Latest Publications

  • Open Access

    Radiation Exposure Monitoring of Operating Room and Endoscopy Nurses at a Singapore Public Hospital

    by Laurentcia Arlany, Wei Tan, Jeremias C. Cillo, Leo De Vera Tugade, Ying Hao Loy, Nazeemah Binte Mohd Nor, Siok Peng Ng

    Background: Healthcare workers’ radiation safety during fluoroscopy-guided procedures remains a critical occupational health concern, particularly for nursing staff with intermittent exposure. With evolving healthcare practices, increasing procedural volumes, and technological advancements in fluoroscopic equipment, there is a need to evaluate whether continuous personal radiation dose monitoring is necessary for occasionally exposed nursing staff in operating rooms and endoscopy suites.Materials and Methods: A prospective observational study was conducted at a Singapore public hospital from July to December 2024. Eighty nurses from operating theatre and endoscopy departments were equipped with a personal dosimeter to record their dose exposure. A secure digital platform with QR code integration enabled immediate exposure logging via participants’ mobile phones, capturing 1,512 exposure data from various procedures. Radiation doses were measured bimonthly by Singapore’s National Environment Agency.Results and Discussion: Analysis revealed significant variations in the median of total exposure time across specialties, with participants specializing in vascular having the highest median exposure (4.4 hours), followed by endoscopy (2.8 hours), urology (0.3 hours), and orthopedics (0.2 hours). Despite these variations, total effective doses remained consistently low across participants from all specialties below the study period threshold of 1 mSv. The absence of a strong correlation between exposure time and effective dose suggests the effectiveness of current radiation protection measures. Cost-benefit analysis indicated potential savings of approximately $60,000 annually through reduced subscription fees, in addition to administrative man-hour savings, which would have been required for dosimeter management and dose reporting for a cohort of 315 staff.Conclusion: This study demonstrates that occasional participation in fluoroscopy-guided procedures results in minimal radiation exposure for nursing staff, supporting the discontinuation of routine radiation monitoring while maintaining periodic reviews. The findings demonstrate that current radiation protection protocols effectively maintain exposure levels well within safety limits.


  • Effective point of measurement calculations for cylindrical ionization chambers in kilovoltage x-ray beams

    by Wei Tan, Brendan Healy, Robin Hill

    Objective. Knowledge of the effective point of measurement (EPOM) of ionization chambers is needed in relative dosimetry for kilovoltage x-ray beams. This study used Monte Carlo calculations to determine EPOM of three cylindrical ionization chambers in kilovoltage x-ray beams. Approach. The EGSnrc Monte Carlo code was used for all calculations for central axis depth doses in a water phantom and in the air cavity of cylindrical ionization chambers in water. EPOM shifts were calculated for x-ray beams from 50 kVp to 300 kVp with half value layer (HVL) from 0.07 to 3.5 mm Cu, with field sizes from 5 to 15 cm diameter. Three cylindrical ionization chambers (NE 2571, Exradin A12 and PTW 30013) were realistically modelled in EGSnrc. The EPOM shift value was identified from the minimum deviation in the ratio of the dose-to-water and the dose-to-air in the chamber cavity, following published numerical methods. Main Results. EPOM shifts normalized to the radius (r) of the cylindrical chamber of the air cavity were calculated to be within 0.2 r of the central axis for HVLs between 0.5 and 3.5 mm Cu. For HVLs less than 0.5 mm Cu, the EPOM shift increased with decreasing HVL. The EPOM shift did not change significantly with field size. Once the EPOM shift is applied, residual differences between the dose-to-water depth curves and dose-to-air cavity depth curves were found to be less than 0.5% in most cases. Significance. Monte Carlo calculations confirm a zero EPOM shift for cylindrical ionization chambers in x-ray beams with HVLs greater than 0.5 mm Cu. The calculated EPOM shifts begin to deviate significantly from zero for HVLs less than 0.5 mm Cu. Current recommendations of a uniform zero EPOM shift for cylindrical ionization chambers in kilovoltage x-ray beams may be inadequate for accurate relative dosimetry in the entire medium-energy x-ray range.