering, University of Manitoba, Winnipeg, MB R3T 2N2, Canada
1 shared publication
Latest Publications
- Open Access
- 17 May 2026
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 58
Toward next-generation hip implants: From failure mechanisms to translational design
- 17 May 2026
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 58
Open AccessToward next-generation hip implants: From failure mechanisms to translational design
- Open Access
- 8 October 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (2) , 1259-1267
Biomechanical Impact of Splint Rods in Posterior Cervicothoracic Fixation: A Finite Element Analysis
Study Design: Basic Science Study. Objective: To determine the impact of splint rods, rod material, and rod diameter on cervicothoracic construct load bearing capacity. Methods: Finite element analysis was used to simulate 8 construct variations in a C7 vertebrectomy model with pedicle screw fixation in C5-T2. Variations included the material of rods (titanium or cobalt-chrome alloys), presence or absence of splint rods, the diameters of the splint rods (3.5 or 4.5 mm), and the size of lateral mass screws (3.5 mm or 4.0 mm). Boundary conditions replicated ASTM F1717/ISO 12189 standards. Yield load, displacement, stiffness, and stress distributions were analyzed under worst-case loading (2 cm displacement). Results: The best configuration was comprised of 3.5 mm titanium primary and splint rods, which achieved the highest load capacity of 107N and stiffness of 29.8 N/mm. The worst configuration was comprised of single 3.5 mm titanium rods, which demonstrated the lowest load capacity of 66N. Conclusions: Adding splint rods improves load bearing capacity of cervicothoracic fixation constructs. Increasing construct stiffness through increasing diameter of the rods or screws, or through change in rod alloy to cobalt chrome does not always result in an improvement of the load bearing capacity as it risks earlier failure at the bone-screw interface. Optimal construct design is a careful balance between construct stiffness and load-sharing.
- 8 October 2025
- Published by SAGE Publications in Global Spine Journal
- Vol. 16 (2) , 1259-1267
Open AccessBiomechanical Impact of Splint Rods in Posterior Cervicothoracic Fixation: A Finite Element Analysis
Study Design: Basic Science Study. Objective: To determine the impact of splint rods, rod material, and rod diameter on cervicothoracic construct load bearing capacity. Methods: Finite element analysis was used to simulate 8 construct variations in a C7 vertebrectomy model with pedicle screw fixation in C5-T2. Variations included the material of rods (titanium or cobalt-chrome alloys), presence or absence of splint rods, the diameters of the splint rods (3.5 or 4.5 mm), and the size of lateral mass screws (3.5 mm or 4.0 mm). Boundary conditions replicated ASTM F1717/ISO 12189 standards. Yield load, displacement, stiffness, and stress distributions were analyzed under worst-case loading (2 cm displacement). Results: The best configuration was comprised of 3.5 mm titanium primary and splint rods, which achieved the highest load capacity of 107N and stiffness of 29.8 N/mm. The worst configuration was comprised of single 3.5 mm titanium rods, which demonstrated the lowest load capacity of 66N. Conclusions: Adding splint rods improves load bearing capacity of cervicothoracic fixation constructs. Increasing construct stiffness through increasing diameter of the rods or screws, or through change in rod alloy to cobalt chrome does not always result in an improvement of the load bearing capacity as it risks earlier failure at the bone-screw interface. Optimal construct design is a careful balance between construct stiffness and load-sharing.